74 FEElING Room thermostat clocks, wired connection feeling famoso 5xx 6xx 1000 • Room thermostat clocks, wired connection with weekly program • Flat and attractive design • Time and temperature control accuracy • Available in 3 modern colors: White, Anthracite, Silver • Up to 48 different time & temperature “events” per day • Various running modes • Automatic adjustment for summer- / wintertime Voltage EAN-Code 4010940 Ord.-No. Icon feeling D 101 2 x 1.5 V 039578 04.10.0001.1 white 2 x 1.5 V 039929 04.10.0002.1 anthracit 2 x 1.5 V 039936 04.10.0003.1 silver – Battery powered / Relay output – Battery LR6/AA feeling D 201 2 x 1.5 V – Lieferbar Ende 2009 white 2 x 1.5 V – Lieferbar Ende 2009 anthracit 2 x 1.5 V – Lieferbar Ende 2009 silver – Battery powered/Relay output – Battery LR6/AA – Backlighted LCD – Indoor relative humidity measurement in % – Self-learning function 1x6 (2) A 250V~ 7 x 24 h 2x MIGNON LR 6 • AA ALKALINE – Standard program individually adjustable – Holiday program up to 99 days + = 48 +5°C termo 100 230 V/50-60 Hz 012861 10.01.0001.1 Electrothermic actuator, actuator housing including position indicator, Changeover for ON/OFF without power supply – adapter set for: +32°C Valve type logo Order-No. Set (à 3 adapters) OventropM30x1.0Fine-pitchthread OV 10.01.0002.1 Danfoss RA 2000 D 17.13.0002.1 Danfoss RAV D 17.13.0009.1 Vaillant 17.13.0010.1 VELTA-Distribution panel 17.13.0007.1 Giacomini 17.13.0012.1 Applications • Central Heating • Boilers/Burners • Circulation pumps • Motorized valves Actuator without adapter to be assembled with following valve types: Valve type logo Heimeier Further combination possibilities: The components have to be purchased separately! 6:00 o´clock: 21°C 8:00 o´clock: 18°C bedroom kitchen workroom bath Oventrop M 30x1.5 OV Comap M 30x1.5 Honeywell Brauckmann Kermi Valve heating unit KERMI Böhmisch distributor entry bath floor bedroom living room loggia SBK 8:00 o´clock: 20°C 19:00 o´clock: 18°C 17:00 o´clock: 22°C 24:00 o´clock: 18°C
Technical Data Dimensions (mm) Weight (g) approx. Connection Battery life time Battery back-up Switching output Switching capacity Connection type Backlighted LCD Indoor relative humidity measurement Remote phone connection (requires additional accessories) Regulation cycles (selectable) Sensing element Ambient temperature resolution Temperature setting display range Program Frost protection Ambient temperature resolution Time setting resolution Time of day Program Temperature control accuracy Thermal gradient (heating system) Room temperature display range Programming Pre-set programs Operating temperature limits Operating humidity range Storing temperature limits Protection class Protection type According to Dimensional drawings / circuit diagrams: feeling D 101 feeling D 201 87 x 154 x 27 200 Battery 2 x 1,5V AA LR6 Alkaline 2 years (dep. on switching frequency) 10 min. (programs retained in EPROM) 1 changeover contact (potential-free) 6 (2) A 250 V AC max. 1,5mm 2 no no no 2 point, PID 100K (at 25°C) NTC 0,1ºC +5°C … +32°C (0,5°C steps) +5°C (adjustable 3°C … 7°C) 24 h or 12 h AM/PM format 1 min. 30 min. 0,5°C (20°C 3K/h) 3K/h 0ºC … +50ºC weekly program with up to 48 time and temperature level changes 4 + 1 user defined Max. 45 ºC 10% to 90% RH not condensing -20ºC ... +55ºC II IP40 EN 60730-1, EN 60730-2-7 EN 60730-2-9, EN 55014-1 EN 55014-2, EN 61000-6-2 feeling D 101 rf, D 201 rf 87 28 wiring diagram for boiler / heater 1 C 154 2 NC NO 3 Boiler / Heater 87 x 154 x 27 200 Battery 2 x 1,5V AA LR6 Alkaline 2 years (dep. on switching frequency) 10 min. (programs retained in EPROM) 1 changeover contact (potential-free) 6 (2) A 250 V AC max. 1,5mm 2 yes yes yes 2 point, PID 100K (at 25°C) NTC 0,1ºC +5°C … +32°C (0,5°C steps) +5°C (adjustable 3°C … 7°C) 24 h or 12 h AM/PM format 1 min. 30 min. 0,5°C (20°C 3K/h) 3K/h 0ºC … +50ºC weekly program with up to 48 time and temperature level changes 4 + 1 user defined Max. 45ºC 10% to 90% RH not condensing -20ºC ... +55ºC II IP40 EN 60730-1, EN 60730-2-7 EN 60730-2-9, EN 55014-1 EN 55014-2, EN 61000-6-2 wiring diagram for motorized valves N L C NC NO 1 2 3 valve termo 100 termo 100 FEElING Power supply 230 V AC 50/60 Hz Power consumption starting power 58 VA starting current 230 mA operation 2,5 W Range of functional temperature -5°C ... +50°C Range of stocking temperature -20°C ... +70°C Operating time 3 min Adjustment travel deviation 3 mm Adjustment travel compression 105 N Protection type IP 42 Protection class II Adaptor connecting nut M 30x1.5, nickel-plated Connecting line 2 x 0,5 mm 2 , 0,8 m long Factory setting reversible to OFF / ON Colour RAL 9010 64 44 75 Room thermostat clocks
- Page 23 and 24: Technical Data Dimensions H x W x D
- Page 25 and 26: Technical Data Dimensions H x W x D
- Page 27 and 28: Technical Data Dimensions H x W x D
- Page 29 and 30: Technical Data Dimensions H x W x D
- Page 31 and 32: Technical Data Dimensions H x W x D
- Page 33 and 34: Technical Data Dimensions (mm) Weig
- Page 35 and 36: TalENTo 35 Time switches
- Page 37 and 38: Technical Data Dimensions H x W x D
- Page 39 and 40: Technical Data Dimensions (mm) Weig
- Page 41 and 42: talento 211 mini talento 211 talent
- Page 43 and 44: Technical Data Dimensions H x W x D
- Page 45 and 46: Technical Data Dimensions H x W x D
- Page 47 and 48: Technical Data Dimensional drawings
- Page 49 and 50: overview digital universal time swi
- Page 51 and 52: technical Data Dimensions H x W x D
- Page 53 and 54: technical Data Dimensions H x W x D
- Page 55 and 56: technical Data Dimensions H x W x D
- Page 57 and 58: technical Data Dimensions H x W x D
- Page 59 and 60: technical Data Dimensions H x W x D
- Page 61 and 62: universal time switches / time swit
- Page 63 and 64: Grässlin room thermostats offer a
- Page 65 and 66: famoso 800 famoso 850 Room thermost
- Page 67 and 68: Technical Data Dimensions H x W x D
- Page 69 and 70: Technical Data Dimensions H x W x D
- Page 71 and 72: Technical Data Dimensions H x W x D
- Page 73: Technical Data Dimensions (mm) Weig
- Page 77 and 78: THERMIO 77 Room thermostat clocks
- Page 79 and 80: Technical Data Dimensions (mm) Weig
- Page 81 and 82: Grässlin light controls offer the
- Page 83 and 84: Overview photoelectric switches tur
- Page 85 and 86: Technical Data Dimensions (mm) Dist
- Page 87 and 88: Technical Data Dimensions (mm) Dist
- Page 89 and 90: Technical Data Dimensions (mm) Dist
- Page 91 and 92: Technical Data Dimensional drawings
- Page 93 and 94: As a pioneer for for hour meters, G
- Page 95 and 96: tip 100 S topica digi 16.30.0001.1
- Page 97 and 98: Technical data Connection Switching
- Page 99 and 100: Technical data Connection Switching
- Page 101 and 102: Technical data Dimensions (mm) Conn
- Page 103 and 104: Technical data Dimensions H x W x D
- Page 105 and 106: Taxxo 105 Plug-in time switches and
- Page 107 and 108: Grässlin offers you differentiated
- Page 109 and 110: Expertise and service for customers
- Page 111 and 112: alphabetical directory / Overview f
- Page 113 and 114: alphabetical directory / Overview f
- Page 115 and 116: numerical directory Ord.-No. EAN-Co
- Page 117 and 118: numerical directory Ord.-No. EAN-Co
- Page 119 and 120: nOTES 119 Index
- Page 121 and 122: nOTES 121 Index
- Page 123 and 124: Pictogram explanation 365 x 24 h 7
Technical Data<br />
Dimensions (mm)<br />
Weight (g) approx.<br />
Connection<br />
Battery life time<br />
Battery back-up<br />
Switching output<br />
Switching capacity<br />
Connection type<br />
Backlighted LCD<br />
Indoor relative humidity measurement<br />
Remote phone connection<br />
(requires additional accessories)<br />
Regulation cycles (selectable)<br />
Sensing element<br />
Ambient temperature resolution<br />
Temperature setting display range<br />
<strong>Program</strong><br />
Frost protection<br />
Ambient temperature resolution<br />
Time setting resolution<br />
Time of day<br />
<strong>Program</strong><br />
Temperature control accuracy<br />
Thermal gradient (heating system)<br />
Room temperature display range<br />
<strong>Program</strong>ming<br />
Pre-set programs<br />
Operating temperature limits<br />
Operating humidity range<br />
Storing temperature limits<br />
Protection class<br />
Protection type<br />
According to<br />
Dimensional drawings /<br />
circuit diagrams:<br />
feeling D 101 feeling D 201<br />
87 x 154 x 27<br />
200<br />
Battery 2 x 1,5V AA LR6 Alkaline<br />
2 years (<strong>de</strong>p. on switching frequency)<br />
10 min. (programs retained in EPROM)<br />
1 changeover contact (potential-free)<br />
6 (2) A 250 V AC<br />
max. 1,5mm 2<br />
no<br />
no<br />
no<br />
2 point, PID<br />
100K (at 25°C) NTC<br />
0,1ºC<br />
+5°C … +32°C (0,5°C steps)<br />
+5°C (adjustable 3°C … 7°C)<br />
24 h or 12 h AM/PM format<br />
1 min.<br />
30 min.<br />
0,5°C (20°C 3K/h)<br />
3K/h<br />
0ºC … +50ºC<br />
weekly program with up to 48 time<br />
and temperature level changes<br />
4 + 1 user <strong>de</strong>fined<br />
Max. 45 ºC<br />
10% to 90% RH not con<strong>de</strong>nsing<br />
-20ºC ... +55ºC<br />
II<br />
IP40<br />
EN 60730-1, EN 60730-2-7<br />
EN 60730-2-9, EN 55014-1<br />
EN 55014-2, EN 61000-6-2<br />
feeling D 101 rf, D 201 rf<br />
87<br />
28<br />
wiring diagram<br />
for boiler / heater<br />
1<br />
C<br />
154<br />
2<br />
NC<br />
NO<br />
3<br />
Boiler / Heater<br />
87 x 154 x 27<br />
200<br />
Battery 2 x 1,5V AA LR6 Alkaline<br />
2 years (<strong>de</strong>p. on switching frequency)<br />
10 min. (programs retained in EPROM)<br />
1 changeover contact (potential-free)<br />
6 (2) A 250 V AC<br />
max. 1,5mm 2<br />
yes<br />
yes<br />
yes<br />
2 point, PID<br />
100K (at 25°C) NTC<br />
0,1ºC<br />
+5°C … +32°C (0,5°C steps)<br />
+5°C (adjustable 3°C … 7°C)<br />
24 h or 12 h AM/PM format<br />
1 min.<br />
30 min.<br />
0,5°C (20°C 3K/h)<br />
3K/h<br />
0ºC … +50ºC<br />
weekly program with up to 48 time<br />
and temperature level changes<br />
4 + 1 user <strong>de</strong>fined<br />
Max. 45ºC<br />
10% to 90% RH not con<strong>de</strong>nsing<br />
-20ºC ... +55ºC<br />
II<br />
IP40<br />
EN 60730-1, EN 60730-2-7<br />
EN 60730-2-9, EN 55014-1<br />
EN 55014-2, EN 61000-6-2<br />
wiring diagram<br />
for motorized valves<br />
N L<br />
C<br />
NC<br />
NO<br />
1 2 3<br />
valve<br />
termo 100<br />
termo 100<br />
FEElING<br />
Power supply<br />
230 V AC 50/60 Hz<br />
Power consumption<br />
starting power 58 VA<br />
starting current 230 mA<br />
operation 2,5 W<br />
Range of functional temperature<br />
-5°C ... +50°C<br />
Range of stocking temperature<br />
-20°C ... +70°C<br />
Operating time<br />
3 min<br />
Adjustment travel <strong>de</strong>viation<br />
3 mm<br />
Adjustment travel compression<br />
105 N<br />
Protection type<br />
IP 42<br />
Protection class<br />
II<br />
Adaptor connecting nut<br />
M 30x1.5, nickel-plated<br />
Connecting line<br />
2 x 0,5 mm 2 , 0,8 m long<br />
Factory setting reversible to<br />
OFF / ON<br />
Colour<br />
RAL 9010<br />
64<br />
44<br />
75<br />
Room thermostat<br />
clocks