48 fm1 analog time switch modules Features • Battery backup with quartz version • Daily or weekly program • 1 Channel • 16 A/250 V AC switching capacity • Compatible fi tting with digital time switch modules FMD • Only for fitted mounting‘ Voltage ean-code 4010940 ord.-no. Fm/1 STuZH 220-240 V / 50 Hz 000264 01.76.0088.1 Fm/1 SWuZH 220-240 V / 50 Hz 000271 01.76.0089.1 Fm/1 STuZH, Fm/1 SWuZH SYNCHRON Fm/1 QRTuZH 230 V AC / 130 V DC 000592 02.76.0075.1 Fm/1 QRWuZH 230 V AC / 130 V DC 000608 02.76.0076.1 Fm/1 QRTuZH, Fm/1 QRWuZH QUARTZ Accessories see page 57 ACCU 150 h Applications • Appliances control • Gas boilers control • Devices, motors and pumps controls 1x16 (8) A 250 V~ 1x16 (8) A 250 V~ 1x16 (8) A 250 V~ 1x16 (8) A 250 V~ 24 h 7 x 24 h 24 h 7 x 24 h
Technical data Dimensions H x W x D (mm) 60 x 60 x 32 60 x 60 x 32 Cut out (mm) ø 64 ø 64 Fitting depth (mm) 21 21 Weight (g) approx. 75 75 Nominal voltage 220-240 V AC / 50 Hz 230 V AC / 130 V DC Power consumption Current output 1 VA at 220 V AC 2 VA at 220 V AC – relay changeover contact, potential-free changeover contact, potential-free Switching current AC – ohmic load (VDE, IEC) – ohmic load (UL) – inductive load cos. φ 0.6 – incandescent lamp load 16 A / 250 V AC 21 A / 250 V AC 8 A / 250 V AC 1350 W FM/1 S, FM/1 Q FM/1 S, FM/1 Q OFF 54 21 60 32 5 4 ø 3,4 m~ 3 2 1 ø 62 16 A / 250 V AC 21 A / 250 V AC 8 A / 250 V AC 1350 W Minimum switching current AC 100 mA / 20 V AC 100 mA / 20 V AC Minimum switching current DC 100 mA / 20 V DC 100 mA / 20 V DC Power reserve – 150 h Battery charge time – 70 h Accuracy synchronic to network typ ± 1,5 sec./day at +20°C Ambient temperature -40°C ... +85°C -20°C ... +55°C Protection class II II Shortest switching time – daily program – weekly program Shortest switching interval – daily program – weekly program 15 min. 2 h 15 min. 2 h 15 min. 2 h 15 min. 2 h Manual switch automatic / fix ON/OFF automatic / fix ON/OFF Clock face yes yes According to EN 60730-1 EN 60730-2-7 EN 60730-1 EN 60730-2-7 Type of connection Fitted socket DIN 6,3 Fitted socket DIN 6,3 dimensional drawings / circuit diagrams: Fm/1 S Fm/1 Q Tappet position ON Manual switch ON Auto OFF 5 4 5 4 5 4 OFF m~ 3 2 1 m~ 3 2 1 5 4 3 m~ 3 2 1 m~ 2 1 fm1 49 Time switches
- Page 1 and 2: Grässlin GmbH Bundesstraße 36 D-7
- Page 3: what options can we offer you to op
- Page 6 and 7: 6 feeling Grässlin keeps its promi
- Page 8 and 9: 8 Tested quality down to the finest
- Page 10 and 11: 10 Table of contents Time switches
- Page 12 and 13: 12 Time swiTches din-rail time swit
- Page 14 and 15: 14 TalenTo Plus overview digital di
- Page 16 and 17: 16 TalenTo Plus sTandard - medium e
- Page 18 and 19: 18 TalenTo Plus ToP easy installati
- Page 20 and 21: 20 TalenTo Plus clear menu navigati
- Page 22 and 23: 22 TalenTo Plus - sTandard digital
- Page 24 and 25: 24 TalenTo Plus - medium digital di
- Page 26 and 27: 26 TalenTo Plus - medium digital di
- Page 28 and 29: 28 TalenTo Plus - medium digital di
- Page 30 and 31: 30 TalenTo Plus - ToP digital din-r
- Page 32 and 33: 32 TalenTo Plus - ToP digital din-r
- Page 34 and 35: 34 TalenTo Plus digital din-rail ti
- Page 36 and 37: 36 TalenTo overview analog din-rail
- Page 38 and 39: 38 TalenTo analog din-rail time swi
- Page 40 and 41: 40 TalenTo analog din-rail time swi
- Page 42 and 43: 42 TalenTo / TalenTo Plus accessori
- Page 44 and 45: 44 TacTic / fm overview analog univ
- Page 46 and 47: 46 TacTic analog universal time swi
- Page 50 and 51: 50 TacTic Plus digital universal ti
- Page 52 and 53: 52 fmd digital time switch modules
- Page 54 and 55: 54 emd digital time switch modules
- Page 56 and 57: 56 Phase-ouT models / BackuP deVice
- Page 58 and 59: 58 room ThermosTaT clocks room ther
- Page 60 and 61: 60 feeling, famoso overview wireles
- Page 62 and 63: 62 feeling wireless room thermostat
- Page 64 and 65: 64 famoso wireless room thermostat
- Page 66 and 67: 66 feeling, famoso wireless room th
- Page 68 and 69: 68 feeling room thermostat clocks,
- Page 70 and 71: 70 famoso room thermostat clocks, w
- Page 72 and 73: 72 Thermio overview thermostats the
- Page 74 and 75: 74 Thermio Thermostats Features •
- Page 76 and 77: 76 Thermio Thermostats Features •
- Page 78 and 79: 78 lighT conTrol staircase lighting
- Page 80 and 81: 80 Trealux overview staircase light
- Page 82 and 83: 82 Trealux staircase lighting time
- Page 84 and 85: 84 Turnus Photoelectric switches Ap
- Page 86 and 87: 86 Turnus Photoelectric switches di
- Page 88 and 89: 88 Trealux, Turnus accessories - di
- Page 90 and 91: 90 Plug-in Time swiTches, auTomaTic
- Page 92 and 93: 92 ToPica overview plug-in time swi
- Page 94 and 95: 94 ToPica Plug-in time switches App
- Page 96 and 97: 96 rondomaTic / Tasu automatic fish
Technical data<br />
Dimensions H x W x D (mm) 60 x 60 x 32 60 x 60 x 32<br />
Cut out (mm) ø 64 ø 64<br />
Fitting <strong>de</strong>pth (mm) 21 21<br />
Weight (g) approx. 75 75<br />
Nominal voltage 220-240 V AC / 50 Hz 230 V AC / 130 V DC<br />
Power consumption<br />
Current output<br />
1 VA at 220 V AC 2 VA at 220 V AC<br />
– relay<br />
changeover contact, potential-free changeover contact, potential-free<br />
Switching current AC<br />
– ohmic load (VDE, IEC)<br />
– ohmic load (UL)<br />
– inductive load cos. φ 0.6<br />
– incan<strong>de</strong>scent lamp load<br />
16 A / 250 V AC<br />
21 A / 250 V AC<br />
8 A / 250 V AC<br />
1350 W<br />
FM/1 S, FM/1 Q<br />
FM/1 S, FM/1 Q<br />
OFF<br />
54 21<br />
60 32<br />
5 4<br />
ø 3,4<br />
m~<br />
3 2 1<br />
ø 62<br />
16 A / 250 V AC<br />
21 A / 250 V AC<br />
8 A / 250 V AC<br />
1350 W<br />
Minimum switching current AC 100 mA / 20 V AC 100 mA / 20 V AC<br />
Minimum switching current DC 100 mA / 20 V DC 100 mA / 20 V DC<br />
Power reserve – 150 h<br />
Battery charge time – 70 h<br />
Accuracy synchronic to network typ ± 1,5 sec./day at +20°C<br />
Ambient temperature -40°C ... +85°C -20°C ... +55°C<br />
Protection class II II<br />
Shortest switching time<br />
– daily program<br />
– weekly program<br />
Shortest switching interval<br />
– daily program<br />
– weekly program<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF<br />
Clock face yes yes<br />
According to EN 60730-1<br />
EN 60730-2-7<br />
EN 60730-1<br />
EN 60730-2-7<br />
Type of connection Fitted socket DIN 6,3 Fitted socket DIN 6,3<br />
dimensional drawings /<br />
circuit diagrams:<br />
Fm/1 S Fm/1 Q<br />
Tappet position<br />
ON<br />
Manual switch<br />
ON<br />
Auto<br />
OFF<br />
5 4<br />
5 4<br />
5 4<br />
OFF<br />
m~<br />
3 2 1<br />
m~<br />
3 2 1 5 4 3<br />
m~<br />
3 2 1<br />
m~<br />
2 1<br />
fm1<br />
49<br />
Time switches