Technical Data<br />

Dimensions (mm)<br />

Distributor cut-out (mm)<br />

Weight (g) approx.<br />

Connection<br />

Power consumption at 230 V~ (AC)<br />

Switching output<br />

Switch contacts<br />

AC switching capacity<br />

– Ohmic load (VDE, IEC)<br />

– Inductive load cos. ϕ 0,6<br />

– Incan<strong>de</strong>scent lamp load<br />

DC switching capacity<br />

24 V–/60 V–/220 V–<br />

Functionality<br />

Connection type<br />

Sealable<br />

Ambient temperature:<br />

– Control unit<br />

– Brightness sensor<br />

Protection type:<br />

– Control unit<br />

– Brightness sensor<br />

Brightness sensor:<br />

– Length connecting lead<br />

– Terminal capacity<br />

Photoelectric switches:<br />

– Adjustment range<br />

– Hysteresis<br />

– Switching <strong>de</strong>lay<br />

– Switching state display<br />

Time switch:<br />

– Memory spaces<br />

– Shortest switching time<br />

– <strong>Program</strong>mable every<br />

– Block formation of weekdays<br />

– Channel block formation<br />

– Switching state display<br />

– Summer/wintertime changeover<br />

– Manual switch<br />

– Accuracy<br />

– Running reserve<br />

Dimensional drawings /<br />

circuit diagrams:<br />

turnus 771 turnus 772<br />

45 x 52,5 x 60<br />

46 x 54<br />

250 285<br />

230 V/50-60 Hz<br />

ca. 2,5 VA<br />

potential-free<br />

1 CO 2 CO<br />

16 A/250 V AC 10 A/250 V AC<br />

8 A/250 V AC<br />

2000 W<br />

ca. 800 mA/300 mA/150 mA<br />

electronic<br />

captive ± screw terminals<br />

yes<br />

–20°C ... +55°C<br />

–30°C ... +70°C<br />

IP 20<br />

IP 65<br />

SELV<br />

max. 100 m<br />

min. 2 x 0,75 mm 2<br />

2 lx – 500 lx<br />

approx. factor 1.3 of engaging value<br />

adjustable: appr. 0-100s ON/0-100s OFF<br />

un<strong>de</strong>layed<br />

20 30<br />

1 min<br />

min<br />

fixed value<br />

–<br />

yes<br />

automatic<br />

automatic/preselection<br />

FIX ON/FIX OFF<br />

typ ± 2,5 s/day at +20°C<br />

3 years from factory<br />

e.g. turnus 772<br />

turnus 772 turnus 771 turnus 502 ........<br />

turnus 502, 771, 772 turnus 772 turnus 771<br />

AC AC<br />

TuRNuS<br />

Pilot unit could be: • turnus 502 • turnus 771 • turnus 772<br />

10 units at maximum are operated as a system with a brightness sensor.<br />

Each of the units – with brightness sensor – can also be applied individually.<br />

89<br />