50 tactic analog universal time switches • Battery backup with quartz version • Daily or weekly program • Improved dust protection • 1 channel • 16 A/250 V AC switching capacity • Surface, fl ush and DIN-rail mounting voltage EaN-code 4010940 ord.-No. icon tactic 111.1 220-240 V/50 Hz 003975 01.80.0001.1 tactic 171.1 220-240 V/50 Hz 003982 01.80.0002.1 tactic 111.1, tactic 171.1 SYNCHRON tactic 211.1 230 V AC/130 V DC 004019 02.80.0001.1 tactic 271.1 230 V AC/130 V DC 004026 02.80.0002.1 tactic 211.1, tactic 271.1 QUARTZ Accessories see page 61 ACCU 150 h applications • Machinery control • Heating systems control • Devices, motors and pumps controls 1x16 (8) A 250V~ 1x16 (8) A 250V~ 1x16 (8) A 250V~ 1x16 (8) A 250V~ 24 h 7 x 24 h 24 h 7 x 24 h
technical Data Dimensions H x W x D (mm) Cut out (mm) Dimensions of front frame (mm) Fitting depth (mm) Weight (g) approx. Nominal voltage Power consumption Current output – Relay Switching current AC – Resistive load (VDE, IEC) – Resistive load (UL) – Inductive load cos. ϕ 0,6 – Incandescent lamp load Minimum switching current AC Minimum switching current DC Battery backup Battery charge time Operation accuracy Ambient temperature Security level for fitting according to instructions Shortest switching time – Daily program – Weekly program Shortest switching interval – Daily program – Weekly program Automatic override Clock face Sealing According to Type of connection Dimensional drawings / circuit diagrams: tactic 111.1 tactic 171.1 72 x 72 x 34,5 68 x 68 72 x 72 39,5 155 220-240 V AC/50 Hz 1 VA at 230 V AC 1 changeover contact, potential-free 16 A/250 V AC 21 A/250 V AC 8 A/250 V AC 1300 W 100 mA/20 V AC 100 mA/20 V DC – – synchronal to network –20°C ... +55°C II 15 min 2 h 15 min 2 h yes yes possible EN 60730-1 EN 60730-2-7 flat DIN 6.3 mm Fitted socket (Accessories) tactic 111.1, 171.1, 211.1, 271.1 tactic 111.1, 171.1, 211.1, 271.1 OFF tactic 211.1 tactic 271.1 72 x 72 x 34,5 68 x 68 72 x 72 39,5 165 230 V AC/130 V DC 2 VA at 230 V AC 1 changeover contact, potential-free 16 A/250 V AC 21 A/250 V AC 8 A/250 V AC 1300 W 100 mA/20 V AC 100 mA/20 V DC 150 h 70 h typ ± 1,5s/day at 20°C –20°C ... +55°C II 15 min 2 h 15 min 2 h yes yes possible EN 60730-1 EN 60730-2-7 flat DIN 6.3 mm Fitted socket (Accessories) Tappet position tactic manual switch ON Auto OFF tactic 51 Time switches
- Page 1: Trade Program 2009/2010 inTelligenT
- Page 5 and 6: intelligent products for efficient
- Page 7 and 8: Programmed for success. FeelinG - G
- Page 9 and 10: Grässlin products stand for highes
- Page 11 and 12: Light control Efficient solutions f
- Page 13 and 14: Grässlin’s state-of-the-art time
- Page 15 and 16: talento 791 plus talento 792 plus 1
- Page 17 and 18: talento plus Top ... the annual tim
- Page 19 and 20: Convenient communication • LAN mo
- Page 21 and 22: Clear menu navigation The menu tech
- Page 23 and 24: Technical Data Dimensions H x W x D
- Page 25 and 26: Technical Data Dimensions H x W x D
- Page 27 and 28: Technical Data Dimensions H x W x D
- Page 29 and 30: Technical Data Dimensions H x W x D
- Page 31 and 32: Technical Data Dimensions H x W x D
- Page 33 and 34: Technical Data Dimensions (mm) Weig
- Page 35 and 36: TalENTo 35 Time switches
- Page 37 and 38: Technical Data Dimensions H x W x D
- Page 39 and 40: Technical Data Dimensions (mm) Weig
- Page 41 and 42: talento 211 mini talento 211 talent
- Page 43 and 44: Technical Data Dimensions H x W x D
- Page 45 and 46: Technical Data Dimensions H x W x D
- Page 47 and 48: Technical Data Dimensional drawings
- Page 49: overview digital universal time swi
- Page 53 and 54: technical Data Dimensions H x W x D
- Page 55 and 56: technical Data Dimensions H x W x D
- Page 57 and 58: technical Data Dimensions H x W x D
- Page 59 and 60: technical Data Dimensions H x W x D
- Page 61 and 62: universal time switches / time swit
- Page 63 and 64: Grässlin room thermostats offer a
- Page 65 and 66: famoso 800 famoso 850 Room thermost
- Page 67 and 68: Technical Data Dimensions H x W x D
- Page 69 and 70: Technical Data Dimensions H x W x D
- Page 71 and 72: Technical Data Dimensions H x W x D
- Page 73 and 74: Technical Data Dimensions (mm) Weig
- Page 75 and 76: Technical Data Dimensions (mm) Weig
- Page 77 and 78: THERMIO 77 Room thermostat clocks
- Page 79 and 80: Technical Data Dimensions (mm) Weig
- Page 81 and 82: Grässlin light controls offer the
- Page 83 and 84: Overview photoelectric switches tur
- Page 85 and 86: Technical Data Dimensions (mm) Dist
- Page 87 and 88: Technical Data Dimensions (mm) Dist
- Page 89 and 90: Technical Data Dimensions (mm) Dist
- Page 91 and 92: Technical Data Dimensional drawings
- Page 93 and 94: As a pioneer for for hour meters, G
- Page 95 and 96: tip 100 S topica digi 16.30.0001.1
- Page 97 and 98: Technical data Connection Switching
- Page 99 and 100: Technical data Connection Switching
technical Data<br />
Dimensions H x W x D (mm)<br />
Cut out (mm)<br />
Dimensions of front frame (mm)<br />
Fitting <strong>de</strong>pth (mm)<br />
Weight (g) approx.<br />
Nominal voltage<br />
Power consumption<br />
Current output<br />
– Relay<br />
Switching current AC<br />
– Resistive load (VDE, IEC)<br />
– Resistive load (UL)<br />
– Inductive load cos. ϕ 0,6<br />
– Incan<strong>de</strong>scent lamp load<br />
Minimum switching current AC<br />
Minimum switching current DC<br />
Battery backup<br />
Battery charge time<br />
Operation accuracy<br />
Ambient temperature<br />
Security level<br />
for fitting according to instructions<br />
Shortest switching time<br />
– Daily program<br />
– Weekly program<br />
Shortest switching interval<br />
– Daily program<br />
– Weekly program<br />
Automatic overri<strong>de</strong><br />
Clock face<br />
Sealing<br />
According to<br />
Type of connection<br />
Dimensional drawings /<br />
circuit diagrams:<br />
tactic 111.1<br />
tactic 171.1<br />
72 x 72 x 34,5<br />
68 x 68<br />
72 x 72<br />
39,5<br />
155<br />
220-240 V AC/50 Hz<br />
1 VA at 230 V AC<br />
1 changeover contact,<br />
potential-free<br />
16 A/250 V AC<br />
21 A/250 V AC<br />
8 A/250 V AC<br />
1300 W<br />
100 mA/20 V AC<br />
100 mA/20 V DC<br />
–<br />
–<br />
synchronal to network<br />
–20°C ... +55°C<br />
II<br />
15 min<br />
2 h<br />
15 min<br />
2 h<br />
yes<br />
yes<br />
possible<br />
EN 60730-1<br />
EN 60730-2-7<br />
flat DIN 6.3 mm<br />
Fitted socket (Accessories)<br />
tactic 111.1, 171.1, 211.1, 271.1<br />
tactic 111.1, 171.1, 211.1, 271.1<br />
OFF<br />
tactic 211.1<br />
tactic 271.1<br />
72 x 72 x 34,5<br />
68 x 68<br />
72 x 72<br />
39,5<br />
165<br />
230 V AC/130 V DC<br />
2 VA at 230 V AC<br />
1 changeover contact,<br />
potential-free<br />
16 A/250 V AC<br />
21 A/250 V AC<br />
8 A/250 V AC<br />
1300 W<br />
100 mA/20 V AC<br />
100 mA/20 V DC<br />
150 h<br />
70 h<br />
typ ± 1,5s/day at 20°C<br />
–20°C ... +55°C<br />
II<br />
15 min<br />
2 h<br />
15 min<br />
2 h<br />
yes<br />
yes<br />
possible<br />
EN 60730-1<br />
EN 60730-2-7<br />
flat DIN 6.3 mm<br />
Fitted socket (Accessories)<br />
Tappet position<br />
tactic manual switch<br />
ON<br />
Auto<br />
OFF<br />
tactic<br />
51<br />
Time switches