DIN-rail time switches turnus Photo electric switches 42 turnus 771 turnus 772 2 ... 500 1x16 (8) A 250V~ MEMORY 20 2x10 (8) A 250V~ MEMORY 30 Voltage EAN-Code Ord.-No. ± 1h AUTO 7 x 24h 4010940 3a Lithium - Brightness sensor for surface-mounting included in the scope of delivery - Adjustable ON/OFF switching delay 0 - 100 sec - Up to 10 units (20 channels) of the types turnus 502, 771 and 772 can be extended to form a light control system with only 1 brightness sensor - With weekly time switch Sensor LF Sensor LF-flush-mounting Cap LF Assembly accessories see page 44 230 V/50-60 Hz 023263 18.19.0001.1 230 V/50-60 Hz 023270 18.19.0002.1 2–500 Lux 002671 07.02.0001.1 500-10.000 Lux 027643 07.02.0004.1 2–500 Lux 016630 07.02.0003.1 500-10.000 Lux 029166 07.02.0003.2 ON / OFF switching delay 0 ... 100 sec
Technical Data Dimensions (mm) Distributor cut-out (mm) Weight (g) approx. Connection Power consumption at 230 V~ (AC) Switching output Switch contacts AC switching capacity – Ohmic load (VDE, IEC) – Inductive load cos. ϕ 0,6 – Incandescent lamp load DC switching capacity 24 V–/60 V–/220 V– Functionality Connection type Sealable Ambient temperature: – Control unit – Brightness sensor Protection type: – Control unit – Brightness sensor Brightness sensor – Length connecting lead – Terminal capacity Photo electric switches: – Adjustment range – Hysteresis – Switching delay – Switching state display Time switch: – Memory spaces – Shortest switching time – Programmable every – Block formation of weekdays – Channel block formation – Switching state display – Summer /winter time changeover – Manual switch – Accuracy – Running reserve Dimensional drawings / circuit diagrams: turnus 771 turnus 772 45 x 52,5 x 60 46 x 54 250 285 230 V/50-60 Hz ca. 2,5 VA potential-free 1 CO 2 CO 16 A/250 V AC 10 A/250 V AC 8 A/250 V AC 2000 W ca. 800 mA/300 mA/150 mA electronic captive ± screw terminals yes –20°C ... +55°C –30°C ... +70°C IP 20 IP 65 SELV max. 100 m min. 2 x 0,75 mm 2 2 lx – 500 lx approx. factor 1.3 of engaging value adjustable: appr. 0-100s ON/0-100s OFF undelayed 20 30 1 min min fixed value – yes automatic automatic / preselection FIX ON/FIX OFF typ ± 2,5 s/day at +20°C 3 years from factory turnus 502, 771, 772 turnus 772 AC z. B. turnus 772 turnus 772 turnus 771 turnus 502 ........ Pilot unit could be: • turnus 502 • turnus 771 • turnus 772 10 units at maximum are operated as a system with a brightness sensor. Each of the units – with brightness sensor – can also be applied individually. turnus 771 AC turnus 43 DIN-rail time switches
- Page 1: Trade Program 2007 / 2008
- Page 4 and 5: DIN-rail time switches DIN-rail tim
- Page 6 and 7: DIN-rail time switches talento plus
- Page 8 and 9: DIN-rail time switches talento plus
- Page 10 and 11: DIN-rail time switches talento plus
- Page 12 and 13: DIN-rail time switches talento plus
- Page 14 and 15: DIN-rail time switches talento plus
- Page 16 and 17: DIN-rail time switches talento plus
- Page 18 and 19: DIN-rail time switches talento plus
- Page 20 and 21: DIN-rail time switches talento plus
- Page 22 and 23: DIN-rail time switches talento plus
- Page 24 and 25: DIN-rail time switches talento Over
- Page 26 and 27: DIN-rail time switches talento Digi
- Page 28 and 29: DIN-rail time switches talento Digi
- Page 30 and 31: DIN-rail time switches talento Digi
- Page 32 and 33: DIN-rail time switches talento Over
- Page 34 and 35: DIN-rail time switches talento Anal
- Page 36 and 37: DIN-rail time switches talento Anal
- Page 38 and 39: DIN-rail time switches trealux Over
- Page 40 and 41: DIN-rail time switches trealux Stai
- Page 42 and 43: DIN-rail time switches turnus Photo
- Page 46 and 47: DIN-rail time switches talento (plu
- Page 48 and 49: EIB-Range 46
- Page 50 and 51: EIB-Range EIB bus final products wi
- Page 52 and 53: EIB-Range EIB system appliances 50
- Page 54 and 55: EIB-Range EIB auxiliary clocks / Ac
- Page 56 and 57: Universal time switches Time switch
- Page 58 and 59: Universal time switches Time switch
- Page 60 and 61: Universal time switches Time switch
- Page 62 and 63: Universal time switches Time switch
- Page 64 and 65: Universal time switches Time switch
- Page 66 and 67: Universal time switches Time switch
- Page 68 and 69: Universal time switches Time switch
- Page 70 and 71: Room thermostats Room thermostats 6
- Page 72 and 73: Room thermostats famoso / thermio O
- Page 74 and 75: Room thermostats famoso Radio contr
- Page 76 and 77: Room thermostats famoso Room thermo
- Page 78 and 79: Room thermostats famoso Room thermo
- Page 80 and 81: Room thermostats thermio Thermostat
- Page 82 and 83: Plug-in & tariff time switches, Hou
- Page 84 and 85: Plug-in & tariff time switches, Hou
- Page 86 and 87: Plug-in & tariff time switches, Hou
- Page 88 and 89: Plug-in & tariff time switches, Hou
- Page 90 and 91: Plug-in & tariff time switches, Hou
- Page 92 and 93: Plug-in & tariff time switches, Hou
Technical Data<br />
Dimensions (mm)<br />
Distributor cut-out (mm)<br />
Weight (g) approx.<br />
Connection<br />
Power consumption at 230 V~ (AC)<br />
Switching output<br />
Switch contacts<br />
AC switching capacity<br />
– Ohmic load (VDE, IEC)<br />
– Inductive load cos. ϕ 0,6<br />
– Incan<strong>de</strong>scent lamp load<br />
DC switching capacity<br />
24 V–/60 V–/220 V–<br />
Functionality<br />
Connection type<br />
Sealable<br />
Ambient temperature:<br />
– Control unit<br />
– Brightness sensor<br />
Protection type:<br />
– Control unit<br />
– Brightness sensor<br />
Brightness sensor<br />
– Length connecting lead<br />
– Terminal capacity<br />
Photo electric switches:<br />
– Adjustment range<br />
– Hysteresis<br />
– Switching <strong>de</strong>lay<br />
– Switching state display<br />
Time switch:<br />
– Memory spaces<br />
– Shortest switching time<br />
– <strong>Program</strong>mable every<br />
– Block formation of weekdays<br />
– Channel block formation<br />
– Switching state display<br />
– Summer /winter time changeover<br />
– Manual switch<br />
– Accuracy<br />
– Running reserve<br />
Dimensional drawings /<br />
circuit diagrams:<br />
turnus 771 turnus 772<br />
45 x 52,5 x 60<br />
46 x 54<br />
250 285<br />
230 V/50-60 Hz<br />
ca. 2,5 VA<br />
potential-free<br />
1 CO 2 CO<br />
16 A/250 V AC 10 A/250 V AC<br />
8 A/250 V AC<br />
2000 W<br />
ca. 800 mA/300 mA/150 mA<br />
electronic<br />
captive ± screw terminals<br />
yes<br />
–20°C ... +55°C<br />
–30°C ... +70°C<br />
IP 20<br />
IP 65<br />
SELV<br />
max. 100 m<br />
min. 2 x 0,75 mm 2<br />
2 lx – 500 lx<br />
approx. factor 1.3 of engaging value<br />
adjustable: appr. 0-100s ON/0-100s OFF<br />
un<strong>de</strong>layed<br />
20 30<br />
1 min<br />
min<br />
fixed value<br />
–<br />
yes<br />
automatic<br />
automatic / preselection<br />
FIX ON/FIX OFF<br />
typ ± 2,5 s/day at +20°C<br />
3 years from factory<br />
turnus 502, 771, 772<br />
turnus 772<br />
AC<br />
z. B. turnus 772<br />
turnus 772 turnus 771 turnus 502 ........<br />
Pilot unit could be:<br />
• turnus 502<br />
• turnus 771<br />
• turnus 772<br />
10 units at maximum are operated as a system with a<br />
brightness sensor. Each of the units – with brightness<br />
sensor – can also be applied individually.<br />
turnus 771<br />
AC<br />
turnus<br />
43<br />
DIN-rail time switches