Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de
Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de
Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Technical Data<br />
Dimensions H x W x D (mm)<br />
Weight (g) approx.<br />
Operating voltage<br />
Battery lifetime<br />
Battery back-up<br />
Switching output<br />
Resistive load<br />
Connection type<br />
Backlighted LCD<br />
Indoor relative humidity measurement<br />
Outdoor temperature & relative<br />
humidity measurement<br />
(requires add. accesory)<br />
Remote phone connection<br />
(requires additional accessories)<br />
Regulation cycles (selectable)<br />
Sensing element<br />
Ambient temperature resolution<br />
Temperature setting display range<br />
– <strong>Program</strong><br />
– Frost protection<br />
Time display<br />
Time setting resolution<br />
– Time of day<br />
– <strong>Program</strong><br />
Temperature control accuracy<br />
Thermal gradient (heating system)<br />
Room temperature display range<br />
<strong>Program</strong>ming<br />
Pre-set programs<br />
Output signal<br />
RF signal<br />
RF signal range<br />
Coding<br />
Power transmission<br />
(2 walls + 1 ceiling)<br />
Operating humidity range<br />
Storing temperature limits<br />
Protection class<br />
Protection type<br />
According to<br />
Dimensional drawings /circuit diagrams:<br />
feeling D 101 rf, D 201 rf<br />
154<br />
87<br />
28<br />
feeling D 101 rf feeling D 201 rf<br />
87 x 154 x 27<br />
200<br />
Battery 2 x 1,5 V AA LR6 Alkaline<br />
2 year (<strong>de</strong>p. on switching frequency)<br />
>10 min. (programs retained in EEPROM)<br />
<strong>de</strong>pending on receiver type see p. 70<br />
<strong>de</strong>pending on receiver type see p. 70<br />
<strong>de</strong>pending on receiver type see p. 70<br />
no<br />
no<br />
no<br />
no<br />
2 points, PID<br />
100K (at 25ºC) NTC<br />
0,1ºC<br />
+5ºC … +32ºC (0,5ºC steps)<br />
+5ºC (adjustable +3ºC … +7ºC)<br />
24 h or 12 h AM/PM format<br />
1 min.<br />
30 min.<br />
0,5K (20°C 3K/h)<br />
3K/h<br />
0ºC … +50ºC<br />
weekly program with up to 48 time<br />
and temperature level changes<br />
4 + 1 user <strong>de</strong>fined<br />
RF signal<br />
868,3 MHz<br />
Insi<strong>de</strong> buildings 30 m<br />
(2 walls + 1 ceiling)<br />
> 16,8 Mio.<br />
< 1mW<br />
Max. 45ºC<br />
10 % to 90 % RH not con<strong>de</strong>nsing<br />
-20ºC ... +55ºC<br />
II<br />
IP40<br />
EN 60730-1, EN 60730-2-7<br />
EN 60730-2-9, EN 55014-1<br />
EN 55014-2, EN 61000-6-2<br />
ETSI EN 300 220-1<br />
ETSI EN 300 220-3<br />
ETSI EN 301 489-3<br />
87 x 154 x 27<br />
200<br />
Battery 2 x 1,5 V AA LR6 Alkaline<br />
2 year (<strong>de</strong>p. on switching frequency)<br />
>10 min. (programs retained in EEPROM)<br />
<strong>de</strong>pending on receiver type see p. 70<br />
<strong>de</strong>pending on receiver type see p. 70<br />
<strong>de</strong>pending on receiver type see p. 70<br />
yes<br />
yes<br />
yes<br />
yes<br />
2 points, PID, self-learning<br />
100K (at 25°C) NTC<br />
0,1°C<br />
+5ºC … +32ºC (0,5ºC steps)<br />
+5ºC (adjustable +3ºC … +7ºC)<br />
24 h or 12 h AM/PM format<br />
1 min.<br />
30 min.<br />
0,5°C (20°C 3K/h)<br />
3K/h<br />
0°C … +50°C<br />
weekly program with up to 48 time<br />
and temperature level changes<br />
4 + 1 user <strong>de</strong>fined<br />
RF signal<br />
868,3 MHz (bi-directional)<br />
Insi<strong>de</strong> buildings 30 m<br />
(2 walls + 1 ceiling)<br />
> 16,8 Mio.<br />
< 1mW<br />
Max. 45°C<br />
10 % to 90 % RH not con<strong>de</strong>nsing<br />
-20°C ... +55°C<br />
II<br />
IP40<br />
EN 60730-1, EN 60730-2-7<br />
EN 60730-2-9, EN 55014-1<br />
EN 55014-2, EN 61000-6-2<br />
ETSI EN 300 220-1<br />
ETSI EN 300 220-3<br />
ETSI EN 301 489-3<br />
FEElING<br />
67<br />
Room thermostat<br />
clocks