Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de

Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de

24.04.2013 Views

86 TuRNuS Photoelectric switches Applications • Shop lighting • Car parking lighting • Shutters control • Advertising signs • Street lighting • Sun blinds Voltage eaN-Code 4010940 Ord.-No. Icon turnus 200 220-240 V/50-60 Hz 018986 18.17.0001.1 turnus 501 A, turnus 501 E 2…500 2…500 IP 54 turnus 501 A 230 V/50-60 Hz 023249 18.18.0001.1 – With brightness sensor surface-mounting (1) incl. in the scope of delivery turnus 501 E 230 V/50-60 Hz 024031 18.18.0006.1 – With brightness sensor, flush-mounting (2) incl. in the scope of delivery turnus 502 A 230 V/50-60 Hz 023256 18.18.0002.1 – With brightness sensor surface-mounting incl. in the scope of delivery turnus 502.1 230 V/50-60 Hz 023973 18.18.0003.1 – Additional unit without brightness sensor turnus 502 A, turnus 502.1 1x10 (2) A 250V~ 1x16 (8) A 250V~ 1x16 (8) A 250V~ 2x10 (8) A 250V~ 2x10 (8) A 250V~ – Light control system – Adjustable ON/OFF switching delay 0 – 100 sec. – Up to 10 units (20 channels) of the types turnus 502, 771 and 772 can be extended to form a light control system with only 1 brightness sensor. Assembly accessories see page 90 ON/OFF switching delay 20 ... 120 sec – With integrated brightness sensor – Surface-mounting/Outdoor-mounting ON/OFF switching delay 100 sec (fix) ON/OFF switching delay 0 ... 100 sec

Technical Data Dimensions (mm) Distributor cut-out (mm) Weight (g) approx. Connection Power consumption at 230 V~ (AC) Switching output Switch contacts AC switching capacity – Ohmic load (VDE, IEC) – Inductive load cos. ϕ 0,6 – Incandescent lamp load DC switching capacity 24 V–/60 V–/220 V– Functionality Connection type Sealable Ambient temperature: – Control unit – Brightness sensor Protection type: – Control unit – Brightness sensor Brightness sensor: – Length connecting lead – Terminal capacity Photoelectric switches: – Adjustment range – Hysteresis – Switching delay – Switching state display Dimensional drawings / circuit diagrams: turnus 200 turnus 501 turnus 502 111 x 83 x 43 – 175 220-240 V/50-60 Hz ca. 6 VA potential-free 1 NO 10 A/250 V AC 2 A/250 V AC 1200 W – electronic captive ± screw terminals – –35°C ... +60°C – IP 54 – – – – 2 lx – 2000 lx approx. factor 1.3 of engaging value 20 ... 120 sec undelayed turnus 200 45 x 17,5 x 60 46 x 18 75 230 V/50-60 Hz ca. 5 VA potential-free 1 NO 16 A/250 V AC 8 A/250 V AC 2000 W ca. 800 mA/300 mA/150 mA electronic captive ± screw terminals – –20°C ... +55°C –30°C ... +70°C IP 20 IP 65 not potential-free max. 100 m min. 0,75 mm 2 2 lx – 500 lx approx. factor 1.3 of engaging value approx. 100 s ON/100 s OFF undelayed turnus 501 45 x 52,5 x 60 46 x 54 285 230 V/50-60 Hz ca. 2,5 VA potential-free 2 changeover contacts 10 A/250 V AC 8 A/250 V AC 2000 W turnus 502 turnus 200 turnus 501 turnus 502 ca. 800 mA/300 mA/150 mA electronic captive ± screw terminals yes –20°C ... +55°C –30°C ... +70°C IP 20 IP 65 SELV max. 100 m min. 0,75 mm 2 AC TuRNuS 2 lx – 500 lx approx. factor 1.3 of engaging value adjustable: appr. 0-100s ON/0-100s OFF undelayed 87 Light control

Technical Data<br />

Dimensions (mm)<br />

Distributor cut-out (mm)<br />

Weight (g) approx.<br />

Connection<br />

Power consumption at 230 V~ (AC)<br />

Switching output<br />

Switch contacts<br />

AC switching capacity<br />

– Ohmic load (VDE, IEC)<br />

– Inductive load cos. ϕ 0,6<br />

– Incan<strong>de</strong>scent lamp load<br />

DC switching capacity<br />

24 V–/60 V–/220 V–<br />

Functionality<br />

Connection type<br />

Sealable<br />

Ambient temperature:<br />

– Control unit<br />

– Brightness sensor<br />

Protection type:<br />

– Control unit<br />

– Brightness sensor<br />

Brightness sensor:<br />

– Length connecting lead<br />

– Terminal capacity<br />

Photoelectric switches:<br />

– Adjustment range<br />

– Hysteresis<br />

– Switching <strong>de</strong>lay<br />

– Switching state display<br />

Dimensional drawings /<br />

circuit diagrams:<br />

turnus 200 turnus 501 turnus 502<br />

111 x 83 x 43<br />

–<br />

175<br />

220-240 V/50-60 Hz<br />

ca. 6 VA<br />

potential-free<br />

1 NO<br />

10 A/250 V AC<br />

2 A/250 V AC<br />

1200 W<br />

–<br />

electronic<br />

captive ± screw terminals<br />

–<br />

–35°C ... +60°C<br />

–<br />

IP 54<br />

–<br />

–<br />

–<br />

–<br />

2 lx – 2000 lx<br />

approx. factor 1.3 of engaging value<br />

20 ... 120 sec<br />

un<strong>de</strong>layed<br />

turnus 200<br />

45 x 17,5 x 60<br />

46 x 18<br />

75<br />

230 V/50-60 Hz<br />

ca. 5 VA<br />

potential-free<br />

1 NO<br />

16 A/250 V AC<br />

8 A/250 V AC<br />

2000 W<br />

ca. 800 mA/300 mA/150 mA<br />

electronic<br />

captive ± screw terminals<br />

–<br />

–20°C ... +55°C<br />

–30°C ... +70°C<br />

IP 20<br />

IP 65<br />

not potential-free<br />

max. 100 m<br />

min. 0,75 mm 2<br />

2 lx – 500 lx<br />

approx. factor 1.3 of engaging value<br />

approx. 100 s ON/100 s OFF<br />

un<strong>de</strong>layed<br />

turnus 501<br />

45 x 52,5 x 60<br />

46 x 54<br />

285<br />

230 V/50-60 Hz<br />

ca. 2,5 VA<br />

potential-free<br />

2 changeover contacts<br />

10 A/250 V AC<br />

8 A/250 V AC<br />

2000 W<br />

turnus 502<br />

turnus 200 turnus 501 turnus 502<br />

ca. 800 mA/300 mA/150 mA<br />

electronic<br />

captive ± screw terminals<br />

yes<br />

–20°C ... +55°C<br />

–30°C ... +70°C<br />

IP 20<br />

IP 65<br />

SELV<br />

max. 100 m<br />

min. 0,75 mm 2<br />

AC<br />

TuRNuS<br />

2 lx – 500 lx<br />

approx. factor 1.3 of engaging value<br />

adjustable: appr. 0-100s ON/0-100s OFF<br />

un<strong>de</strong>layed<br />

87<br />

Light control