Trade Program 2007 / 2008 - graesslin.de

Trade Program 2007 / 2008 - graesslin.de Trade Program 2007 / 2008 - graesslin.de

24.04.2013 Views

DIN-rail time switches trealux Staircase lighting time switches 38 • Electronic • Automatic recognition of 3-line or 4-line connection 1x16 (10) A 250V~ - Adjustment range: 0.5 - 20 minutes - Immediately adjustable - Connection from below trealux 210 1x16 (10) A 250V~ trealux 610 1x16 (10) A 250V~ trealux 710 Voltage EAN-Code Ord.-No. AUTO 230 V/50-60 Hz 024789 18.13.0009.1 AUTO 230 V/50-60 Hz 023232 18.13.0007.1 AUTO 4010940 - Safety staircase lighting time switch in acc. to DIN 18015 with impulse pre-warning - Adjustment range: 0.5 – 99,5 min. - If any key is pressed for more than 2 seconds, the light remains on for 1 hour - Safety staircase lighting time switch in acc. to DIN 18015 - Pre-warning through reduced brightness / - Glow lamp only - Adjustment range: 0,5 – 99,5 min. - Half-time switching adjustable: 10 – 30 sec - If any key is pressed for more than 2 seconds, the light remains on for 1 hour, service long-term function - Input motion sensor - Diagnosis display of switch position - Hour meters - Display of switching position Assembly accessories see page 44 230 V/50-60 Hz 023225 18.13.0006.1

Technical Data Dimensions (mm) Distributor cut-out (mm) Connection Switching capacity AC – Ohmic load (VDE, IEC) cos. ϕ 1 – Inductive load cos ϕ 0,6 – Incandescent lamp load – Fluorescent lamp in DUO circuit – Fluorescent lamp, parallel compensated – Fluorescent lamp, series-compensated – EVG – KVG Switch contacts Ambient temperature Protection class Protection type Adjustment range Dim time Glow lamp load On-time Manual switch Re-triggerable Connection type Switching type Diagnosis functions Time extension Dimensional drawings / circuit diagrams: trealux 210, 610 3-wire-connection trealux 210, 610 4-wire-connection trealux 210 45 x 17,5 x 62 46 x 18 230 V/50-60 Hz 16 A / 230 V AC 10 A / 230 V AC 2300 W 20 x 2 x 58 W 20 x 58 W 40 x 58 W 5 x 20 W 1500 W 1 NO –10°C ... +55°C II IP 20 0,5 min ... 20 min – max. 50 x1 mA 100% ED yes once captive ± screw terminals automatic recognition of 3-line or 4-line connection yes no trealux 610 45 x 17,5 x 62 46 x 18 230 V/50-60 Hz 16 A/230 V AC 10 A/230 V AC 2300 W 20 x 2 x 58 W 20 x 58 W 40 x 58 W 5 x 20 W 1500 W 1 NO –10°C ... +55°C II IP 20 0,5 min ... 99,5 min – max. 50 x1 mA 100% ED yes once captive ± screw terminals automatic recognition of 3-line or 4-line connection yes yes trealux 710 45 x 35 x 60 46 x 36 230 V/50-60 Hz trealux 210, 610 trealux 710 trealux 710 3-wire-connection trealux 710 4-wire-connection trealux 8 A/230 V AC – 1200 W – – – – – 1 NO + semiconductor –15°C ... +55°C II IP 20 0,5 min ... 99,5 min 10 sec ... 30 sec max. 50 x1 mA 100% ED yes once captive ± screw terminals automatic recognition of 3-line or 4-line connection yes yes 39 DIN-rail time switches

Technical Data<br />

Dimensions (mm)<br />

Distributor cut-out (mm)<br />

Connection<br />

Switching capacity AC<br />

– Ohmic load (VDE, IEC) cos. ϕ 1<br />

– Inductive load cos ϕ 0,6<br />

– Incan<strong>de</strong>scent lamp load<br />

– Fluorescent lamp in DUO circuit<br />

– Fluorescent lamp, parallel compensated<br />

– Fluorescent lamp, series-compensated<br />

– EVG<br />

– KVG<br />

Switch contacts<br />

Ambient temperature<br />

Protection class<br />

Protection type<br />

Adjustment range<br />

Dim time<br />

Glow lamp load<br />

On-time<br />

Manual switch<br />

Re-triggerable<br />

Connection type<br />

Switching type<br />

Diagnosis functions<br />

Time extension<br />

Dimensional drawings /<br />

circuit diagrams:<br />

trealux 210, 610<br />

3-wire-connection<br />

trealux 210, 610<br />

4-wire-connection<br />

trealux 210<br />

45 x 17,5 x 62<br />

46 x 18<br />

230 V/50-60 Hz<br />

16 A / 230 V AC<br />

10 A / 230 V AC<br />

2300 W<br />

20 x 2 x 58 W<br />

20 x 58 W<br />

40 x 58 W<br />

5 x 20 W<br />

1500 W<br />

1 NO<br />

–10°C ... +55°C<br />

II<br />

IP 20<br />

0,5 min ... 20 min<br />

–<br />

max. 50 x1 mA<br />

100% ED<br />

yes<br />

once<br />

captive ± screw terminals<br />

automatic recognition of<br />

3-line or 4-line connection<br />

yes<br />

no<br />

trealux 610<br />

45 x 17,5 x 62<br />

46 x 18<br />

230 V/50-60 Hz<br />

16 A/230 V AC<br />

10 A/230 V AC<br />

2300 W<br />

20 x 2 x 58 W<br />

20 x 58 W<br />

40 x 58 W<br />

5 x 20 W<br />

1500 W<br />

1 NO<br />

–10°C ... +55°C<br />

II<br />

IP 20<br />

0,5 min ... 99,5 min<br />

–<br />

max. 50 x1 mA<br />

100% ED<br />

yes<br />

once<br />

captive ± screw terminals<br />

automatic recognition of<br />

3-line or 4-line connection<br />

yes<br />

yes<br />

trealux 710<br />

45 x 35 x 60<br />

46 x 36<br />

230 V/50-60 Hz<br />

trealux 210, 610 trealux 710<br />

trealux 710<br />

3-wire-connection<br />

trealux 710<br />

4-wire-connection<br />

trealux<br />

8 A/230 V AC<br />

–<br />

1200 W<br />

–<br />

–<br />

–<br />

–<br />

–<br />

1 NO + semiconductor<br />

–15°C ... +55°C<br />

II<br />

IP 20<br />

0,5 min ... 99,5 min<br />

10 sec ... 30 sec<br />

max. 50 x1 mA<br />

100% ED<br />

yes<br />

once<br />

captive ± screw terminals<br />

automatic recognition of<br />

3-line or 4-line connection<br />

yes<br />

yes<br />

39<br />

DIN-rail time switches