Trade Program 2007 / 2008 - graesslin.de
Trade Program 2007 / 2008 - graesslin.de Trade Program 2007 / 2008 - graesslin.de
DIN-rail time switches trealux Staircase lighting time switches 38 • Electronic • Automatic recognition of 3-line or 4-line connection 1x16 (10) A 250V~ - Adjustment range: 0.5 - 20 minutes - Immediately adjustable - Connection from below trealux 210 1x16 (10) A 250V~ trealux 610 1x16 (10) A 250V~ trealux 710 Voltage EAN-Code Ord.-No. AUTO 230 V/50-60 Hz 024789 18.13.0009.1 AUTO 230 V/50-60 Hz 023232 18.13.0007.1 AUTO 4010940 - Safety staircase lighting time switch in acc. to DIN 18015 with impulse pre-warning - Adjustment range: 0.5 – 99,5 min. - If any key is pressed for more than 2 seconds, the light remains on for 1 hour - Safety staircase lighting time switch in acc. to DIN 18015 - Pre-warning through reduced brightness / - Glow lamp only - Adjustment range: 0,5 – 99,5 min. - Half-time switching adjustable: 10 – 30 sec - If any key is pressed for more than 2 seconds, the light remains on for 1 hour, service long-term function - Input motion sensor - Diagnosis display of switch position - Hour meters - Display of switching position Assembly accessories see page 44 230 V/50-60 Hz 023225 18.13.0006.1
Technical Data Dimensions (mm) Distributor cut-out (mm) Connection Switching capacity AC – Ohmic load (VDE, IEC) cos. ϕ 1 – Inductive load cos ϕ 0,6 – Incandescent lamp load – Fluorescent lamp in DUO circuit – Fluorescent lamp, parallel compensated – Fluorescent lamp, series-compensated – EVG – KVG Switch contacts Ambient temperature Protection class Protection type Adjustment range Dim time Glow lamp load On-time Manual switch Re-triggerable Connection type Switching type Diagnosis functions Time extension Dimensional drawings / circuit diagrams: trealux 210, 610 3-wire-connection trealux 210, 610 4-wire-connection trealux 210 45 x 17,5 x 62 46 x 18 230 V/50-60 Hz 16 A / 230 V AC 10 A / 230 V AC 2300 W 20 x 2 x 58 W 20 x 58 W 40 x 58 W 5 x 20 W 1500 W 1 NO –10°C ... +55°C II IP 20 0,5 min ... 20 min – max. 50 x1 mA 100% ED yes once captive ± screw terminals automatic recognition of 3-line or 4-line connection yes no trealux 610 45 x 17,5 x 62 46 x 18 230 V/50-60 Hz 16 A/230 V AC 10 A/230 V AC 2300 W 20 x 2 x 58 W 20 x 58 W 40 x 58 W 5 x 20 W 1500 W 1 NO –10°C ... +55°C II IP 20 0,5 min ... 99,5 min – max. 50 x1 mA 100% ED yes once captive ± screw terminals automatic recognition of 3-line or 4-line connection yes yes trealux 710 45 x 35 x 60 46 x 36 230 V/50-60 Hz trealux 210, 610 trealux 710 trealux 710 3-wire-connection trealux 710 4-wire-connection trealux 8 A/230 V AC – 1200 W – – – – – 1 NO + semiconductor –15°C ... +55°C II IP 20 0,5 min ... 99,5 min 10 sec ... 30 sec max. 50 x1 mA 100% ED yes once captive ± screw terminals automatic recognition of 3-line or 4-line connection yes yes 39 DIN-rail time switches
- Page 1: Trade Program 2007 / 2008
- Page 4 and 5: DIN-rail time switches DIN-rail tim
- Page 6 and 7: DIN-rail time switches talento plus
- Page 8 and 9: DIN-rail time switches talento plus
- Page 10 and 11: DIN-rail time switches talento plus
- Page 12 and 13: DIN-rail time switches talento plus
- Page 14 and 15: DIN-rail time switches talento plus
- Page 16 and 17: DIN-rail time switches talento plus
- Page 18 and 19: DIN-rail time switches talento plus
- Page 20 and 21: DIN-rail time switches talento plus
- Page 22 and 23: DIN-rail time switches talento plus
- Page 24 and 25: DIN-rail time switches talento Over
- Page 26 and 27: DIN-rail time switches talento Digi
- Page 28 and 29: DIN-rail time switches talento Digi
- Page 30 and 31: DIN-rail time switches talento Digi
- Page 32 and 33: DIN-rail time switches talento Over
- Page 34 and 35: DIN-rail time switches talento Anal
- Page 36 and 37: DIN-rail time switches talento Anal
- Page 38 and 39: DIN-rail time switches trealux Over
- Page 42 and 43: DIN-rail time switches turnus Photo
- Page 44 and 45: DIN-rail time switches turnus Photo
- Page 46 and 47: DIN-rail time switches talento (plu
- Page 48 and 49: EIB-Range 46
- Page 50 and 51: EIB-Range EIB bus final products wi
- Page 52 and 53: EIB-Range EIB system appliances 50
- Page 54 and 55: EIB-Range EIB auxiliary clocks / Ac
- Page 56 and 57: Universal time switches Time switch
- Page 58 and 59: Universal time switches Time switch
- Page 60 and 61: Universal time switches Time switch
- Page 62 and 63: Universal time switches Time switch
- Page 64 and 65: Universal time switches Time switch
- Page 66 and 67: Universal time switches Time switch
- Page 68 and 69: Universal time switches Time switch
- Page 70 and 71: Room thermostats Room thermostats 6
- Page 72 and 73: Room thermostats famoso / thermio O
- Page 74 and 75: Room thermostats famoso Radio contr
- Page 76 and 77: Room thermostats famoso Room thermo
- Page 78 and 79: Room thermostats famoso Room thermo
- Page 80 and 81: Room thermostats thermio Thermostat
- Page 82 and 83: Plug-in & tariff time switches, Hou
- Page 84 and 85: Plug-in & tariff time switches, Hou
- Page 86 and 87: Plug-in & tariff time switches, Hou
- Page 88 and 89: Plug-in & tariff time switches, Hou
Technical Data<br />
Dimensions (mm)<br />
Distributor cut-out (mm)<br />
Connection<br />
Switching capacity AC<br />
– Ohmic load (VDE, IEC) cos. ϕ 1<br />
– Inductive load cos ϕ 0,6<br />
– Incan<strong>de</strong>scent lamp load<br />
– Fluorescent lamp in DUO circuit<br />
– Fluorescent lamp, parallel compensated<br />
– Fluorescent lamp, series-compensated<br />
– EVG<br />
– KVG<br />
Switch contacts<br />
Ambient temperature<br />
Protection class<br />
Protection type<br />
Adjustment range<br />
Dim time<br />
Glow lamp load<br />
On-time<br />
Manual switch<br />
Re-triggerable<br />
Connection type<br />
Switching type<br />
Diagnosis functions<br />
Time extension<br />
Dimensional drawings /<br />
circuit diagrams:<br />
trealux 210, 610<br />
3-wire-connection<br />
trealux 210, 610<br />
4-wire-connection<br />
trealux 210<br />
45 x 17,5 x 62<br />
46 x 18<br />
230 V/50-60 Hz<br />
16 A / 230 V AC<br />
10 A / 230 V AC<br />
2300 W<br />
20 x 2 x 58 W<br />
20 x 58 W<br />
40 x 58 W<br />
5 x 20 W<br />
1500 W<br />
1 NO<br />
–10°C ... +55°C<br />
II<br />
IP 20<br />
0,5 min ... 20 min<br />
–<br />
max. 50 x1 mA<br />
100% ED<br />
yes<br />
once<br />
captive ± screw terminals<br />
automatic recognition of<br />
3-line or 4-line connection<br />
yes<br />
no<br />
trealux 610<br />
45 x 17,5 x 62<br />
46 x 18<br />
230 V/50-60 Hz<br />
16 A/230 V AC<br />
10 A/230 V AC<br />
2300 W<br />
20 x 2 x 58 W<br />
20 x 58 W<br />
40 x 58 W<br />
5 x 20 W<br />
1500 W<br />
1 NO<br />
–10°C ... +55°C<br />
II<br />
IP 20<br />
0,5 min ... 99,5 min<br />
–<br />
max. 50 x1 mA<br />
100% ED<br />
yes<br />
once<br />
captive ± screw terminals<br />
automatic recognition of<br />
3-line or 4-line connection<br />
yes<br />
yes<br />
trealux 710<br />
45 x 35 x 60<br />
46 x 36<br />
230 V/50-60 Hz<br />
trealux 210, 610 trealux 710<br />
trealux 710<br />
3-wire-connection<br />
trealux 710<br />
4-wire-connection<br />
trealux<br />
8 A/230 V AC<br />
–<br />
1200 W<br />
–<br />
–<br />
–<br />
–<br />
–<br />
1 NO + semiconductor<br />
–15°C ... +55°C<br />
II<br />
IP 20<br />
0,5 min ... 99,5 min<br />
10 sec ... 30 sec<br />
max. 50 x1 mA<br />
100% ED<br />
yes<br />
once<br />
captive ± screw terminals<br />
automatic recognition of<br />
3-line or 4-line connection<br />
yes<br />
yes<br />
39<br />
DIN-rail time switches