24.04.2013 Views

Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de

Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de

Trade Program 2009/2010 inTelligenT swiTching ... - Graesslin.de

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical Data<br />

Dimensions H x W x D (mm)<br />

Weight (g) approx.<br />

Operating voltage<br />

Battery lifetime<br />

Battery back-up<br />

Switching output<br />

Resistive load<br />

Connection type<br />

Backlighted LCD<br />

Indoor relative humidity measurement<br />

Outdoor temperature & relative<br />

humidity measurement<br />

(requires add. accesory)<br />

Remote phone connection<br />

(requires additional accessories)<br />

Regulation cycles (selectable)<br />

Sensing element<br />

Ambient temperature resolution<br />

Temperature setting display range<br />

– <strong>Program</strong><br />

– Frost protection<br />

Time display<br />

Time setting resolution<br />

– Time of day<br />

– <strong>Program</strong><br />

Temperature control accuracy<br />

Thermal gradient (heating system)<br />

Room temperature display range<br />

<strong>Program</strong>ming<br />

Pre-set programs<br />

Output signal<br />

RF signal<br />

RF signal range<br />

Coding<br />

Power transmission<br />

(2 walls + 1 ceiling)<br />

Operating humidity range<br />

Storing temperature limits<br />

Protection class<br />

Protection type<br />

According to<br />

Dimensional drawings /circuit diagrams:<br />

feeling D 101 rf, D 201 rf<br />

154<br />

87<br />

28<br />

feeling D 101 rf feeling D 201 rf<br />

87 x 154 x 27<br />

200<br />

Battery 2 x 1,5 V AA LR6 Alkaline<br />

2 year (<strong>de</strong>p. on switching frequency)<br />

>10 min. (programs retained in EEPROM)<br />

<strong>de</strong>pending on receiver type see p. 70<br />

<strong>de</strong>pending on receiver type see p. 70<br />

<strong>de</strong>pending on receiver type see p. 70<br />

no<br />

no<br />

no<br />

no<br />

2 points, PID<br />

100K (at 25ºC) NTC<br />

0,1ºC<br />

+5ºC … +32ºC (0,5ºC steps)<br />

+5ºC (adjustable +3ºC … +7ºC)<br />

24 h or 12 h AM/PM format<br />

1 min.<br />

30 min.<br />

0,5K (20°C 3K/h)<br />

3K/h<br />

0ºC … +50ºC<br />

weekly program with up to 48 time<br />

and temperature level changes<br />

4 + 1 user <strong>de</strong>fined<br />

RF signal<br />

868,3 MHz<br />

Insi<strong>de</strong> buildings 30 m<br />

(2 walls + 1 ceiling)<br />

> 16,8 Mio.<br />

< 1mW<br />

Max. 45ºC<br />

10 % to 90 % RH not con<strong>de</strong>nsing<br />

-20ºC ... +55ºC<br />

II<br />

IP40<br />

EN 60730-1, EN 60730-2-7<br />

EN 60730-2-9, EN 55014-1<br />

EN 55014-2, EN 61000-6-2<br />

ETSI EN 300 220-1<br />

ETSI EN 300 220-3<br />

ETSI EN 301 489-3<br />

87 x 154 x 27<br />

200<br />

Battery 2 x 1,5 V AA LR6 Alkaline<br />

2 year (<strong>de</strong>p. on switching frequency)<br />

>10 min. (programs retained in EEPROM)<br />

<strong>de</strong>pending on receiver type see p. 70<br />

<strong>de</strong>pending on receiver type see p. 70<br />

<strong>de</strong>pending on receiver type see p. 70<br />

yes<br />

yes<br />

yes<br />

yes<br />

2 points, PID, self-learning<br />

100K (at 25°C) NTC<br />

0,1°C<br />

+5ºC … +32ºC (0,5ºC steps)<br />

+5ºC (adjustable +3ºC … +7ºC)<br />

24 h or 12 h AM/PM format<br />

1 min.<br />

30 min.<br />

0,5°C (20°C 3K/h)<br />

3K/h<br />

0°C … +50°C<br />

weekly program with up to 48 time<br />

and temperature level changes<br />

4 + 1 user <strong>de</strong>fined<br />

RF signal<br />

868,3 MHz (bi-directional)<br />

Insi<strong>de</strong> buildings 30 m<br />

(2 walls + 1 ceiling)<br />

> 16,8 Mio.<br />

< 1mW<br />

Max. 45°C<br />

10 % to 90 % RH not con<strong>de</strong>nsing<br />

-20°C ... +55°C<br />

II<br />

IP40<br />

EN 60730-1, EN 60730-2-7<br />

EN 60730-2-9, EN 55014-1<br />

EN 55014-2, EN 61000-6-2<br />

ETSI EN 300 220-1<br />

ETSI EN 300 220-3<br />

ETSI EN 301 489-3<br />

FEElING<br />

67<br />

Room thermostat<br />

clocks

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!