Trade Program 2011/2012 inTelligenT swiTching ... - Graesslin.de
Trade Program 2011/2012 inTelligenT swiTching ... - Graesslin.de
Trade Program 2011/2012 inTelligenT swiTching ... - Graesslin.de
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Grässlin GmbH<br />
Bun<strong>de</strong>sstraße 36<br />
D-78112 St. Georgen / Schw.<br />
Tel: +49 (0) 7724 / 933-0<br />
Fax: +49 (0) 7724 / 933-240<br />
www.graesslin.<strong>de</strong><br />
info@graesslin.<strong>de</strong><br />
Technical specifications and other information are subject to change without notice · 82.01.1294.7 <strong>Tra<strong>de</strong></strong> <strong>Program</strong> <strong>2011</strong>/<strong>2012</strong><br />
<strong>Tra<strong>de</strong></strong> <strong>Program</strong> <strong>2011</strong>/<strong>2012</strong><br />
<strong>Tra<strong>de</strong></strong> <strong>Program</strong> <strong>2011</strong>/<strong>2012</strong><br />
<strong>inTelligenT</strong> <strong>swiTching</strong> Technology<br />
for Time, TemPeraTure and lighT.
Pictogram explanation<br />
365 x 24 h<br />
7 x 24 h<br />
24 h<br />
± 1 h<br />
AUTO<br />
6a<br />
Lithium<br />
ACCU<br />
150 h<br />
2<br />
ACCU<br />
3a<br />
sec./min./h/d<br />
ASTRO<br />
Short time program<br />
1 h ± 90 min.<br />
24 h / 15 min.<br />
MEMORY<br />
50<br />
C-MOS<br />
0,1 mA<br />
2x16 (8) A<br />
250 V~<br />
± 1 h<br />
Fix ON/OFF<br />
Annual, weekly<br />
and daily program<br />
Weekly and<br />
daily program<br />
Daily program<br />
Daily program /<br />
15 min switching<br />
interval<br />
Memory spaces<br />
Switching capacity<br />
Switching capacity<br />
Automatic summer<br />
time/winter time<br />
changeover<br />
Manual summer<br />
time / winter time<br />
changeover<br />
Switching state<br />
Fix ON/OFF<br />
Switching<br />
preselection<br />
(Overri<strong>de</strong>)<br />
Fix ON /<br />
timer handling /<br />
Fix OFF<br />
Fix ON / clock mo<strong>de</strong><br />
Running reserve<br />
Lithium-battery<br />
Running reserve<br />
External input<br />
for countdown or<br />
overri<strong>de</strong><br />
IR<br />
DCF 77<br />
DCF 77<br />
GPS<br />
00099,9 h<br />
IR<br />
RJ45<br />
IP 54<br />
IR<br />
IR<br />
Running reserve<br />
Impulse/cycle<br />
Automatic <strong>de</strong>termination<br />
of the times for<br />
sunrise and sunset<br />
Offset ASTRO<br />
External input<br />
Radio interface<br />
DCF 77<br />
Radio interface<br />
DCF 77 and GPS<br />
2-wire connection<br />
Hour meter<br />
IR-Receiver<br />
RJ45 Interface<br />
Protection type<br />
Download programs<br />
from handheld<br />
programming <strong>de</strong>vice<br />
Upload programs from<br />
handheld programming<br />
<strong>de</strong>vice<br />
Portable cover<br />
Digital dsplay<br />
1 x<br />
FUNCTION<br />
current temp.<br />
SYNCHRON<br />
COUNTDOWN<br />
0099,9<br />
Fix ... 99x24h<br />
LUX<br />
QUARTZ<br />
RANDOM<br />
3x<br />
LAN<br />
PLC<br />
3<br />
4<br />
AUTO<br />
08:30<br />
2...2000<br />
One time action<br />
Current temperature<br />
Synchron drive<br />
Quartz drive<br />
Countdown timer<br />
Impulse counter<br />
LAN communication<br />
Powerline (PLC)<br />
communication<br />
Random generator<br />
Holiday program<br />
Date program<br />
Staircase lighting<br />
time switches<br />
Staircase lighting time<br />
switches with impulse<br />
pre-warning<br />
3- and 4-wire<br />
connection<br />
Photoelectric<br />
switches,<br />
process and time<br />
controlled<br />
Photoelectric<br />
switches,<br />
process controlled<br />
Adjustment range Lux<br />
+5°C +32°C<br />
ED<br />
PicTograms<br />
1 2 3<br />
ELECTRON.<br />
t<br />
1x 2/3 A<br />
Lithium<br />
2x Mignon<br />
LR6<br />
Alkaline<br />
Master<br />
IR<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS<br />
Levels of temperature<br />
Temperature range<br />
External temperature<br />
sensor<br />
Plug-in time switches<br />
ED-on-time<br />
(setting of<br />
switching cycle)<br />
Battery handling<br />
IR-Transmitter<br />
Available languages<br />
for menu navigation
what options can we offer you to optimize<br />
your energy use and lower your costs?<br />
what are the different requirements in<br />
private and in industrial environments?<br />
These are the un<strong>de</strong>rlying questions that<br />
motivate us in our daily work to exceed<br />
the expectations of our customers.<br />
your senses. our soluTions.<br />
3
intelligent products for efficient use of<br />
time, temperature and light.<br />
soluTions To saTisfy The highesT<br />
sTandards.<br />
Dedicated to more quality of life<br />
“Your senses. Our solutions.” is the promise of performance<br />
that Grässlin keeps in all of its activities: we are<br />
<strong>de</strong>dicated to people feeling comfortable in their living<br />
and working spaces. We do this with future-oriented<br />
product ranges for time, temperature and light that also<br />
help save precious energy. It is no coinci<strong>de</strong>nce that<br />
Grässlin is esteemed as the trusted partner of industry,<br />
electricians and wholesalers in over 50 countries. This<br />
is ensured by our keen sense for process-oriented and<br />
economical solutions that <strong>de</strong>light users and ensure the<br />
highest possible <strong>de</strong>gree of customer satisfaction.<br />
Innovation backed by tradition and vision<br />
Grässlin was foun<strong>de</strong>d in 1956 and is consi<strong>de</strong>red a pioneer<br />
in time switch technology. With a number of inventions<br />
in the early years already, the company was quickly<br />
established as an internationally respected specialist in the<br />
sectors of time switch technology, temperature and light<br />
control as well as hour metering technology. In the course<br />
of globalization, Grässlin followed new pathways. Today,<br />
Grässlin is a member of Intermatic Inc., a market lea<strong>de</strong>r<br />
in time switch technology in the United States, Canada,<br />
Mexico and other countries. Through intensive cooperation<br />
in research and <strong>de</strong>velopment, Grässlin is thus able<br />
to implement international expertise in all its products.<br />
This is an advantage that our customers and partners<br />
profit greatly from.<br />
5
6<br />
feeling<br />
Grässlin keeps its promise of perfor-<br />
mance in all of its activities to<br />
ensure the highest possible <strong>de</strong>gree<br />
of customer satisfaction and to fulfill<br />
the market requirements. Grässlin´s<br />
digital weekly chronothermostat<br />
is the result of this promise: with<br />
mo<strong>de</strong>rn <strong>de</strong>sign and a wi<strong>de</strong> variety<br />
of programs available to control<br />
energy consumption by just pushing<br />
one button. A large and easy-to-<br />
read display as well as an easy<br />
programming philosophy offer a<br />
user-friendly product to all genera-<br />
tions. The <strong>de</strong>vice is available with a<br />
2- wired connection or as wireless<br />
version for application in boilers,<br />
central heating installations, circula-<br />
tion pumps, actuators or motor<br />
valves.<br />
Up to 48 different time & tempera-<br />
ture “events” per day create a com-<br />
fortable environment all day long.<br />
feeling offers various running mo<strong>de</strong>s<br />
to select from <strong>de</strong>pending on the<br />
individual situation: AUTO, Overri<strong>de</strong>,<br />
ECO-FIX, Cleaning, Countdown,<br />
Party, Holiday and OFF.<br />
Also, the product offers an auto-<br />
matic changeover of summer- and<br />
wintertime. Due to a small battery<br />
hol<strong>de</strong>r at the front of the <strong>de</strong>vice, bat-<br />
tery replacements can easily be<br />
handled without loss of programs<br />
and without dismounting the pro-<br />
duct. Providing high flexibility, user-<br />
friendliness and various intelligent<br />
energy-saving-functions, the new<br />
feeling product range is the perfect<br />
solution to match individual require-<br />
ments.<br />
talento plus top Serie<br />
The annual time switches from<br />
the talento plus TOP range offer a<br />
series of advantages that pay off<br />
in a special way for installation,<br />
handling and maintenance. Now,<br />
the battery can easily be changed<br />
from the front, so that it is no longer<br />
necessary to remove the module<br />
from the switch cabinet. In addition,<br />
talento plus TOP products can<br />
flexible communicate through the<br />
Grässlin Powerline protocol GPL<br />
with a channel extension and a LAN<br />
module. The integration of the LAN<br />
modules enables a transfer of<br />
program through the network.
<strong>Program</strong>med for success.<br />
feeling - grässlin‘s new<br />
chronoThermosTaTs.<br />
• Day/Month/Year:<br />
Displays current day/month/year<br />
• Week day:<br />
Displays the day of the week<br />
• Current time:<br />
Displays in 12 or 24 h format<br />
• Heating status:<br />
Displays heating ON or OFF<br />
• SET temperature:<br />
Displays set temperature for current period of<br />
time<br />
• Graphic histogram:<br />
Shows programmed temperature level all day<br />
long<br />
• Room temperature:<br />
Displays current room temperature<br />
• Running mo<strong>de</strong>s<br />
• Sli<strong>de</strong>r front cover<br />
• Push buttons<br />
• Battery hol<strong>de</strong>r & batteries<br />
7
8<br />
Tested quality down to the finest <strong>de</strong>tail.<br />
Precision ma<strong>de</strong> in germany.<br />
Maximum reliability in the daily use of the<br />
products. With functional <strong>de</strong>sign that leaves<br />
nothing to be <strong>de</strong>sired.<br />
Light and temperature controls from Grässlin:<br />
easy handling and self-explanatory menu<br />
navigation for the highest <strong>de</strong>gree of convenience.
Grässlin products stand for highest quality and reliable<br />
service. As a certified enterprise, Grässlin guarantees<br />
seamless quality management from the i<strong>de</strong>a to final<br />
testing of the finished product. Think global – act local is<br />
the principle un<strong>de</strong>rlying all our activities. Our worldwi<strong>de</strong><br />
specialists procure the best components, which are<br />
then transformed into products of highest precision at<br />
our site in St. Georgen. The resulting products are<br />
solutions that make a long-term and reliable contribution<br />
to efficient use of time, temperature and light both<br />
indoors and outdoors.<br />
Exemplary quality workmanship based on<br />
certified processes: the best prerequisites for<br />
gaining satisfied customers.<br />
9
10<br />
Table of contents<br />
Time switches<br />
Solutions for centrally switching different rooms, vacation programs,<br />
universal tasks and specific requirements.<br />
DIN-rail time switches talento<br />
talento plus digital – Overview p. 14<br />
talento plus Standard p. 22<br />
talento plus Medium p. 24<br />
talento plus Top p. 30<br />
talento analog – Overview p. 36<br />
Accessories p. 28, 32, 34, 42<br />
Universal time switches / time switch modules<br />
Overview p. 44<br />
Universal time switches analog tactic p. 46<br />
Time switch modules analog FM/1 p. 48<br />
Universal time switches digital tactic plus p. 50<br />
Time switch modules digital FMD p. 52<br />
EMD p. 54<br />
Phase-out and backup mo<strong>de</strong>ls p. 56<br />
Accessories p. 57<br />
room thermostats<br />
Simple handling, elegant <strong>de</strong>sign and compelling performance features<br />
for controlling time and temperature as nee<strong>de</strong>d.<br />
Radio controlled room thermostat clocks<br />
Overview p. 60<br />
feeling p. 62<br />
famoso p. 64<br />
Receiver p. 66<br />
Wired room thermostat clocks<br />
Overview p. 61<br />
feeling p. 68<br />
famoso p. 70<br />
Thermostats<br />
Overview p. 72<br />
thermio p. 74
light control<br />
Efficient solutions for internal and external use, for shop windows,<br />
street lighting, billboards, etc.<br />
Staircase lighting<br />
Overview p. 80<br />
trealux p. 82<br />
Accessories p. 88<br />
Photoelectric switches<br />
Overview p. 81<br />
turnus p. 84<br />
Accessories p. 88<br />
Plug-in and tariff time switches, hour meters<br />
Reliable product ranges for years to come,<br />
for analog or digital time control; automatic fish fee<strong>de</strong>r.<br />
Plug-in time switches<br />
Overview p. 92<br />
topica p. 94<br />
Accessories p. 94<br />
Automatic fish fee<strong>de</strong>r<br />
rondomatic p. 96<br />
Accessories p. 96<br />
Tariff time switches<br />
tasu p. 96<br />
Hour meters<br />
taxxo p. 98<br />
Accessories p. 100<br />
service and in<strong>de</strong>x<br />
A complete overview of all phase out and backup mo<strong>de</strong>ls, texts for<br />
offers and ten<strong>de</strong>rs, technical <strong>de</strong>finitions and explanations.<br />
Service<br />
Customer services p. 104<br />
In<strong>de</strong>x<br />
Overview follow-up types p. 106<br />
Product directory p. 110<br />
11<br />
Inhaltsverzeichnis
12<br />
Time swiTches<br />
din-rail time switches, universal time switches<br />
save energy with intelligent<br />
time switch technology.
Grässlin’s state-of-the-art time switch technology makes life in resi<strong>de</strong>ntial, office,<br />
commercial and industrial buildings easier, safer and helps to save energy efficiently. The<br />
innovative products convince through self-explanatory menu navigation and problem-free<br />
installation. DIN-rail and universal time switches from the talento and tactic product ranges<br />
offer diverse use options both indoors and outdoors, for central switching of different<br />
rooms, vacation programs and universal switching tasks in switching stations, in machine<br />
controls or specific solutions such as swimming pool or sprinkler system controls. The<br />
multifunctional time switch products are offered in digital and in analog versions. With their<br />
exemplary quality workmanship, Grässlin’s DIN-rail and universal time switches enable a<br />
broad spectrum of smart and energy saving applications.<br />
talento din-rail time switches<br />
talento plus digital p. 14<br />
talento plus Standard p. 22<br />
talento plus Medium p. 24<br />
talento plus Top p. 30<br />
talento analog p. 36<br />
Accessories p. 28, 32, 34, 42<br />
universal time switches / time switch modules<br />
Overview p. 44<br />
Universal time switches analog tactic p. 46<br />
Time switch modules analog FM/1 p. 48<br />
Universal time switches digital tactic plus p. 50<br />
Time switch modules digital FMD p. 52<br />
EMD p. 54<br />
Phase-out and backup mo<strong>de</strong>ls p. 56<br />
Accessories p. 57<br />
Time swiTches<br />
13<br />
Time switches
14<br />
TalenTo Plus<br />
overview digital din-rail time switches<br />
Channels 1 1 2 1 2 1<br />
Connection voltage<br />
(Ord.-No.)<br />
230 V / 50-60 Hz<br />
100-120 V / 50-60 Hz<br />
24 V AC/DC<br />
12 V AC/DC<br />
talento 371 mini plus<br />
Switching programs daily-,<br />
weekly program<br />
TAleNTo PlUS STANDARD TAleNTo PlUS meDIUm<br />
03.72.0001.1 03.73.0001.1<br />
03.73.0005.1<br />
03.73.0004.1<br />
talento 371 plus<br />
talento 372 plus<br />
03.73.0002.1<br />
03.73.0008.1<br />
03.73.0007.1<br />
03.73.0003.1<br />
daily-,<br />
weekly program<br />
talento 471 plus<br />
talento 472 plus<br />
03.75.0001.1<br />
03.75.0005.1<br />
03.75.0002.1<br />
03.75.0006.1<br />
daily-,<br />
weekly program<br />
talento 671 plus DCF<br />
03.75.0003.1<br />
03.75.0004.1<br />
daily-,<br />
weekly program<br />
Display lighting – –<br />
Memory spaces 50 50 50 50<br />
Pulse function – –<br />
Cycle function – –<br />
Date-<strong>de</strong>pen<strong>de</strong>nt<br />
switching program<br />
–<br />
Random switching – –<br />
External input<br />
Manual switching<br />
– –<br />
IR interface for<br />
PC programming<br />
– –<br />
IR interface for time<br />
synchronisation<br />
– –<br />
Antenna input<br />
Autom. summertime /<br />
wintertime changeover<br />
– – – DCF 77 + GPS<br />
Running reserve 3 years<br />
(replaceable battery)<br />
3 years 3 years 3 years<br />
Further technical<br />
information<br />
p. 22 p. 22 p. 24 p. 24
talento 791 plus<br />
talento 792 plus<br />
1 2 1 2 2 –<br />
TalenTo Plus<br />
03.74.0001.1 03.74.0002.1 03.74.0003.1 03.76.0004.1 03.76.0003.1 07.75.0003.1 07.75.0009.1<br />
ASTRO daily-,<br />
weekly prog.<br />
ASTRO<br />
TAleNTo PlUS meDIUm<br />
ASTRO daily-,<br />
weekly-,<br />
annual program<br />
daily-,<br />
weekly-,<br />
annual program*<br />
– –<br />
– 50 – 800 – –<br />
– – * –<br />
– – * –<br />
– – * –<br />
– – * –<br />
– – – –<br />
* –<br />
– – – –<br />
– – – – –<br />
– DCF 77 + GPS – DCF 77 + GPS – –<br />
3 years 3 years 3 years<br />
(replaceable battery)<br />
– –<br />
– –<br />
p. 26 p. 26 p. 30 p. 32 p. 32<br />
*) in connection with talento 892/992 plus<br />
talento 791 plus DCF<br />
talento 892 plus<br />
talento 992 plus<br />
TAleNTo PlUS ToP<br />
talento Ce plus talento lAN plus<br />
–<br />
15<br />
Time switches
16<br />
TalenTo Plus sTandard – medium<br />
easy operation – talento plus standard – medium<br />
operation ...<br />
– “Operation“ is the pivotal point of our digital time switches ma<strong>de</strong> by Grässlin.<br />
– Like a mobile phone, programming is self-explanatory:<br />
• 3 text lines for the menus = clear display of the selection options<br />
• Flexible button assignment = clear choice of input commands<br />
• Simple manual switch function = directly accessible without button combinations<br />
... with a system: IR-optical wavegui<strong>de</strong> and GPS<br />
Matched to a wi<strong>de</strong> range of needs, the talento plus product line is splitted into different<br />
levels:<br />
talento plus meDIUm<br />
The medium class communicates without complicated bus technology via a highly<br />
interference-resistant IR optical wavegui<strong>de</strong>. As a result, IR-linked units always run<br />
synchronised and all switching commands are carried out simultaneously at precisely the<br />
set time. The talento plus system receives the correct time signal anywhere in the world<br />
via GPS or DCF 77 (in Europe) and passes it on to all time switches within the system.<br />
An extra feature that, by the way, can also easily be retro-fitted in ol<strong>de</strong>r systems:<br />
One DCF 77 input is sufficient!<br />
astro: lighting specialties<br />
The talento 791/792 plus products are especially well-suited for lighting applications. Only<br />
the longitu<strong>de</strong> and the latitu<strong>de</strong> need to be entered for precice automatic<br />
<strong>de</strong>termination of the times for sunrise and sunset. With an offset time entry the respective<br />
switching times can be moved forward or back.
Variable data transfer<br />
Antenna GPS Antenna DCF external<br />
button<br />
talento VM plus<br />
talento 472 plus<br />
talento 671 plus<br />
Schematic diagram.<br />
<strong>Program</strong> transmission with talento taxxi plus<br />
talento<br />
taxxi plus<br />
TalenTo Plus sTandard – medium<br />
PC<br />
talento plus meDIUm<br />
• Simple operation with menu technology<br />
• Illuminated display<br />
• Pulse and cycle function<br />
• Date range<br />
• Random switching<br />
• External input for pre-select switching or countdown<br />
• DCF or GPS time synchronisation<br />
• IR interface for IR optical wavegui<strong>de</strong> and transfer of<br />
program<br />
• Amplifier module for 50 m cable connection for time<br />
synchronisation signal<br />
• PC-supported program creation<br />
• <strong>Program</strong> transfer with talento taxxi plus<br />
Installing IR optical wavegui<strong>de</strong><br />
• Open break-out section on si<strong>de</strong> surfaces of cover<br />
• Shorten IR optical wavegui<strong>de</strong> to <strong>de</strong>sired length<br />
• Fit on IR interface on time switch<br />
17<br />
Time switches
18<br />
TalenTo Plus ToP<br />
easy installation – talento plus Top<br />
The talento plus annual time switches are easy to install and assist<br />
the installer with many useful functions. Thus, an illuminated display<br />
ensures easy operation. A special service function shows the<br />
maintenance status of the connected installations, thus guaranteeing<br />
problem-free and speedy maintenance. The <strong>de</strong>vices are protected<br />
from un<strong>de</strong>sired manipulations by means of a PIN co<strong>de</strong>. The co<strong>de</strong> is<br />
<strong>de</strong>fined by the installer during configuration. Attached to the front of the<br />
<strong>de</strong>vice is a battery compartment, which allows easy replacement of the<br />
battery.<br />
talento<br />
taxxi plus<br />
Schematic diagram.<br />
L<br />
N<br />
IR<br />
Antenna GPS Antenna DCF<br />
230V~<br />
The system at a glance<br />
talento 892/992 plus talento CE plus talento CE plus talento CE plus talento LAN plus<br />
The versatile annual time switches talento 892 plus / talento 992<br />
plus impress with variable communication technologies. The <strong>de</strong>vices<br />
equipped with 800 memory spaces can be expan<strong>de</strong>d to inclu<strong>de</strong><br />
additional talento CE plus channel extensions, to give a mini control<br />
system of up to eight channels. talento 892 plus / talento 992 plus<br />
communicate with the channel extensions via GPL Powerline and<br />
thus do not need any additional wiring. Data are reliably transmitted<br />
The time switches are additionally equipped with an external control<br />
input that allows an external switch to be connected to the timers.<br />
With this external switch (for example a light switch) the respective<br />
application can be switched on manually and be switched off<br />
automatically either after a previously <strong>de</strong>fined time frame (countdown<br />
timer) or at the next OFF-command of the stored ON/OFF program.<br />
Compared with talento 892 plus, talento 992 plus has an additional<br />
antenna connection for a GPS or DCF77 antenna.<br />
Powerline Communication<br />
max. 50m<br />
external<br />
button<br />
LAN<br />
Internet<br />
between the annual time switch and the channel extension over a<br />
distance of 50 m.<br />
The talento LAN plus module can be used to conveniently transmit<br />
switching programs created or changed by means of the talento dialog<br />
plus software to the annual time switch via a local network or Internet<br />
from a PC. Data transfer between LAN module and annual time switch<br />
is effected by Powerline Communication.<br />
talento dialog plus
Powerline communication<br />
+ =<br />
talento dialog plus<br />
Building A Building B Building C<br />
TalenTo Plus ToP<br />
Problem-free data transmission between the annual time switch, the channel extensions and the LAN module via the mains in one single phase is<br />
ensured by the Powerline GPL communication protocol, which was specifically <strong>de</strong>veloped for the application and transmits data in the narrow band.<br />
standard<br />
50/60 Hz AC<br />
The newly <strong>de</strong>veloped talento LAN plus module establishes the<br />
connection between the annual time switch and a local network or the<br />
Internet.<br />
A program created on the PC with the talento dialog plus software can<br />
be transmitted to the LAN module without problems via a LAN network<br />
or the Internet and then via Powerline to the annual time switch. In<br />
addition to that, the LAN module also has a service function. Thus, for<br />
example, it informs the user via e-mail of possible faults like power<br />
Schematic diagram.<br />
PLC<br />
signal<br />
modulated<br />
signal<br />
lan/internet communication<br />
LAN<br />
Internet<br />
The mo<strong>de</strong>m used has the following characteristics:<br />
• Modulation: FSK (Frequency Shift Keying)<br />
• Transmission frequency: 132.5 kHz<br />
• The Powerline interface is compliant with Cenelec C band, EN50065<br />
• Maximum distance between the annual time switch and the channel<br />
extensions and LAN module: 50 m<br />
failures, low battery status or activities such as summertime/wintertime<br />
changeover and faulty or correct program transmissions to the annual<br />
time switch. A particular advantage of data transmission via the LAN<br />
network or via internet is that all program entries and service functions<br />
can be controlled conveniently from the <strong>de</strong>sk or from a control center.<br />
This avoids long travel times, allowing the working hours to be used<br />
more efficiently.<br />
Building D<br />
19<br />
Time switches
20<br />
TalenTo Plus<br />
clear menu navigation<br />
• 14 languages<br />
• Clear layout with 3-line menu text<br />
• Flexibly assigned operating buttons<br />
• Operation as easy as making a phone call<br />
MENU<br />
1 6 12 18 24<br />
1 2<br />
15:26:38<br />
Res.<br />
MENU<br />
1 6 12 18 24<br />
DATETIME<br />
PROGRAM<br />
DAYLIGHT<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
PROGRAM<br />
DAYLIGHT<br />
CONFIG<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
DAYLIGHT<br />
CONFIG<br />
RANDOM<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
DATETIME<br />
PROGRAM<br />
DAYLIGHT<br />
1 2<br />
Res.<br />
ESC OK<br />
1 6 12 18 24<br />
NUMBER<br />
CHL EXT<br />
0<br />
1 2<br />
Res.<br />
ESC OK<br />
Setting programs<br />
• Weekly or annual program<br />
• ON/OFF, pulse or cycle<br />
• Setting daylight saving time<br />
Functions may differ according to product version.<br />
1 6 12 18 24<br />
REVIEW<br />
NEW<br />
DELETE<br />
1 2<br />
Res.<br />
ESC OK<br />
1 6 12 18 24<br />
SELECT<br />
CHANNEL<br />
1<br />
1 2<br />
• Channel extension configuration<br />
• Configuration of the LAN module<br />
• Taxxi mo<strong>de</strong> for date transmission<br />
• Backlight fixed or off after 2 minutes<br />
• No unwanted manipulation thanks to entering<br />
a PIN co<strong>de</strong><br />
• Hour meter by channel<br />
• External input configuration for overri<strong>de</strong>,<br />
countdown or pulse counter.<br />
Res.<br />
ESC OK<br />
1 6 12 18 24<br />
ANNUAL<br />
WEEKLY<br />
1 2<br />
Res.<br />
ESC OK<br />
1 6 12 18 24<br />
1 2 3 4 5 6 7<br />
SELECT<br />
DAY<br />
CHL ON<br />
1 2<br />
Res.<br />
ESC OK<br />
1 6 12 18 24<br />
CONFIG<br />
RANDOM<br />
12H 24H<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
RANDOM<br />
12H 24H<br />
LANGUAGE<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
12H 24H<br />
LANGUAGE<br />
DATETIME<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
LANGUAGE<br />
DATETIME<br />
PROGRAM<br />
1 2<br />
ESC OK<br />
Res.<br />
1 6 12 18 24<br />
CYCLE<br />
ON/OFF<br />
PULSE<br />
1 2<br />
Res.<br />
ESC OK<br />
• Random move of ON or OFF<br />
switching commands during<br />
absence<br />
• Setting time display 24h or<br />
12h am/pm.<br />
• Language selection DE, EN,<br />
FR, IT, ES, PT, CS, NL, SV, NO,<br />
DA, FI, PL, HU<br />
• Setting year, month, day,<br />
hours, minutes<br />
• Factory setting CET
TalenTo Plus<br />
21<br />
Time switches
22<br />
TalenTo Plus – sTandard<br />
digital din-rail time switches<br />
Features<br />
• Daily and weekly program<br />
• 50 Memory spaces<br />
• automatic summertime/wintertime changeover<br />
• 3 years running reserve<br />
• Manual switch: FIX ON/FIX OFF<br />
• Free weekday block formation<br />
(exception talento 371 mini plus)<br />
• Non-volatile memory (EEPROM)<br />
• Date-<strong>de</strong>pen<strong>de</strong>nt program (holiday progam)<br />
(only talento 371 mini plus)<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento 371 mini plus<br />
230 V / 50-60 Hz 034078 03.72.0001.1<br />
7 x 24 h<br />
± 1 h<br />
AUTO<br />
7 x 24 h<br />
3a<br />
Lithium<br />
– Battery type CR2032, replaceable<br />
3a<br />
Lithium<br />
Fix ON/OFF<br />
Fix ON/OFF<br />
MEMORY<br />
50<br />
talento 371 plus<br />
230 V / 50-60 Hz 033910 03.73.0001.1<br />
110-120 V / 50-60 Hz 033972 03.73.0005.1<br />
24 V AC/DC 033989 03.73.0004.1<br />
talento 372 plus<br />
230 V / 50-60 Hz 033927 03.73.0002.1<br />
110-120 V / 50-60 Hz 034023 03.73.0008.1<br />
24 V AC/DC 034016 03.73.0007.1<br />
12 V AC/DC 033996 03.73.0003.1<br />
talento 371 plus, talento 372 plus<br />
Assembly accessories see page 42<br />
MEMORY<br />
50<br />
Applications<br />
• Advertising signs<br />
• Street lighting<br />
• Shop window lighting<br />
• Home & work environment<br />
• Devices, motors and pumps control<br />
Fix ... 99x24h<br />
± 1 h<br />
AUTO<br />
1x16 (8) A<br />
250 V~<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS<br />
1x16 (8) A<br />
250 V~<br />
2x16 (8) A<br />
250 V~<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS
Technical data<br />
talento 371 mini plus<br />
m~<br />
L N<br />
ch1<br />
1 2 3<br />
talento 371 plus<br />
m~<br />
L N<br />
ch1<br />
1 2 3<br />
TalenTo Plus – sTandard<br />
Dimensions H x W x D (mm) 45 x 17,5 x 60 45 x 35 x 60 45 x 35 x 60<br />
Distributor cut-out (mm) 46 x 18 46 x 36 46 x 36<br />
Weight (g) approx. 100 170 170<br />
Connection voltage<br />
dimensional drawings /<br />
circuit diagrams:<br />
230 V / 50-60 Hz 230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
24 V AC/DC<br />
Power consumption at 230 V~ (AC) 5 VA 5 VA 5 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent lamp load<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
talento 371 mini plus<br />
17,5<br />
45<br />
90<br />
60<br />
44<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
talento 371, 372 plus<br />
35<br />
45<br />
85<br />
60<br />
44<br />
230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
24 V AC/DC<br />
12 V AC/DC<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
DC switching capacity<br />
24 V–/50 V–/220 V– 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA<br />
Switch contacts 1 changeover contact 1 changeover contact 2 changeover contact<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C -10°C ... +55°C<br />
Protection class II II II<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C 3 years from factory at +20°C<br />
Shortest switching time 1 min. 1 min. 1 min.<br />
<strong>Program</strong>mable every minute every minute every minute<br />
Memory spaces 50 50 50<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF automatic / fix ON/OFF<br />
Block formation of weekdays fix presetting free assignment free assignment<br />
Holiday program/date range yes – –<br />
Backlight – – –<br />
Random generator – – –<br />
Switching state display yes yes yes<br />
Pulse switching commands – – –<br />
Cycle switching commands – – –<br />
Summer/winter time changeover automatic / freely selectable / off automatic / freely selectable / off automatic / freely selectable / off<br />
External input<br />
– Overri<strong>de</strong><br />
– Countdown<br />
–<br />
–<br />
–<br />
DCF 77 input – – –<br />
Max. terminal capacity<br />
Connection type<br />
talento 371 mini plus talento 371 plus<br />
talento 372 plus<br />
2,5 mm 2<br />
captive ± screw terminals<br />
–<br />
–<br />
–<br />
4 mm 2<br />
captive ± screw terminals<br />
Sealable yes yes yes<br />
–<br />
–<br />
–<br />
4 mm 2<br />
captive ± screw terminals<br />
talento 372 plus<br />
m~<br />
L N<br />
ch1 ch2<br />
1 2 3 5 6<br />
7<br />
23<br />
Time switches
24<br />
TalenTo Plus – medium<br />
digital din-rail time switches<br />
Features<br />
• Daily and weekly program<br />
• 50 Memory spaces<br />
• Date-<strong>de</strong>pen<strong>de</strong>nt switching programs<br />
• Automatic summer time /winter time changeover<br />
• 3 years running reserve<br />
• Manual switch: fix ON/OFF<br />
• Free weekday block formation<br />
• Non-volatile memory (EEPROM)<br />
• Pulse and cycle function<br />
• Random switching<br />
• External input<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento 471 plus<br />
230 V / 50-60 Hz 033941 03.75.0001.1<br />
110-120 V / 50-60 Hz 034054 03.75.0005.1<br />
talento 472 plus<br />
230 V / 50-60 Hz 033958 03.75.0002.1<br />
110-120 V / 50-60 Hz 034061 03.75.0006.1<br />
talento 471 plus, talento 472 plus<br />
7 x 24 h<br />
External input<br />
for countdown or<br />
overri<strong>de</strong><br />
7 x 24 h<br />
Fix ... 99x24h<br />
3a<br />
Lithium<br />
IR<br />
IR<br />
External input<br />
for countdown or<br />
overri<strong>de</strong><br />
Fix ON/OFF<br />
sec./min./h/d<br />
Fix ON/OFF<br />
sec./min./h/d<br />
MEMORY<br />
50<br />
± 1 h<br />
AUTO<br />
talento 671 plus DCF<br />
230 V / 50-60 Hz 033965 03.75.0003.1<br />
110-120 V / 50-60 Hz 034047 03.75.0004.1<br />
– IR interface inclu<strong>de</strong>d<br />
3a<br />
Lithium<br />
DCF 77<br />
GPS<br />
Amplifier module talento VM plus, see page 28<br />
Optical wavegui<strong>de</strong>, see page 28<br />
Radio antenna DCF77 and GPS, see page 34<br />
Software talento dialog plus, see page 34<br />
Assembly accessories see page 42<br />
Master<br />
MEMORY<br />
50<br />
IR<br />
• PC-supported program creation<br />
• Synchronisation time/date though optical wave gui<strong>de</strong>s<br />
Applications<br />
• Advertising signs<br />
• Street lighting<br />
• Shop window lighting<br />
• Home & work environment<br />
• Devices, motors and pumps control<br />
• Sun blinds<br />
• Shutters control<br />
• Simulation of home presence<br />
RANDOM<br />
RANDOM<br />
± 1 h<br />
AUTO<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
Fix ... 99x24h<br />
1x16 (8) A<br />
250 V~<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS<br />
1x16 (8) A<br />
250 V~<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS
Technical data<br />
Dimensions H x W x D (mm) 45 x 35 x 60 45 x 35 x 60 45 x 35 x 60<br />
Distributor cut-out (mm) 46 x 36 46 x 36 46 x 36<br />
Weight (g) approx. 170 170 220<br />
Connection voltage 230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
dimensional drawings /<br />
circuit diagrams:<br />
talento 471, 472 plus<br />
talento 671 plus DCF<br />
35<br />
talento 471 plus<br />
N<br />
L<br />
45<br />
85<br />
m~<br />
L N<br />
ch1<br />
60<br />
44<br />
1 2 3 S<br />
230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
Power consumption at 230 V~ (AC) 5 VA 5 VA 5 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent lamp load<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
talento 472 plus<br />
N<br />
L<br />
m~<br />
L N<br />
ch1 ch2<br />
1 2 3 5 6 S<br />
TalenTo Plus – medium<br />
230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
DC switching capacity<br />
24 V–/50 V–/220 V– 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA<br />
Switch contacts 1 changeover contact 1 changeover contact + 1 NO 1 changeover contact<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C -10°C ... +55°C<br />
Protection class II II II<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C 3 years from factory at +20°C<br />
Shortest switching time 1 sec. 1 sec. 1 sec.<br />
<strong>Program</strong>mable every minute every minute every minute<br />
Memory spaces 50 50 50<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF automatic / fix ON/OFF<br />
Block formation of weekdays free assignment free assignment free assignment<br />
Holiday program/date range yes yes yes<br />
Backlight yes yes yes<br />
Random generator up to 30 min. up to 30 min. up to 30 min.<br />
Switching state display yes yes yes<br />
Pulse switching commands yes: sec., min., h, days yes: sec., min., h, days yes: sec., min., h, days<br />
Cycle switching commands yes: sec., min., h, days yes: sec., min., h, days yes: sec., min., h, days<br />
Summer/winter time changeover automatic / freely selectable / off automatic / freely selectable / off automatic / freely selectable / off<br />
External input<br />
– Overri<strong>de</strong><br />
– Countdown<br />
yes<br />
yes<br />
20 min. / in steps of 30 sec.<br />
yes<br />
yes<br />
20 min. / in steps of 30 sec.<br />
DCF 77 input – – yes<br />
Max. terminal capacity<br />
Connection type<br />
talento 471 plus talento 472 plus<br />
talento 671 plus DCF<br />
4 mm 2<br />
captive ± screw terminals<br />
4 mm 2<br />
captive ± screw terminals<br />
Sealable yes yes yes<br />
yes<br />
yes<br />
20 min. / in steps of 30 sec.<br />
4 mm 2<br />
captive ± screw terminals<br />
talento 671 plus DCF<br />
N<br />
L<br />
m~<br />
L N<br />
ch1<br />
1 2 3 5 6 S<br />
25<br />
Time switches
26<br />
TalenTo Plus – medium<br />
digital din-rail time switches<br />
Features<br />
• ASTRO function (talento 792 plus also with weekly<br />
program)<br />
• Automatic summertime/wintertime changeover<br />
• 3 years running reserve<br />
• Manual switch: fix ON/OFF<br />
• Free weekday block formation<br />
• Non-volatile memory (EEPROM)<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento 791 plus<br />
230 V / 50-60 Hz 034818 03.74.0001.1<br />
talento 792 plus<br />
230 V / 50-60 Hz 034825 03.74.0002.1<br />
talento 791 plus, talento 792 plus<br />
3a<br />
Lithium<br />
ASTRO<br />
3a<br />
Lithium<br />
ASTRO<br />
Fix ON/OFF<br />
Fix ON/OFF<br />
± 1 h<br />
AUTO<br />
± 1 h<br />
AUTO<br />
± 90 min.<br />
talento 791 plus DCF<br />
230 V / 50-60 Hz 034832 03.74.0003.1<br />
DCF 77<br />
GPS<br />
Radio antenna DCF77 and GPS see page 34<br />
Assembly accessories see page 42<br />
± 90 min.<br />
Applications<br />
• Advertising signs<br />
• Street lighting<br />
• Shop window lighting<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS<br />
1x16 (8) A<br />
250 V~<br />
2x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
7 x 24 h<br />
MEMORY<br />
50
Technical data<br />
talento 791 plus<br />
m~<br />
L N<br />
ch1<br />
1 2 3<br />
talento 792 plus<br />
m~<br />
L N<br />
ch1 ch2<br />
1 2 3 5 6 7<br />
TalenTo Plus – medium<br />
Dimensions H x W x D (mm) 45 x 35 x 60 45 x 35 x 60 45 x 35 x 60<br />
Distributor cut-out (mm) 46 x 36 46 x 36 46 x 36<br />
Weight (g) approx. 170 170 220<br />
Connection voltage 230 V / 50-60 Hz 230 V / 50-60 Hz 230 V / 50-60 Hz<br />
Power consumption at 230 V~ (AC) 5 VA 5 VA 5 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent lamp load<br />
dimensional drawings /<br />
circuit diagrams:<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
talento 791 plus (DCF)<br />
talento 792 plus<br />
35<br />
45<br />
85<br />
60<br />
44<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
1000 W<br />
DC switching capacity<br />
24 V–/50 V–/220 V– 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA<br />
Switch contacts 1 changeover contact 2 changeover contact 1 changeover contact<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C -10°C ... +55°C<br />
Protection class II II II<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C 3 years from factory at +20°C<br />
Shortest switching time – 1 min. –<br />
<strong>Program</strong>mable – every minute –<br />
Memory spaces – 50 (for channel 2) –<br />
Astro program yes yes yes<br />
Astro offset ± 90 min. ± 90 min. ± 90 min.<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF automatic / fix ON/OFF<br />
Block formation of weekdays – free assignment (channel 2) –<br />
Holiday program/date range – – –<br />
Backlight yes yes yes<br />
Random generator – – –<br />
Switching state display yes yes yes<br />
Pulse switching commands – – –<br />
Cycle switching commands – – –<br />
Summer/winter time changeover automatic / freely selectable / off automatic / freely selectable / off automatic / freely selectable / off<br />
External input<br />
– Overri<strong>de</strong><br />
– Countdown<br />
–<br />
–<br />
–<br />
DCF 77 input – – yes<br />
Max. terminal capacity<br />
Connection type<br />
talento 791 plus talento 792 plus<br />
talento 791 plus DCF<br />
4 mm 2<br />
captive ± screw terminals<br />
–<br />
–<br />
–<br />
4 mm 2<br />
captive ± screw terminals<br />
Sealable yes yes yes<br />
–<br />
–<br />
–<br />
4 mm 2<br />
captive ± screw terminals<br />
talento 791 plus DCF<br />
m~<br />
L N<br />
ch1<br />
1 2 3 5 6<br />
27<br />
Time switches
28<br />
TalenTo Plus – medium<br />
digital din-rail time switches – accessories talento plus medium<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento IR plus<br />
– 034931 07.75.0013.1<br />
Replacement optical wavegui<strong>de</strong> for connecting talento 671 plus to talento<br />
471/472 plus and talento VM plus.<br />
talento Vm plus<br />
230 V / 50-60 Hz 034740 07.75.0001.1<br />
110-120 V / 50-60 Hz 034757 07.75.0002.1<br />
24 V AC/DC 034948 07.75.0014.1<br />
– The amplifier module talento VM plus is used to implement the optical IR<br />
signal on a 2-wire connection (max. 50 m).<br />
– It is possible to connect the DIN rail time switches 471 plus, 472 plus<br />
and talento 671 plus DCF with the amplifier module, whereas talento<br />
671 plus DCF must always be used as master <strong>de</strong>vice.<br />
– One <strong>de</strong>vice is required for each transmission location and one <strong>de</strong>vice for<br />
each reception location.<br />
– IR interface inclu<strong>de</strong>d.
Technical data<br />
Dimensions H x W x D (mm) 45 x 35 x 60<br />
Distributor cut-out (mm) 46 x 36<br />
Weight (g) approx. 150<br />
Connection voltage 230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
24 V AC/DC<br />
Power consumption at 230 V~ (AC) 5 VA<br />
Ambient temperature -10°C ... +55°C<br />
Protection class II<br />
Max. terminal capacity<br />
Connection type<br />
Sealable yes<br />
dimensional drawings /<br />
circuit diagrams:<br />
talento Vm plus<br />
4 mm 2<br />
captive ± screw terminals<br />
talento VM plus<br />
35<br />
45<br />
85<br />
talento VM plus<br />
m~<br />
L N<br />
A<br />
1<br />
B<br />
2<br />
60<br />
44<br />
TalenTo Plus – medium<br />
29<br />
Time switches
30<br />
TalenTo Plus – ToP<br />
digital din-rail time switches<br />
Features<br />
• Daily, weekly and annual program<br />
• 800 memory spaces<br />
• Automatic summertime/wintertime changeover<br />
• 3 years running reserve<br />
• Manual switch: fix ON/OFF / Overri<strong>de</strong><br />
• Free weekday block formation<br />
• Non-volatile memory (EEPROM)<br />
• Pulse and cycle function<br />
• Random switching<br />
• External input<br />
• PC-supported program creation<br />
• Can be expan<strong>de</strong>d to 8 channels with talento CE plus<br />
• Date-<strong>de</strong>pen<strong>de</strong>nt programming<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento 892 plus<br />
110/230 V / 50-60 Hz 034153 03.76.0004.1<br />
talento 992 plus<br />
230 V / 50-60 Hz 034146 03.76.0003.1<br />
talento 892 plus, talento 992 plus<br />
365 x 24 h<br />
0099,9<br />
3a<br />
Lithium<br />
MEMORY<br />
800<br />
– Battery Typ CR2032, replaceable<br />
Fix ON/OFF<br />
± 1 h<br />
AUTO<br />
Channel expansion talento CE plus, see page 32<br />
LAN module talento LAN plus , see page 32<br />
Radio antenna DCF77 and GPS, see page 34<br />
Software talento dialog plus, see page 34<br />
Assembly accessories see page 42<br />
External input<br />
countdown, pulse<br />
counter or overri<strong>de</strong><br />
IR<br />
• Hour counter<br />
• PIN Co<strong>de</strong><br />
• Powerline communication<br />
• LAN, internet communication<br />
Applications<br />
• Advertising signs<br />
• Street lighting<br />
• Shop window lighting<br />
• Home & work environment<br />
• Devices, motors and pumps control<br />
• Sun blinds and shutters control<br />
• Simulation of home presence<br />
LAN<br />
2x16 (10) A<br />
250 V~<br />
2x16 (10) A<br />
250 V~<br />
PLC<br />
DCF 77<br />
GPS<br />
RANDOM<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS<br />
SV, NO, DA, FI<br />
PL, HU
Technical data<br />
Dimensions H x W x D (mm) 45 x 52,5 x 60 45 x 52,5 x 60<br />
Distributor cut-out (mm) 46 x 54 46 x 54<br />
Weight (g) approx. 180 250<br />
Connection voltage 110 / 230 V 50-60 Hz 230 V / 50-60 Hz<br />
Power consumption at 230 V~ (AC) 5 VA 5 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent-/Halogen lamp load<br />
– Fluorescent lamp, compensated<br />
– Fluorescent lamp, uncompensated<br />
– Rated load AC1 / AC15<br />
16 A / 250 V AC<br />
10 A / 250 V AC<br />
2600 W / 2600 W<br />
1000 W<br />
1000 W<br />
3700 VA / 750 VA<br />
talento 892, 992 plus<br />
52,5<br />
45<br />
85<br />
talento 892 plus<br />
N<br />
L<br />
m~<br />
L N<br />
60<br />
44<br />
ch1 ch2<br />
1 2 3 5 6 7 S<br />
16 A / 250 V AC<br />
10 A / 250 V AC<br />
2600 W / 2600 W<br />
1000 W<br />
1000 W<br />
3700 VA / 750 VA<br />
DC switching capacity<br />
24 V–/50 V–/220 V– 800 mA / 300 mA / 150 mA 800 mA / 300 mA / 150 mA<br />
Min. switching load 500 mW 500 mW<br />
Switch contacts 2 changeover contact 2 changeover contact<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C<br />
Protection class II II<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C<br />
Shortest switching time 1 sec. 1 sec.<br />
<strong>Program</strong>mable every minute every minute<br />
Memory spaces 800 800<br />
Manual switch automatic / overri<strong>de</strong> / fix ON/OFF automatic / overri<strong>de</strong> / fix ON/OFF<br />
Block formation of weekdays free assignment free assignment<br />
Date range yes yes<br />
Backlight yes yes<br />
Random generator up to 30 min. up to 30 min.<br />
Switching state display yes yes<br />
Pulse switching commands yes: sec., min. yes: sec., min.<br />
Cycle switching commands yes: sec., min., h, days yes: sec., min., h, days<br />
Hour counter with service function yes yes<br />
Summer/winter time changeover automatic / freely selectable / off automatic / freely selectable / off<br />
External input<br />
– Overri<strong>de</strong><br />
– Countdown<br />
– Pulse counter<br />
yes<br />
up to 90 min. / in steps of 30 sec.<br />
yes<br />
DCF 77 input – yes<br />
Max. terminal capacity<br />
Connection type<br />
4 mm 2<br />
captive ± screw terminals<br />
Sealable yes yes<br />
dimensional drawings /<br />
circuit diagrams:<br />
talento 892 plus talento 992 plus<br />
yes<br />
up to 90 min. / in steps of 30 sec.<br />
yes<br />
4 mm 2<br />
captive ± screw terminals<br />
N<br />
L<br />
talento 992 plus<br />
m~<br />
L N<br />
ch1 ch2<br />
dcf77/gPs<br />
1 2 3 5 6 7 + –<br />
S<br />
TalenTo Plus – ToP<br />
31<br />
Time switches
32<br />
TalenTo Plus – ToP<br />
digital din-rail time switches – accessories talento plus top<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento Ce plus<br />
110/230 V / 50-60 Hz 034764 07.75.0003.1<br />
– Channel extension<br />
– Powerline GPL communication enables positioning of different divi<strong>de</strong>r<br />
talento lAN plus<br />
230 V / 50-60 Hz 034894 07.75.0009.1<br />
– Module for connecting the talento 892/992 plus to a local area network or the<br />
internet for program transfer<br />
Properties:<br />
– Communication with talento 892/992 plus via GPL (Powerline communication)<br />
– Integrated web server<br />
– LAN / Internet communication<br />
– Static and dynamic IP addressing<br />
– Ethernet Port: 10Base T<br />
– Ethernet connection: RJ-45<br />
– Supported network protocols:<br />
TCP, UDP, ARP, ICMP, T FTP, DHCP, NBNS, HTT P, SMTP and NTP<br />
2x16 (10) A<br />
250 V~
Technical data<br />
Dimensions H x W x D (mm) 45 x 35 x 60 45 x 52,5 x 60<br />
Distributor cut-out (mm) 46 x 36 46 x 54<br />
Weight (g) approx. 250 200<br />
Connection voltage 110/230 V / 50-60 Hz 230 V / 50-60 Hz<br />
Power consumption at 230 V~ (AC) 5 VA 5 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent-/Halogen lamp load<br />
– Fluorescent lamp, compensated<br />
– Fluorescent lamp, uncompensated<br />
– Rated load AC1 / AC15<br />
dimensional drawings /<br />
circuit diagrams:<br />
16 A / 250 V AC<br />
10 A / 250 V AC<br />
2600 W / 2600 W<br />
1000 W<br />
1000 W<br />
3700 VA / 750 VA<br />
DC switching capacity<br />
24 V–/50 V–/220 V– 800 mA / 300 mA / 150 mA –<br />
Min. switching load 500 mW –<br />
Switch contacts 2 changeover contact –<br />
Ambient temperature -10°C ... +55°C 0°C ... +55°C<br />
Protection class II II<br />
Accuracy – –<br />
Power reserve – –<br />
Shortest switching time 1 sec. *) –<br />
<strong>Program</strong>mable every minute *) –<br />
Memory spaces – –<br />
Manual switch automatic / overri<strong>de</strong> / fix ON/OFF *) –<br />
Block formation of weekdays free assignment *) –<br />
Date range yes *) –<br />
Random generator up to 30 min. *) –<br />
Switching state display yes –<br />
Pulse switching commands yes: sec., min. *) –<br />
Cycle switching commands yes: sec., min., h, days *) –<br />
Hour counter with service function yes *) –<br />
Summer/winter time changeover automatic / freely selectable / off *) –<br />
External input – –<br />
DCF 77 input – –<br />
Max. terminal capacity<br />
Connection type<br />
4 mm 2<br />
captive ± screw terminals<br />
Sealable yes yes<br />
*) in connection with talento 892, 992 plus<br />
talento Ce plus talento lAN plus<br />
talento CE plus<br />
35<br />
talento CE plus<br />
m~<br />
L N<br />
45<br />
85<br />
60<br />
44<br />
ch1 ch2<br />
1 2 3 5 6 7<br />
–<br />
–<br />
–<br />
–<br />
–<br />
–<br />
4 mm 2<br />
captive ± screw terminals<br />
talento LAN plus<br />
52,5<br />
talento LAN plus<br />
~<br />
L N<br />
45<br />
85<br />
RJ45<br />
60<br />
44<br />
TalenTo Plus – ToP<br />
33<br />
Time switches
34<br />
TalenTo Plus<br />
digital din-rail time switches – accessories<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
Radio antenna FA GPS<br />
– 034856 07.75.0008.1<br />
– Surface-mounted installation<br />
– Cable length on <strong>de</strong>vice: 2 metres<br />
– Maximum cable length: 300 metres<br />
– Direct free alignment with satellite<br />
– Can be used outdoors (IP 54)<br />
– With 24 V DC power supply unit<br />
Radio antenna FA DCF 77<br />
– 021184 07.01.0028.1<br />
– Optional/surface-mounted installation<br />
– Cable length on <strong>de</strong>vice: 2 metres<br />
– Maximum cable length: 300 metres<br />
– Can be used outdoors (IP 54)<br />
talento taxxi plus<br />
– 034917 07.75.0011.1<br />
– Handheld programming <strong>de</strong>vice, transfers date/time and a maximum of 4 programs<br />
– Stores programs in EEPROM; bidirectional serial port<br />
– Transmission/reception of programs<br />
– Replaceable battery<br />
– Transfer of programs from time switch to time switch via talento taxxi plus<br />
Set talento taxxi plus<br />
– 034924 07.75.0012.1<br />
consisting of:<br />
– PC software „talento dialog plus“<br />
– talento taxxi plus handheld programming <strong>de</strong>vice to program the DIN rail time switches:<br />
talento 471 plus, talento 472 plus, talento 671 plus, talento 892/992 plus,<br />
– Connection cable for connecting PC to talento taxxi plus
Technical data<br />
Dimensions H x W x D (mm) d = 28 x 190 120 x 80 x 58<br />
Weight (g) approx. 230 –<br />
Connection to time switch 10 mA DC 10 mA DC<br />
Power consumption 3 mW 3 mW<br />
Reception sensitivity < 75 µ V/m at+25°C –<br />
Ambient temperature -20°C ... +60°C -25°C ... +70°C<br />
Protection type IP 54 IP 54<br />
Cable length on <strong>de</strong>vice 2 m 2 m<br />
Installation cable length max. 300m / 2 x 1,5 mm 2 max. 300m / 2 x 1,5 mm 2<br />
Power supply – 230 V AC / 24 V DC<br />
dimensional drawings /<br />
circuit diagrams:<br />
Radio antenna FA DCF 77 Radio antenna FA GPS<br />
Radio antenna FA DCF 77<br />
cable length 2 m<br />
190<br />
ø 28<br />
Radio antenna FA GPS<br />
80<br />
58<br />
grey cable<br />
120<br />
= brown<br />
signal = white<br />
TalenTo Plus<br />
35<br />
Time switches
36<br />
TalenTo<br />
overview analog din-rail time switches<br />
talento 111 mini talento 111<br />
talento 171<br />
talento 121<br />
Channels 1 1<br />
Connection voltage<br />
(Ord.-No.)<br />
220-240 V / 50 Hz<br />
230 V AC / 110 V DC<br />
130 V AC / 60 V DC<br />
30 V AC / 12 V DC<br />
01.06.0004.1 01.28.0001.1 01.28.0002.1 01.28.0003.1<br />
Switching programs daily program daily program weekly program hour program<br />
Synchronous drive<br />
Quartz drive – –<br />
Manual switch automatic / fix ON automatic / fix ON/OFF<br />
Power reserve – –<br />
Further technical<br />
information<br />
p. 38 p. 38
1 1 2<br />
02.03.0003.1 02.28.0001.1<br />
02.28.0002.1<br />
02.28.0003.1<br />
02.28.0015.1 02.28.0004.1<br />
02.28.0005.1<br />
02.28.0006.1<br />
TalenTo<br />
talento 211 mini talento 211<br />
talento 261 talento 271 talento 212 talento 202<br />
daily program daily program daily program weekly program daily<br />
program<br />
02.28.0007.1 02.28.0008.1<br />
– – –<br />
daily,<br />
weekly<br />
program<br />
automatic / fix ON automatic / fix ON/OFF automatic / fix ON/OFF<br />
50 h 150 h 150 h<br />
p. 40 p. 40 p. 40<br />
37<br />
Time switches
38<br />
TalenTo<br />
analog din-rail time switches<br />
Features<br />
• Daily or weekly program<br />
• Synchronous<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento 111 mini<br />
220-240 V / 50 Hz 022556 01.06.0004.1<br />
24 h SYNCHRON<br />
talento 111<br />
220-240 V / 50 Hz 020668 01.28.0001.1<br />
talento 171<br />
220-240 V / 50 Hz 020675 01.28.0002.1<br />
talento 121<br />
220-240 V / 50 Hz 020682 01.28.0003.1<br />
talento 111, talento 171, talento 121<br />
SYNCHRON<br />
Assembly accessories see page 42<br />
Applications<br />
• Advertising signs<br />
• Street lighting<br />
• Shop window lighting<br />
• Home & work environment<br />
• Devices, motors and pumps control<br />
1x16 (4) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
24 h<br />
7 x 24 h<br />
1 h
Technical data<br />
Dimensions H x W x D (mm) 45 x 17,5 x 60 45 x 52,5 x 60<br />
Distributor cut-out (mm) 46 x 18 46 x 54<br />
Weight (g) approx. 100 170<br />
Connection voltage 220-240 V / 50 Hz 220-240 V / 50 Hz<br />
Power consumption at 230 V~ (AC) approx. 1 VA approx. 1 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent lamp load<br />
dimensional drawings /<br />
circuit diagrams:<br />
16 A / 250 V AC<br />
4 A / 250 V AC<br />
1000 W<br />
talento 111 mini<br />
17,5<br />
45<br />
90<br />
talento 111 mini<br />
AC<br />
m~<br />
1 2<br />
3 4<br />
60<br />
44<br />
16 A / 250 V AC<br />
4 A / 250 V AC<br />
1350 W<br />
Switching output potential-free potential-free<br />
Switch contacts 1 NO 1 changeover contact<br />
Ambient temperature -25°C ... +55°C -25°C ... +55°C<br />
Protection class II II<br />
Protection type IP 20 IP 20<br />
Accuracy synchronic to network synchronic to network<br />
Power reserve – –<br />
Charging time – –<br />
Shortest switching time<br />
– daily program<br />
– weekly program<br />
– 1h-program<br />
<strong>Program</strong>mable all<br />
– daily program<br />
– weekly program<br />
– 1h-program<br />
talento 111 mini talento 111, 171, 121<br />
30 min.<br />
–<br />
–<br />
30 min.<br />
–<br />
–<br />
30 min.<br />
180 min.<br />
1,25 min.<br />
30 min.<br />
180 min.<br />
1,25 min.<br />
Clock face – yes<br />
Manual switch automatic / fix ON automatic / fix ON/OFF<br />
Connection type captive ± screw terminals captive ± screw terminals<br />
Sealable yes yes<br />
talento 111, 121, 171<br />
52,5<br />
45<br />
85<br />
talento 111, 121, 171<br />
AC<br />
m~<br />
1 2<br />
ch1<br />
3 4 5<br />
60<br />
44<br />
TalenTo<br />
39<br />
Time switches
40<br />
TalenTo<br />
analog din-rail time switches<br />
Features<br />
• Daily and/or weekly program<br />
• Quartz<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
talento 211 mini<br />
230 V AC / 130 V DC 022563 02.03.0003.1<br />
QUARTZ<br />
QUARTZ<br />
QUARTZ<br />
ACCU<br />
50 h<br />
24 h<br />
talento 211<br />
230 V AC / 130 V DC 020750 02.28.0001.1<br />
130 V AC / 60 V DC 020743 02.28.0002.1<br />
30 V AC / 12 V DC 020736 02.28.0003.1<br />
talento 261<br />
230 V AC / 130 V DC 026325 02.28.0015.1<br />
talento 271<br />
230 V AC / 130 V DC 020729 02.28.0004.1<br />
130 V AC / 60 V DC 020712 02.28.0005.1<br />
30 V AC / 12 V DC 020705 02.28.0006.1<br />
talento 211, talento 261, talento 271<br />
ACCU<br />
150 h<br />
talento 212<br />
230 V AC / 130 V DC 020699 02.28.0007.1<br />
talento 202<br />
230 V AC / 130 V DC 020767 02.28.0008.1<br />
talento 212, talento 202<br />
Assembly accessories see page 42<br />
ACCU<br />
150 h<br />
Applications<br />
• Advertising signs<br />
• Street lighting<br />
• Shop window lighting<br />
• Home & work environment<br />
• Devices, motors and pumps controls<br />
1x16 (4) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
2x16 (4) A<br />
250 V~<br />
2x16 (4) A<br />
250 V~<br />
24 h<br />
24 h / 15 min.<br />
7 x 24 h<br />
24 h 24 h<br />
7 x 24 h<br />
24 h
Technical data<br />
Dimensions H x W x D (mm) 45 x 17,5 x 60 45 x 52,5 x 60 45 x 105 x 60 45 x 52,5 x 63<br />
Distributor cut-out (mm) 46 x 18 46 x 54 46 x 108 46 x 54<br />
Weight (g) approx. 110 170 220 160<br />
Connection voltage 230 V AC / 130 V DC 230 V AC / 130 V DC 230 V AC<br />
130 V AC/60 V DC –<br />
30 V AC/12 V DC –<br />
Power consumption at 230 V~ (AC) approx. 1 VA approx. 1 VA approx. 1 VA<br />
AC switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– Incan<strong>de</strong>scent lamp load<br />
dimensional drawings / circuit diagrams:<br />
talento 211 mini<br />
17,5<br />
45<br />
90<br />
talento 211 mini<br />
AC<br />
DC<br />
m~<br />
1 2<br />
60<br />
44<br />
ch1<br />
3 4<br />
16 A / 250 V AC<br />
4 A / 250 V AC<br />
1000 W<br />
talento 211, 261, 271 talento 202, 212<br />
52,5<br />
45<br />
85<br />
talento 211, 261, 271<br />
m~<br />
AC<br />
DC<br />
1 2<br />
ch1<br />
3 4 5<br />
60 (63)<br />
44<br />
talento 202, 212<br />
m~<br />
AC<br />
DC<br />
1 2<br />
16 A / 250 V AC<br />
4 A / 250 V AC<br />
1350 W<br />
105<br />
ch1 ch2<br />
3 4 5 6 7 8<br />
45<br />
85<br />
16 A / 250 V AC<br />
4 A / 250 V AC<br />
900 W<br />
Switching output potential-free potential-free potential-free<br />
Switch contacts 1 NO 1 CO 2 CO 1 CO<br />
Ambient temperature -20°C ... +55°C -20°C ... +55°C -20°C ... +55°C<br />
Protection class II II II<br />
Protection type IP 20 IP 20 IP 20<br />
Accuracy typ ± 2,5 sec./day at +20°C typ ± 2,5 sec./day at +20°C typ ± 2,5 sec./day at +20°C<br />
Power reserve 50 h 150 h 150 h<br />
Charging time 100 h 70 h 70 h<br />
Shortest switching time<br />
– daily program<br />
– weekly program<br />
– 1h-program<br />
<strong>Program</strong>mable all<br />
– daily program<br />
– weekly program<br />
– 1h-program<br />
talento 211 mini talento 261<br />
30 min.<br />
–<br />
–<br />
30 min.<br />
–<br />
–<br />
talento 211<br />
talento 271<br />
30 min.<br />
180 min.<br />
–<br />
30 min.<br />
180 min.<br />
–<br />
talento 202<br />
talento 212<br />
15 min.<br />
–<br />
–<br />
15 min.<br />
–<br />
–<br />
Clock face – yes –<br />
Manual switch automatic / fix ON automatic / fix ON/OFF automatic / fix ON/OFF<br />
Connection type captive ± screw terminals captive ± screw terminals captive ± screw terminals<br />
Sealable yes yes no<br />
60<br />
44<br />
TalenTo<br />
41<br />
Time switches
42<br />
TalenTo / TalenTo Plus<br />
accessories – din-rail time switches<br />
for ean-co<strong>de</strong> 4010940 ord.-no.<br />
Wall installation kit 1 module<br />
talento 111 mini 002657 18.01.0004.2<br />
talento 211 mini<br />
talento 371 mini plus<br />
Wall installation kit 2-3 modules<br />
talento 111, 121, 171 021719 03.53.0083.2<br />
talento 211, 261, 271<br />
talento 3xx plus<br />
talento 4xx plus<br />
talento 6xx plus<br />
talento 7xx plus<br />
talento 892 plus<br />
talento 992 plus<br />
talento CE plus<br />
talento LAN plus<br />
Wall installation kit 6 modules<br />
talento 202, 212 021733 03.59.0046.2<br />
Installation frame up to 6 Te<br />
talento plus 021726 03.59.0047.2<br />
lithium battery type CR2032<br />
talento 371 mini plus 032821 09.02.0012.8<br />
talento 892/992 plus
Technical data<br />
Dimensional drawings /<br />
circuit diagrams:<br />
Wall installation kit 1 module<br />
36 55<br />
120<br />
Wall installation kit 2, 3, 6 modules<br />
2/3 TE = 66<br />
6 TE =121 68<br />
Installation frame 1– 6 modules<br />
145<br />
TalenTo / TalenTo Plus<br />
43<br />
Time switches
44<br />
TacTic / fm<br />
overview analog universal time switches / time switch modules<br />
Channels 1 1 1 1<br />
Connection voltage<br />
(Ord.-No.)<br />
220-240 V / 50-60 Hz 01.80.0001.1 01.80.0002.1<br />
01.76.0088.1 01.76.0089.1<br />
230 V AC / 130 V DC<br />
230 V / 50-60 Hz<br />
110-120 V / 50-60 Hz<br />
24 V AC/DC<br />
12 V AC/DC<br />
3,4 V DC<br />
02.80.0001.1 02.80.0002.1<br />
02.76.0075.1 02.76.0076.1<br />
Central European Time (CET) – – – –<br />
Switching programs daily<br />
program<br />
tactic 111.1 tactic 171.1<br />
Universal time switch<br />
weekly<br />
program<br />
tactic 211.1 tactic 271.1<br />
Universal time switch<br />
daily<br />
program<br />
weekly<br />
program<br />
Fm/1 STuZH Fm/1 SWuZH<br />
Time switch module<br />
daily<br />
program<br />
weekly<br />
program<br />
Fm/1 QRTuZH Fm/1 QRWuZH<br />
Time switch module<br />
daily<br />
program<br />
Text programming – – – –<br />
Weekday blocks – – – –<br />
Memory spaces<br />
Manual switching (fix ON/OFF)<br />
– – – –<br />
Pre-selection switching (overri<strong>de</strong>) – – – –<br />
AM/PM switch – – – –<br />
Summer-/wintertime changeover – – – –<br />
Synchronous drive – –<br />
Quartz drive – –<br />
<strong>Program</strong>mable every<br />
Clock face<br />
15 min. 2 h 15 min. 2 h 15 min. 2 h 15 min. 2 h<br />
Running reserve – 150 h – 150 h<br />
Further technical<br />
information<br />
p. 46 p. 46 p. 48 p. 48<br />
weekly<br />
program
overview analog universal time switches / time switch modules<br />
tactic 371.1 plus<br />
tactic 372.1 plus<br />
Universal time switch<br />
tactic 571.1 plus<br />
tactic 572.1 plus<br />
Universal time switch<br />
FmD 120 FmD 220<br />
Time switch module<br />
FmD 150<br />
Time switch module<br />
emD 120 emD 220<br />
Time switch module<br />
1 2 1 2 1 2 1 1 2 2<br />
TacTic / fm<br />
emD 250<br />
Time switch module<br />
03.62.0001.1 03.62.0002.1 03.87.0001.1 03.87.0003.1<br />
03.87.0004.1<br />
03.58.0017.1 03.58.0019.1 03.60.0001.1<br />
03.87.0002.1 03.87.0005.1<br />
03.87.0006.1<br />
03.85.0003.1 03.85.0005.1 03.86.0003.1<br />
– – –<br />
daily,<br />
daily,<br />
daily,<br />
daily,<br />
daily,<br />
daily,<br />
weekly program weekly program weekly program weekly program weekly program weekly program<br />
– – –<br />
single days or week<br />
free single days or week<br />
free single days or week<br />
free<br />
day block formation<br />
day block formation<br />
day block formation<br />
pre<strong>de</strong>termined<br />
pre<strong>de</strong>termined<br />
pre<strong>de</strong>termined<br />
20 50 20 50 20 50<br />
– – – –<br />
– –<br />
manual automatic manual automatic manual automatic<br />
– – – – – –<br />
– – – – – –<br />
every minute every minute every minute every minute every minute every minute<br />
– – – – – –<br />
3 years 3 years 3 years 3 years 3 years 3 years<br />
p. 50 p. 50 p. 52 p. 52 p. 54 p. 54<br />
45<br />
Time switches
46<br />
TacTic<br />
analog universal time switches<br />
Features<br />
• Battery backup with quartz version<br />
• Daily or weekly program<br />
• 1 channel<br />
• 16 A/250 V AC switching capacity<br />
• Surface, flush and DIN-rail mounting<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
tactic 111.1<br />
220-240 V / 50 Hz 003975 01.80.0001.1<br />
tactic 171.1<br />
220-240 V / 50 Hz 003982 01.80.0002.1<br />
tactic 111.1, tactic 171.1<br />
SYNCHRON<br />
tactic 211.1<br />
230 V AC / 130 V DC 004019 02.80.0001.1<br />
tactic 271.1<br />
230 V AC / 130 V DC 004026 02.80.0002.1<br />
tactic 211.1, tactic 271.1<br />
QUARTZ<br />
Accessories see page 57<br />
ACCU<br />
150 h<br />
Applications<br />
• Machinery control<br />
• Heating systems control<br />
• Devices, motors and pumps controls<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
24 h<br />
7 x 24 h<br />
24 h<br />
7 x 24 h
Technical data<br />
Dimensions H x W x D (mm) 72 x 72 x 55 72 x 72 x 55<br />
Cut out (mm) 68 x 68 68 x 68<br />
Dimensions of front frame (mm) 72 x 72 72 x 72<br />
Fitting <strong>de</strong>pth (mm) 39,5 39,5<br />
Weight (g) approx. 155 165<br />
Nominal voltage 220-240 V AC / 50 Hz 230 V AC / 130 V DC<br />
Power consumption<br />
Current output<br />
1 VA at 230 V AC 2 VA at 230 V AC<br />
– relay<br />
changeover contact, potential-free changeover contact, potential-free<br />
Switching current AC<br />
– ohmic load (VDE, IEC)<br />
– ohmic load (UL)<br />
– inductive load cos. φ 0.6<br />
– incan<strong>de</strong>scent lamp load<br />
16 A / 250 V AC<br />
21 A / 250 V AC<br />
8 A / 250 V AC<br />
1300 W<br />
tactic 111.1, 171.1, 211.1, 271.1<br />
80<br />
tactic 111.1, 171.1, 211.1, 271.1<br />
OFF<br />
72<br />
5 4<br />
m~<br />
3 2 1<br />
55<br />
39,5<br />
16 A / 250 V AC<br />
21 A / 250 V AC<br />
8 A / 250 V AC<br />
1300 W<br />
Minimum switching current AC 100 mA / 20 V AC 100 mA / 20 V AC<br />
Minimum switching current DC 100 mA / 20 V DC 100 mA / 20 V DC<br />
Power reserve – 150 h<br />
Battery charge time – 70 h<br />
Accuracy synchronic to network typ ± 1,5 sec./day at +20°C<br />
Ambient temperature -20°C ... +55°C -20°C ... +55°C<br />
Protection class II II<br />
Shortest switching time<br />
– daily program<br />
– weekly program<br />
Shortest switching interval<br />
– daily program<br />
– weekly program<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF<br />
Clock face yes yes<br />
Sealable possible possible<br />
According to EN 60730-1<br />
EN 60730-2-7<br />
Type of connection flat DIN 6.3 mm<br />
Fitted socket (Accessories)<br />
dimensional drawings /<br />
circuit diagrams:<br />
tactic 111.1<br />
tactic 171.1<br />
tactic 211.1<br />
tactic 271.1<br />
EN 60730-1<br />
EN 60730-2-7<br />
flat DIN 6.3 mm<br />
Fitted socket (Accessories)<br />
Tappet position<br />
ON<br />
Manual switch<br />
ON<br />
Auto<br />
OFF<br />
5 4<br />
5 4<br />
5 4<br />
OFF<br />
m~<br />
3 2 1<br />
m~<br />
3 2 1 5 4<br />
m~<br />
3 2 1<br />
m~<br />
3 2 1<br />
TacTic<br />
47<br />
Time switches
48<br />
fm1<br />
analog time switch modules<br />
Features<br />
• Battery backup with quartz version<br />
• Daily or weekly program<br />
• 1 Channel<br />
• 16 A/250 V AC switching capacity<br />
• Compatible fi tting with digital time switch modules FMD<br />
• Only for fitted mounting‘<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
Fm/1 STuZH<br />
220-240 V / 50 Hz 000264 01.76.0088.1<br />
Fm/1 SWuZH<br />
220-240 V / 50 Hz 000271 01.76.0089.1<br />
Fm/1 STuZH, Fm/1 SWuZH<br />
SYNCHRON<br />
Fm/1 QRTuZH<br />
230 V AC / 130 V DC 000592 02.76.0075.1<br />
Fm/1 QRWuZH<br />
230 V AC / 130 V DC 000608 02.76.0076.1<br />
Fm/1 QRTuZH, Fm/1 QRWuZH<br />
QUARTZ<br />
Accessories see page 57<br />
ACCU<br />
150 h<br />
Applications<br />
• Appliances control<br />
• Gas boilers control<br />
• Devices, motors and pumps controls<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
24 h<br />
7 x 24 h<br />
24 h<br />
7 x 24 h
Technical data<br />
Dimensions H x W x D (mm) 60 x 60 x 32 60 x 60 x 32<br />
Cut out (mm) ø 64 ø 64<br />
Fitting <strong>de</strong>pth (mm) 21 21<br />
Weight (g) approx. 75 75<br />
Nominal voltage 220-240 V AC / 50 Hz 230 V AC / 130 V DC<br />
Power consumption<br />
Current output<br />
1 VA at 220 V AC 2 VA at 220 V AC<br />
– relay<br />
changeover contact, potential-free changeover contact, potential-free<br />
Switching current AC<br />
– ohmic load (VDE, IEC)<br />
– ohmic load (UL)<br />
– inductive load cos. φ 0.6<br />
– incan<strong>de</strong>scent lamp load<br />
16 A / 250 V AC<br />
21 A / 250 V AC<br />
8 A / 250 V AC<br />
1350 W<br />
FM/1 S, FM/1 Q<br />
FM/1 S, FM/1 Q<br />
OFF<br />
54 21<br />
60 32<br />
5 4<br />
ø 3,4<br />
m~<br />
3 2 1<br />
ø 62<br />
16 A / 250 V AC<br />
21 A / 250 V AC<br />
8 A / 250 V AC<br />
1350 W<br />
Minimum switching current AC 100 mA / 20 V AC 100 mA / 20 V AC<br />
Minimum switching current DC 100 mA / 20 V DC 100 mA / 20 V DC<br />
Power reserve – 150 h<br />
Battery charge time – 70 h<br />
Accuracy synchronic to network typ ± 1,5 sec./day at +20°C<br />
Ambient temperature -40°C ... +85°C -20°C ... +55°C<br />
Protection class II II<br />
Shortest switching time<br />
– daily program<br />
– weekly program<br />
Shortest switching interval<br />
– daily program<br />
– weekly program<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
15 min.<br />
2 h<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF<br />
Clock face yes yes<br />
According to EN 60730-1<br />
EN 60730-2-7<br />
EN 60730-1<br />
EN 60730-2-7<br />
Type of connection Fitted socket DIN 6,3 Fitted socket DIN 6,3<br />
dimensional drawings /<br />
circuit diagrams:<br />
Fm/1 S Fm/1 Q<br />
Tappet position<br />
ON<br />
Manual switch<br />
ON<br />
Auto<br />
OFF<br />
5 4<br />
5 4<br />
5 4<br />
OFF<br />
m~<br />
3 2 1<br />
m~<br />
3 2 1 5 4 3<br />
m~<br />
3 2 1<br />
m~<br />
2 1<br />
fm1<br />
49<br />
Time switches
50<br />
TacTic Plus<br />
digital universal time switches<br />
Features<br />
• Easy programming (menu-led or text programming)<br />
• Daily and weekly program<br />
• Compatible fitting with mechanical universal time switches<br />
tactic<br />
• Surface, flush and DIN-rail mounting<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
tactic 371.1 plus<br />
230 V / 50-60 Hz 038007 03.62.0001.1<br />
tactic 372.1 plus<br />
230 V / 50-60 Hz 038014 03.62.0002.1<br />
tactic 371.1 plus, tactic 372.1 plus<br />
MEMORY<br />
20<br />
MEMORY<br />
50<br />
± 1 h<br />
± 1 h<br />
AUTO<br />
3a<br />
Lithium<br />
3a<br />
Lithium<br />
7 x 24 h<br />
– Menu-led programming with flexible and fixed programs<br />
tactic 571.1 plus<br />
230 V / 50-60 Hz 038021 03.87.0001.1<br />
24 V AC / DC 038038 03.87.0002.1<br />
tactic 572.1 plus<br />
230 V / 50-60 Hz 038045 03.87.0003.1<br />
110-120 V / 50-60 Hz 038052 03.87.0004.1<br />
24 V AC/DC 038069 03.87.0005.1<br />
12 V AC/DC 038076 03.87.0006.1<br />
tactic 571.1 plus, tactic 572.1 plus<br />
– Text programming<br />
Accessories see page 57<br />
7 x 24 h<br />
Applications<br />
• Machinery control<br />
• Heating systems<br />
• Devices, motors and pumps controls<br />
Fix ON/OFF<br />
Fix ON/OFF<br />
1x16 (4) A<br />
250 V~<br />
2x16 (2,5) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
2x16 (2,5) A<br />
250 V~<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS
Technical data<br />
Dimensions H x W x D (mm) 72 x 72 x 55 72 x 72 x 55 72 x 72 x 61 72 x 72 x 61<br />
Cut out (mm) 68 x 68 68 x 68<br />
Fitting <strong>de</strong>pth (mm) 39,5 42<br />
Frame dimensions DIN 43700 (mm) 72 x 72 72 x 72<br />
Weight (g) approx. 170 190<br />
Nominal voltage 230 V AC / 50-60 Hz 230 V AC / 50-60 Hz<br />
– – – 110-120 V AC / 50-60 HZ<br />
– 24 V AC/DC – 24 V AC/DC<br />
– – – 12 V DC<br />
Power consumption<br />
Current output<br />
4,4 VA 4,4 VA<br />
– relay<br />
1 changeover contact, potential-free 2 changeover contact, potential-free<br />
Switching current AC<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos. φ 0.6<br />
– incan<strong>de</strong>scent lamp load<br />
16 A / 250 V AC<br />
4 A / 250 V AC 8 A / 250 V AC<br />
1000 W<br />
Switching current DC 10 A / 24 V DC<br />
3 A / 60 V DC<br />
1 A / 100 V DC<br />
tactic 371.1, 571.1 plus<br />
80<br />
tactic 371.1, 571.1 plus<br />
1<br />
72<br />
m~<br />
2<br />
3<br />
4<br />
5<br />
55<br />
39,5<br />
tactic 372.1, 572.1 plus<br />
80<br />
tactic 372.1, 572.1 plus<br />
m~<br />
1 2<br />
16 A / 250 V AC<br />
2,5 A / 250 V AC<br />
500 W<br />
13 A / 24 V DC<br />
0,7 A / 60 V DC<br />
0,3 A / 100 V DC<br />
Minimum switching current AC 100 mA / 20 V AC 100 mA / 20 V AC<br />
Minimum switching current DC 100 mA / 20 V DC 100 mA / 20 V DC<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C<br />
Shortest switching time 1 min. 1 min.<br />
Shortest switching interval 1 min. 1 min.<br />
Number of channels 1 2<br />
Memory spaces 20 50 20 50<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF<br />
Switching state display yes yes<br />
Summer-/wintertime changeover button ± 1 h automatic button ± 1 h automatic<br />
According to EN 60730-1<br />
EN 60730-2-7<br />
dimensional drawings /<br />
circuit diagrams:<br />
tactic 371.1 plus tactic 571.1 plus tactic 372.1 plus tactic 572.1 plus<br />
EN 60730-1<br />
EN 60730-2-7<br />
72<br />
ch1 ch2<br />
61<br />
42<br />
3 4 5 6 7 8<br />
TacTic Plus<br />
51<br />
Time switches
52<br />
fmd<br />
digital time switch modules<br />
Features<br />
• Easy programming (menu-led or text programming)<br />
• Daily and weekly program<br />
• Compatible fitting with mechanical time switch modules<br />
FM<br />
• Only for fitted mounting<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
FmD 120<br />
230 V / 50-60 Hz 037949 03.58.0017.1<br />
FmD 220<br />
230 V / 50-60 Hz 037963 03.58.0019.1<br />
FmD 120, FmD 220<br />
MEMORY<br />
20<br />
MEMORY<br />
50<br />
± 1 h<br />
± 1 h<br />
AUTO<br />
3a<br />
Lithium<br />
3a<br />
Lithium<br />
7 x 24 h<br />
– Menu-led programming with flexible and fixed programs<br />
– Further voltage types on request<br />
FmD 150<br />
230 V / 50-60 Hz 037970 03.60.0011.1<br />
– Text programming<br />
– Further voltage types on request<br />
7 x 24 h<br />
Applications<br />
• Appliances control<br />
• Gas boilers control<br />
• Devices, motors and pumps controls<br />
1x16 (4) A<br />
250 V~<br />
2x5 (1) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS
Technical data<br />
Dimensions H x W x D (mm) 60 x 60 x 32 60 x 60 x 32<br />
Cut out (mm) ø 64 ø 64<br />
Fitting <strong>de</strong>pth (mm) 21 21<br />
Weight (g) approx. 90 90<br />
Nominal voltage 230 V AC / 50-60 Hz 230 V AC / 50-60 Hz<br />
Power consumption 4,4 VA 4,4 VA<br />
Current consumption without load 0,015 mA 0,015 mA<br />
Switching current – relay 1 CO 2 NO<br />
potential-free<br />
FMD 120, 220, 150<br />
FMD 120, 150<br />
ø 3,4<br />
54 21<br />
60 32<br />
5 4<br />
m~<br />
3 2 1<br />
ø 62<br />
1 CO<br />
potential-free<br />
Switching current AC<br />
– ohmic load (VDE, IEC) 16 A / 250 V AC 5 A / 250 V AC 16 A / 250 V AC<br />
– ohmic load (UL) 16 A / 250 V AC – 16 A / 250 V AC<br />
– inductive load cos. φ 0.6 4 A / 250 V AC 1 A / 250 V AC 8 A / 250 V AC<br />
– incan<strong>de</strong>scent lamp load 1000 W – 1000 W<br />
Switching current DC<br />
10 A / 24 V DC<br />
3 A / 60 V DC<br />
1 A / 100 V DC<br />
2 A / 24 V DC<br />
0,3 A / 60 V DC<br />
0,1 A / 100 V DC<br />
10 A / 24 V DC<br />
3 A / 60 V DC<br />
1 A / 100 V DC<br />
Minimum switching current AC 100 mA / 20 V AC 100 mA / 20 V AC<br />
Minimum switching current DC 100 mA / 20 V DC 100 mA / 20 V DC<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C<br />
Shortest switching time 1 min. 1 min.<br />
Shortest switching interval 1 min. 1 min.<br />
Number of channels 1 2 1<br />
Memory spaces 20 50<br />
Overri<strong>de</strong> yes yes<br />
Switching state display yes yes<br />
Summer-/wintertime changeover button ± 1 h automatic<br />
Type of connection DIN Fitted socket 6,3 mm *) DIN Fitted socket 6,3 mm *)<br />
According to EN 60730-1<br />
EN 60730-2-7<br />
*) Further types of connection on request<br />
dimensional drawings /<br />
circuit diagrams:<br />
FmD 120 FmD 220<br />
relay<br />
FmD 150<br />
relay<br />
EN 60730-1<br />
EN 60730-2-7<br />
FMD 220<br />
5 4<br />
m~<br />
3 2 1<br />
fmd<br />
53<br />
Time switches
54<br />
emd<br />
digital time switch modules<br />
Features<br />
• Easy programming (menu-led or text programming)<br />
• Daily and weekly program<br />
• Only for fitted mounting<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
emD 120<br />
3,4-6 V DC 039424 03.85.0003.1<br />
emD 220<br />
3,4-6 V DC 040123 03.85.0005.1<br />
emD 120, emD 220<br />
MEMORY<br />
20<br />
MEMORY<br />
50<br />
± 1 h<br />
± 1 h<br />
AUTO<br />
3a<br />
Lithium<br />
3a<br />
Lithium<br />
7 x 24 h<br />
– Menu-led programming with flexible and fixed programs<br />
emD 250<br />
3,4-6 V DC 039448 03.86.0003.1<br />
– Text programming<br />
7 x 24 h<br />
Applications<br />
• Appliances control<br />
• Gas boilers control<br />
• Devices, motors and pumps controls<br />
C-MOS 0,1mA<br />
3,4 VDC<br />
C-MOS 0,1mA<br />
3,4 VDC<br />
Languages<br />
DE, EN, FR, IT,<br />
ES, PT, NL, CS
Technical data<br />
Dimensions H x W x D (mm) 51 x 64 x 15,5 51 x 64 x 15,5<br />
Cut out (mm) 47 x 60 47 x 60<br />
Fitting <strong>de</strong>pth (mm) 13 13<br />
Weight (g) approx. 22 22<br />
Nominal voltage 3,4 - 6 V DC 3,4 - 6 V DC<br />
Current consumption without load 0,03 mA at 3,4 V DC 0,03 mA at 3,4 V DC<br />
Current output CMOS CMOS<br />
Switching current DC 0,1 mA at 3,4 V DC 0,1 mA at 3,4 V DC<br />
Power reserve 3 years from factory at +20°C 3 years from factory at +20°C<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C<br />
Shortest switching time 1 min. 1 min.<br />
Shortest switching interval 1 min. 1 min.<br />
Number of channels 1 2 2<br />
Memory spaces 20 50<br />
Overri<strong>de</strong> yes yes<br />
Switching state display yes yes<br />
Summer-/wintertime changeover button ± 1 h automatic<br />
Type of connection 4-pole flat cable 4-pole flat cable<br />
According to EN 60730-1<br />
EN 60730-2-7<br />
dimensional drawings /<br />
circuit diagrams:<br />
51<br />
emD 120 emD 220 emD 250<br />
EMD 120, 220, 250<br />
EMD 120, 220, 250<br />
1 – +3,4 V (red)<br />
2 – 0 V<br />
3 – Channel 1, output<br />
4 – Channel 2, output<br />
64 13<br />
15,5<br />
1 2 3 4<br />
EN 60730-1<br />
EN 60730-2-7<br />
emd<br />
55<br />
Time switches
56<br />
Phase-ouT mo<strong>de</strong>ls / BackuP <strong>de</strong>Vices<br />
Phase-out mo<strong>de</strong>ls uni 45 – Backup <strong>de</strong>vices for digi 56-72/1, digi 16-72/1,<br />
mil /1 digi 42, mil 2008 and su (type series for assembling on existing sockets)<br />
Replacement<br />
for:<br />
Replacement<br />
for:<br />
scope of <strong>de</strong>livery / accessories<br />
Type / equipment Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
UNI 45 Te – Flush mounting<br />
daily program 230-240 V / 50 Hz 000202 01.50.0002.1<br />
UNI 45 We – Flush mounting<br />
weekly program 230-240 V / 50 Hz 003333 01.50.0076.1<br />
UNI 45 1he – Flush mounting<br />
1 h short-time program 230-240 V / 50 Hz 000226 01.50.0013.1<br />
mIl D150 – 1-channel / power reserve / without base<br />
daily / weekly program 220-240 V / 50-60 Hz 038588 03.87.0011.1<br />
50 Memory space<br />
digi 56-72/1 – 1-channel / power reserve<br />
daily / weekly program 220 V / 50-60 Hz<br />
56 Memory space 120 V / 50-60 Hz<br />
mIl/1 QRTuZH – 1-channel / Quartz with running reserve / without base<br />
daily program 230 V AC / 130 V DC 015671 02.45.0001.1<br />
30 V AC / 12 V DC 015695 02.45.0003.1<br />
mIl/1 QRWuZH – 1-channel / Quartz with running reserve / without base<br />
weekly program 230 V AC / 130 V DC 016142 02.45.0004.1<br />
mIl 2008 SFTu – 1-channel<br />
daily program 220-240 V / 50 Hz<br />
mIl 2008 SFWu – 1-channel<br />
weekly program 220-240 V / 50 Hz<br />
mIl 2008 QFRTu – 1-channel / power reserve<br />
daily program 230 V AC / 130 V DC<br />
30 V AC / 12 V DC<br />
mIl 2008 QFRWu – 1-channel / power reserve<br />
weekly program 230 V AC / 130 V DC<br />
SU/1 QRTuZH – Quartz with running reserve / without base<br />
daily program 220-240 V / 50-60 Hz 004347 02.05.0001.1<br />
Device is assembled on an already installed socket<br />
digi 16-72/1 – 1-channel / power reserve<br />
daily / weekly program 220-240 V / 50-60 Hz<br />
16 Memory space<br />
l = scope of <strong>de</strong>livery<br />
Product ean-co<strong>de</strong> 4010940 ord.-no.<br />
eZ = spare parts/accessories<br />
UNI 45<br />
Base L / EZ 003265 50.92.0013.4<br />
Frame L / EZ 003272 50.13.0002.4<br />
Attachment screw L / EZ 003296 50.22.0001.5<br />
Glass L / EZ 003302 50.13.0001.3<br />
Ratchet clamp L / EZ 002886 15.27.0011.4
universal time switches / time switch modules – accessories<br />
1+2 5<br />
1<br />
3 4<br />
5<br />
6 2<br />
5 3<br />
6<br />
2<br />
4<br />
1 4<br />
1<br />
Product ean-co<strong>de</strong> 4010940 ord.-no.<br />
l = scope of <strong>de</strong>livery<br />
eZ = spare parts/accessories<br />
for tactic 111.1, tactic 171.1, tactic 211.1, tactic 271.1<br />
1 - Glass L / EZ 037567 01.46.0082.6<br />
2 - Sealing glass – / EZ 003210 46.13.0002.4<br />
3 - Terminal cover L / EZ 002817 01.78.0004.6<br />
4 - Base L / EZ 003340 01.78.0002.2<br />
5 - Seal – / –Z 002848 01.45.0017.6<br />
6 - Flush mounting – / –Z 002831 01.79.0002.2<br />
socket<br />
(For front panel mounting<br />
if the sheet thickness is<br />
> 1.5 mm)<br />
for tactic 371.1 plus, tactic 372.1 plus, tactic 571.1 plus, tactic 572.1 plus<br />
1 - Base (1-channel) L / EZ 003340 01.78.0002.2<br />
(2-channel) L / EZ 002718 03.52.0003.2<br />
2 - Terminal cover<br />
(1-channel) L / EZ 002817 01.78.0004.6<br />
(2-channel) L / EZ 002749 01.96.0043.6<br />
3 - Frame L / EZ 002763 03.52.0006.6<br />
(2-channel)<br />
4 - Mounting plate<br />
for rail (2-channel) – / EZ 002770 01.46.0334.2<br />
5 - Glass (tactic 3xx plus,<br />
5xx plus) L / EZ 037567 01.46.0082.6<br />
6 - Sealing glass – / EZ 003210 01.78.0021.6<br />
(1-channel)<br />
for Fm/1 Q, Fm/1 S<br />
1 - Glass – / –Z 011215 01.76.0054.6<br />
2 - Flush mounting – / –Z 002831 01.79.0002.2<br />
socket<br />
TacTic / fm<br />
57<br />
Time switches
58<br />
room ThermosTaT clocks<br />
room thermostat clocks, thermostats<br />
year-round comfort with<br />
precision room thermostats.
Grässlin room thermostats offer a variety of options for sensitively controlling resi<strong>de</strong>ntial,<br />
office, commercial and industrial buildings and simultaneously ensure that valuable energy<br />
is saved. The famoso and thermio product lines are distinguished by high functionality and<br />
intelligent performance features for controlling time and temperature tailored to need. The<br />
products’ outstanding quality and reliability ensure that use is precise and safe. Whether<br />
hard-wired or wireless over a radius of up to 30 metres insi<strong>de</strong> buildings – Grässlin room<br />
thermostat clocks and thermostats can be individually aligned to the respective situation<br />
in the building and can easily be installed in all systems. Simple handling goes without<br />
saying for all Grässlin room thermostats and is ensured by exemplary menu navigation.<br />
room thermostats<br />
Wireless Room Thermostat Clocks<br />
overview p. 60<br />
feeling p. 62<br />
famoso p. 64<br />
Receiver p. 66<br />
Wired Room Thermostat Clocks<br />
overview p. 61<br />
feeling p. 68<br />
famoso p. 70<br />
Thermostats<br />
overview p. 72<br />
thermio p. 74<br />
room ThermosTaT clocks<br />
59<br />
Room thermostat<br />
clocks
60<br />
feeling, famoso<br />
overview wireless room thermostat clocks<br />
Connection voltage<br />
(Ord,-No.)<br />
Battery white<br />
anthracite<br />
silver<br />
220-240 V / 50-60 Hz<br />
feeling D 101 rf famoso 601 rf<br />
famoso 651 rf<br />
04.11.0001.1<br />
04.11.0002.1<br />
04.11.0003.1<br />
04.53.0005.1 04.53.0004.1<br />
Switching programs weekly program<br />
with up to 48 time and<br />
temperature level changes<br />
weekly program weekly program<br />
Actual roomtemperature – –<br />
Un<strong>de</strong>rfloor heating – – –<br />
Further technical<br />
information<br />
p. 62 p. 64 p. 64
overview wired room thermostat clocks<br />
feeling D 101 famoso 500 famoso 550 famoso 505 famoso 555 famoso 601<br />
04.10.0001.1<br />
04.10.0002.1<br />
04.10.0003.1<br />
weekly program<br />
with up to 48 time and<br />
temperature level changes<br />
04.34.0001.1 04.34.0002.1 04.34.0005.1 04.34.0006.1<br />
daily<br />
program<br />
weekly<br />
program<br />
daily<br />
program<br />
weekly<br />
program<br />
04.40.0008.1<br />
daily<br />
program<br />
– – –<br />
– – –<br />
p. 68 p. 70 p. 70 p. 70<br />
feeling, famoso<br />
61<br />
Room thermostat<br />
clocks
62<br />
feeling<br />
wireless room thermostat clocks<br />
Features<br />
• Digital weekly chronothermostats with mo<strong>de</strong>rn <strong>de</strong>sign and<br />
large, easy-to-read display<br />
• Available in 3 mo<strong>de</strong>rn colors: White, Anthracite, Silver<br />
• Up to 48 different time & temperature “events” per day<br />
• Various running mo<strong>de</strong>s to select from <strong>de</strong>pending on the<br />
situation: AUTO, Overri<strong>de</strong>, ECO-FIX, Cleaning, Countdown,<br />
Party, Holiday and OFF<br />
• Total OFF function with anti-freeze temperature<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no. <strong>de</strong>scription<br />
feeling d 101 rf set - Set consisting of: Transmitter and receiver<br />
2 x 1.5 V 039974 04.11.0004.1 Transmitter white<br />
230V / 50-60 Hz Receiver<br />
2 x 1.5 V 039981 04.11.0005.1 Transmitter anthracite<br />
230V / 50-60 Hz Receiver<br />
2 x 1.5 V 039998 04.11.0006.1 Transmitter silver<br />
230V / 50-60 Hz Receiver<br />
feeling D 101 rf - Transmitter<br />
2 x 1.5 V 039943 04.11.0001.1 Transmitter white<br />
2 x 1.5 V 039950 04.11.0002.1 Transmitter anthracite<br />
2 x 1.5 V 039968 04.11.0003.1 Transmitter silver<br />
feeling D 101 rf Set / feeling D 101 rf<br />
7 x 24 h<br />
wireless<br />
2x Mignon<br />
LR6 • AA<br />
Alkaline<br />
48<br />
+5°C +32°C<br />
ELECTRON.<br />
ED<br />
• Wi<strong>de</strong> temperature control range (+5ºC … +32ºC)<br />
• Problem-free installation with adjustable anti-freeze<br />
temperature (+3ºC … +7ºC)<br />
• Battery discharge level monitoring and notice when<br />
batteries have to be replaced<br />
• Integrated operating hour counter<br />
• Automatic adjustment for summer- / wintertime<br />
• 2-wired connection for heating applications<br />
• Suitable for flush or wall installation<br />
– Battery type LR6/AA<br />
– Battery powered / RF output / relay output<br />
– Reliable 868 MHz RF signal that guarantees perfect communication between transmitter and receiver<br />
– Transmission range up to 30 meters (indoor 2 walls and 1 ceiling)<br />
– Pre-commissioned<br />
– Receiver see page 66<br />
t<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~
Technical data<br />
Dimensions H x W x D (mm) 87 x 154 x 27<br />
Weight (g) approx. 200<br />
Operating voltage Battery 2 x 1,5 V AA LR6 Alkaline<br />
Battery lifetime 2 year (<strong>de</strong>p. on switching frequency)<br />
Battery back-up >10 min. (programs retained in<br />
EEPROM)<br />
Switching output <strong>de</strong>pending on receiver type see p. 66<br />
Resistive load <strong>de</strong>pending on receiver type see p. 66<br />
Connection type <strong>de</strong>pending on receiver type see p. 66<br />
Regulation cycles (selectable) 2 points, PID<br />
Sensing element 100 K (at 25ºC) NTC<br />
Ambient temperature resolution 0,1ºC<br />
Time setting resolution<br />
– program<br />
– frost protection<br />
+5ºC … +32ºC (0,5ºC steps)<br />
+5ºC (adjustable +3ºC … +7ºC)<br />
Time display 24 h or 12 h AM/PM format<br />
Time setting resolution<br />
– time of day<br />
– program<br />
1 minute<br />
30 minutes<br />
Temperature control accuracy 0,5 K (20°C 3 K/hour)<br />
Thermal gradient (heating system) 3 K/hour<br />
Room temperature display range 0ºC … +50ºC<br />
<strong>Program</strong>ming weekly program with up to 48 time<br />
and temperature level changes<br />
Pre-set programs 4 + 1 user <strong>de</strong>fined<br />
Output signal RF signal<br />
RF signal 868,3 MHz<br />
RF signal range Insi<strong>de</strong> buildings 30 m<br />
(2 walls + 1 ceiling)<br />
Coding > 16,8 Mio.<br />
Power transmission < 1mW<br />
Operating temperature range Max. 45ºC<br />
Operating humidity range 10% to 90% relative humidity,<br />
not con<strong>de</strong>nsing<br />
Storing temperature limits -20ºC ... +55ºC<br />
Protection class II<br />
Protection type IP40<br />
According to EN 60730-1, EN 60730-2-7<br />
EN 60730-2-9, EN 55014-1<br />
EN 55014-2, EN 61000-6-2<br />
ETSI EN 300 220-1<br />
ETSI EN 300 220-3<br />
ETSI EN 301 489-3<br />
dimensional drawings /<br />
circuit diagrams:<br />
feeling D 101 rf<br />
87<br />
28<br />
feeling D 101 rf<br />
154<br />
circuit diagrams see page 67<br />
feeling<br />
63<br />
Room thermostat<br />
clocks
64<br />
famoso<br />
wireless room thermostat clocks<br />
Features<br />
• Transmission ensured by high quality 868 MHz<br />
• Communication range of up to 30 meters<br />
• Flat and attractive <strong>de</strong>sign<br />
• Battery operation (Transmitter)<br />
• Time and temperature control accuracy<br />
famoso 601 rf Set - Set consisting of: Transmitter and Receiver<br />
2 x 1.5 V 037437 04.53.0005.1 Transmitter<br />
230 V / 50-60 Hz Receiver<br />
famoso 651 rf Set - Set consisting of: Transmitter and Receiver<br />
2 x 1.5 V 037451 04.53.0003.1 Transmitter<br />
230 V / 50-60 Hz Receiver<br />
famoso 601 rf - Transmitter<br />
2 x 1.5 V 037444 04.53.0002.1 Transmitter<br />
famoso 651 rf - Transmitter<br />
2 x 1.5 V 037468 04.53.0004.1 Transmitter<br />
famoso 601 rf Set, famoso 651 rf Set, famoso 601 rf , famoso 651 rf<br />
2x Mignon<br />
LR6 • AA<br />
Alkaline<br />
1 2<br />
+5°C +32°C<br />
ELECTRON.<br />
ED<br />
t<br />
applications<br />
• Central Heating<br />
• Boilers/Burners<br />
• Circulation pumps<br />
• Motorized valves<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no. <strong>de</strong>scription<br />
– Receiver see page 66<br />
wireless<br />
24 h<br />
7 x 24 h<br />
24 h<br />
7 x 24 h<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~
Technical data<br />
Dimensions H x W x D (mm) 75 x 158 x 36,4 75 x 158 x 36,4<br />
Weight (g) approx. 250 250<br />
Switching output potential-free potential-free<br />
Operating voltage 2 x LR6/AA Alkaline battery 2 x LR6/AA Alkaline battery<br />
Accuracy at 25°C ± 2,5 sec. /day ± 2,5 sec. /day<br />
Battery lifetime 1 Year (<strong>de</strong>p. on switching frequency) 1 Year (<strong>de</strong>p. on switching frequency)<br />
Control range of day temperatures +5°C ... +30°C +5°C ... +30°C<br />
Control range of night temperatures +5°C ... +30°C +5°C ... +30°C<br />
Ambient temperature -5°C ... +45°C -5°C ... +45°C<br />
Antifreeze through programming at 5°C through programming at 5°C<br />
Differential gap of temperature ± 0,25 ...0,5 K ± 0,25 ...0,5 K<br />
Controller electronic, 2 points electronic, 2 points<br />
Daily program 15 min. –<br />
Weekly program – 2 h, programmable every hour<br />
Operating mo<strong>de</strong>s Day / Night / AUTO Day / Night / AUTO<br />
Timer / control yes / – yes / –<br />
Selector switch Temperature 1,2, „automatic“ Temperature 1, 2, „automatic“<br />
Assembling mo<strong>de</strong> wall mounting wall mounting<br />
Connection type wireless wireless<br />
Control period 5....30 min. 5....30 min.<br />
Transmission frequency 868,3 MHz 868,3 MHz<br />
Transmission power<br />
famoso 601 rf, 651 rf<br />
75<br />
36,5<br />
corresp. LEPT/ERC/REC 70-03 E<br />
class 7a<br />
158<br />
36,5<br />
corresp. LEPT/ERC/REC 70-03 E<br />
class 7a<br />
Transmission range approx. 30 m, in buildings approx. 30 m, in buildings<br />
Antenna internal internal<br />
Coding >16,8 Mio. >16,8 Mio.<br />
Power transmission < 1mW < 1mW<br />
Protection class II II<br />
Protection type IP 20 IP 20<br />
According to<br />
dimensional drawings /<br />
circuit diagrams:<br />
famoso 601 rf famoso 651 rf<br />
EN 60730-1<br />
EN 60730-2-7<br />
EN 60730-2-9<br />
circuit diagrams see page 67<br />
EN 60730-1<br />
EN 60730-2-7<br />
EN 60730-2-9<br />
famoso<br />
65<br />
Room thermostat<br />
clocks
66<br />
feeling, famoso<br />
wireless room thermostat clocks - receiver<br />
Features<br />
• Transmission ensured by high quality 868 MHz<br />
• Communication range of up to 30 meters<br />
• Time and temperature control accuracy<br />
• Relay-output<br />
RecUno<br />
230 V / 50-60 Hz 031220 04.52.0001.1 Receiver<br />
For use with transmitter: feeling D 101 rf,<br />
famoso 601/651 rf<br />
Application<br />
• Central Heating<br />
• Boilers/Burners<br />
• Circulation pumps<br />
• Motorized valves<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no. <strong>de</strong>scription<br />
Rec Tip rf<br />
220 - 240 V AC 038496 04.52.0006.1 Receiver<br />
For use with transmitter: feeling D 101 rf,<br />
famoso 601/651 rf<br />
Fm/1 rf (for flush installation (Gas-Boiler) – various variants available)<br />
230 V / 50-60 Hz 040710 04.52.0014.1 Receiver<br />
For use with transmitter: feeling D 101 rf,<br />
famoso 601/651 rf<br />
1x5 (1) A<br />
250 V~<br />
1x16 (4) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~
Technical data<br />
RecUno<br />
85<br />
107<br />
35<br />
Rec Tip rf<br />
141<br />
70 75<br />
38<br />
feeling, famoso<br />
Dimensions H x W x D (mm) 85 x 107 x 35 146 x 73 x 38 60 x 60 x 32<br />
Weight (g) approx. 113 207 67<br />
Switching output 1 changeover contact (potential-free) 1 NC 1 changeover contact (potential-free)<br />
Operating voltage 230 V +/- 10% 50-60 Hz 220-240 V~ 220-240 V~<br />
Resistive load 5 (1) A / 250 V 16 A / 250 V 16 A / 250 V AC, 5 A / 250 V AC<br />
Connection type screws max. 1,5 mm 2 socket / plug flat DIN 6.3 mm<br />
Fitted socket (Accessories)<br />
Transmission frequency 868,3 MHz 868,3 MHz 868,3 MHz<br />
Transmission range<br />
in buildings 30 m (2 walls + 1 ceiling) 30 m (2 walls + 1 ceiling) 30 m (2 walls + 1 ceiling)<br />
Coding > 16,8 Mio > 16,8 Mio > 16,8 Mio<br />
Power transmission < 1mW < 1mW < 1mW<br />
Radio state display LED LED LED<br />
Operating temperature limits Max. +45°C Max. +45°C Max. +45°C<br />
Operating humidity range 10% to 90% relative humidity,<br />
not con<strong>de</strong>nsing<br />
RecUno Rec Tip rf<br />
230 V~<br />
m~<br />
10% to 90% relative humidity,<br />
not con<strong>de</strong>nsing<br />
DE<br />
other variants on request<br />
10% to 90% relative humidity,<br />
not con<strong>de</strong>nsing<br />
Storing temperature limits -20°C ... +55°C -20°C ... +55°C -20°C ... +55°C<br />
Protection class II II II<br />
Protection type IP20 IP20 IP20<br />
dimensional drawings /<br />
circuit diagrams:<br />
RecUno Rec Tip rf Fm/1 rf<br />
FM/1 rf<br />
FM/1 rf<br />
ø 3,4<br />
54 21<br />
60 32<br />
1<br />
m~<br />
2<br />
3 4 5<br />
ø 62<br />
67<br />
Room thermostat<br />
clocks
68<br />
feeling<br />
room thermostat clocks, wired connection<br />
Features<br />
• Room thermostat clocks, wired connection with weekly<br />
program<br />
• Flat and attractive <strong>de</strong>sign<br />
• Time and temperature control accuracy<br />
• Available in 3 mo<strong>de</strong>rn colors: White, Anthracite, Silver<br />
• Up to 48 different time & temperature “events” per day<br />
• Various running mo<strong>de</strong>s<br />
• Automatic adjustment for summer- / wintertime<br />
1x6 (2) A<br />
250 V~<br />
2<br />
2x Mignon<br />
LR6 • AA<br />
48<br />
7 x 24 h 3<br />
Alkaline<br />
ELECTRON.<br />
Applications<br />
• Central Heating<br />
• Boilers/Burners<br />
• Circulation pumps<br />
• Motorized valves<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no. <strong>de</strong>scription<br />
feeling D 101<br />
2 x 1.5 V 039578 04.10.0001.1 white<br />
2 x 1.5 V 039929 04.10.0002.1 anthracite<br />
2 x 1.5 V 039936 04.10.0003.1 silver<br />
– Battery powered / Relay output<br />
– Battery LR6/AA<br />
+5°C +32°C<br />
ED<br />
t
Technical data<br />
Dimensions H x W x D (mm) 87 x 154 x 27<br />
Weight (g) approx. 200<br />
Operating voltage Battery 2 x 1,5V AA LR6 alkaline<br />
Battery lifetime 2 years<br />
(<strong>de</strong>p. on switching frequency)<br />
Battery back-up 10 min.<br />
(programs retained in EPROM)<br />
Switching output 1 changeover contact (potential-free)<br />
Resistive load 6 (2) A 250 V AC<br />
Connection type max. 1,5 mm 2<br />
Regulation cycles (selectable) 2 points, PID<br />
Sensing element 100 K (at 25°C) NTC<br />
Ambient temperature resolution 0,1ºC<br />
Time setting resolution<br />
– program<br />
– frost protection<br />
+5°C … +32°C (0,5°C steps)<br />
+5°C (adjustable +3°C … +7°C)<br />
Time display 24 h or 12 h AM/PM Format<br />
Time setting resolution<br />
– time of day<br />
– program<br />
1 minute<br />
30 minutes<br />
Temperature control accuracy 0,5°C (20°C 3 K/hour)<br />
Thermal gradient (heating system) 3 K/hour<br />
Room temperature display range 0ºC … +50ºC<br />
<strong>Program</strong>ming weekly program with up to 48 time<br />
and temperature level changes<br />
Pre-set programs 4 + 1 user <strong>de</strong>fined<br />
Operating temperature range Max. 45ºC<br />
Operating humidity range 10% to 90% relative humidity,<br />
not con<strong>de</strong>nsing<br />
Storing temperature limits -20ºC to +55ºC<br />
Protection class II<br />
Protection type IP40<br />
According to EN 60730-1, EN 60730-2-7<br />
EN 60730-2-9, EN 55014-1<br />
EN 55014-2, EN 61000-6-2<br />
dimensional drawings /<br />
circuit diagrams:<br />
feeling D 101<br />
feeling D 101<br />
87<br />
28<br />
wiring diagram<br />
for boiler / heater<br />
1<br />
C<br />
2<br />
154<br />
NC<br />
NO<br />
3<br />
boiler / heater<br />
wiring diagram<br />
for motorized valves<br />
N L<br />
1<br />
C<br />
NC<br />
NO<br />
2<br />
M<br />
3<br />
valve<br />
feeling<br />
69<br />
Room thermostat<br />
clocks
70<br />
famoso<br />
room thermostat clocks, wired connection<br />
Features<br />
• Wired connection<br />
• Flat and attractive <strong>de</strong>sign<br />
• Suitable time and temperature control<br />
• Time and temperature control accuracy<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
famoso 500<br />
230 V / 50-60 Hz 020231 04.34.0001.1<br />
famoso 550<br />
230 V / 50-60 Hz 020224 04.34.0002.1<br />
famoso 500, famoso 550<br />
3<br />
4<br />
ACCU<br />
100 h<br />
1 2<br />
+5°C +32°C<br />
ELECTRON.<br />
famoso 505<br />
230 V / 50-60 Hz 027421 04.34.0005.1<br />
famoso 555<br />
230 V / 50-60 Hz 027438 04.34.0006.1<br />
famoso 505, famoso 555<br />
3<br />
4<br />
ACCU<br />
5 h<br />
1 2<br />
1 2<br />
+5°C +32°C<br />
ELECTRON.<br />
– For un<strong>de</strong>rfloor heating<br />
– External temperature sensor inclu<strong>de</strong>d, cable length 4 m<br />
famoso 601<br />
2 x 1,5 V 022709 04.40.0008.1<br />
2<br />
2x Mignon<br />
LR6 • AA<br />
Alkaline<br />
+5°C +32°C<br />
ELECTRON.<br />
ED<br />
ED<br />
ED<br />
applications<br />
• Central Heating<br />
• Boilers/Burners<br />
• Circulation pumps<br />
• Motorized valves<br />
• Electr. Un<strong>de</strong>rfloor Heating (famoso 505/555)<br />
t<br />
t<br />
t<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~<br />
1x5 (1) A<br />
250 V~<br />
24 h<br />
7 x 24 h<br />
24 h<br />
7 x 24 h<br />
24 h
Technical data<br />
Dimensions H x W x D (mm) 158 x 75 x 36,5 158 x 75 x 36,5 158 x 75 x 36,5<br />
Weight (g) approx. 250 250 250<br />
Connection 230 V / 50-60 Hz 230 V / 50-60 Hz Battery, 2 x LR6 alkaline<br />
Switching capacity<br />
– ohmic load<br />
– inductive load cos. φ 0,6<br />
– minimal<br />
5 A / 250 V~<br />
1 A / 250 V~<br />
1 mA at 24 V<br />
famoso 500, 550<br />
36,5<br />
75<br />
famoso 500/550<br />
1<br />
m~<br />
Contact 4-5 closed = Heating<br />
2<br />
158<br />
3 4 5<br />
36,5<br />
5 A / 250 V~<br />
1 A / 250 V~<br />
1 mA at 24 V<br />
famoso 505, 555<br />
36,5<br />
famoso 505/555<br />
1<br />
m~<br />
75<br />
2<br />
158<br />
Contact 4-5 closed = Heating<br />
36,5<br />
5 A / 250 V~<br />
1 A / 250 V~<br />
1 mA at 24 V<br />
Switching output potential-free potential-free potential-free<br />
Switch contacts 1 changeover contact 1 changeover contact 1 changeover contact<br />
Ambient temperature -5°C ... +45°C -5°C ... +45°C -5°C ... +45°C<br />
Accuracy ± 2,5 sec./day at +25°C ± 2,5 sec./day at +25°C ± 2,5 sec./day at +25°C<br />
Running reserve 100 h 5 h battery<br />
Battery life time<br />
Shortest switching time<br />
– – approx. 1 year<br />
– daily program<br />
– weekly program<br />
Switching state display<br />
– Timer/control<br />
– Selector switch<br />
15 min.<br />
2h<br />
yes / –<br />
Temperature 1,2, „automatic“<br />
Assembling mo<strong>de</strong> Construction with receptacle<br />
terminals on supportplate<br />
Connection type 5 screw terminals<br />
each 2,5 mm2 resp. 2 x 1,0 mm2 15 min.<br />
2h<br />
yes / –<br />
Temperature 1,2, „automatic“<br />
Construction with receptacle<br />
terminals on supportplate<br />
5 screw terminals<br />
each 2,5 mm2 resp. 2 x 1,0 mm2 15 min.<br />
2h<br />
famoso 601<br />
famoso 601<br />
3 4 5 6 7 3 4 5<br />
75<br />
36,5<br />
158<br />
Contact 3-4 closed = Heating<br />
famoso<br />
yes / yes<br />
Temperature 1,2, „automatic“<br />
Construction with receptacle<br />
terminals on supportplate<br />
3 screw terminals<br />
each je 2,5 mm2 Control range of day temperatures +5°C ... +32°C +5°C ... +32°C +5°C ... +32°C<br />
Control range of night temperatures +5°C ... +32°C +5°C ... +32°C +5°C ... +32°C<br />
Antifreeze through programming at +5°C through programming at +5°C through programming at +5°C<br />
Differential gap of temperature ± 0,25 ... 0,5 K* ± 0,25 ... 0,5 K* ± 0,25 ... 0,4 K*<br />
Controller electronic electronic digital<br />
Protection class II II II<br />
Protection type IP 20 IP 20 IP 20<br />
*) higher <strong>de</strong>viations are possible <strong>de</strong>pending on the heating system and the heated room<br />
dimensional drawings /<br />
circuit diagrams:<br />
famoso 500, 550 famoso 505, 555 famoso 601<br />
36,5<br />
71<br />
Room thermostat<br />
clocks
72<br />
Thermio<br />
overview thermostats<br />
thermio e thermio 102 thermio 103<br />
thermio 402 thermio 403<br />
thermio 513<br />
Controller electronic Bi-metal Bi-metal Bi-metal<br />
Connection voltage<br />
(Ord.-No.)<br />
24 V / 50-60 Hz<br />
04.46.0014.1<br />
220-240 V / 50-60 Hz<br />
Battery<br />
04.46.0004.1 04.46.0006.1 04.46.0003.1 04.46.0005.1 04.46.0001.1<br />
Connection for time switch – – –<br />
Actual room temperature – – –<br />
Application heating heating heating heating<br />
Further technical<br />
information<br />
p. 74 p. 74 p. 74 p. 74
thermio 603 thermio 703<br />
thermio 713 thermio touch<br />
electronic electronic electronic electronic<br />
04.46.0016.1<br />
04.46.0017.1 04.46.0018.1<br />
– – –<br />
04.46.0019.1<br />
heating / cooling heating / cooling heating / cooling / fan coil cooling<br />
p. 76 p. 76 p. 76 p. 76<br />
Thermio<br />
73<br />
Room thermostat<br />
clocks
74<br />
Thermio<br />
Thermostats<br />
Features<br />
• Temperature control accuracy<br />
• Flat and attractive <strong>de</strong>sign<br />
• Possibility to connect a time switch<br />
(night-time reduction)<br />
• Surface-mounting<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
thermio e<br />
24 V / 50-60 Hz 033231 04.46.0014.1<br />
– Electronic control with digital temperature indicator (actual and <strong>de</strong>sired temp.),<br />
with power steeling<br />
– No battery required<br />
thermio 513<br />
230 V / 50-60 Hz 019167 04.46.0001.1<br />
– Bi-metal controller / Rotary knob for temperature adjustment / Manual switch<br />
for night-time reduction<br />
– Connection for time switch (night-time reduction)<br />
– Thermic feedback<br />
thermio 402<br />
230 V / 50-60 Hz 019495 04.46.0003.1<br />
thermio 403<br />
230 V / 50-60 Hz 019471 04.46.0005.1<br />
– Bi-metal controller / Rotary knob for temperature adjustment / Manual switch for heating ON/OFF<br />
– Thermic feedback<br />
thermio 102<br />
230 V / 50-60 Hz 019488 04.46.0004.1<br />
thermio 103<br />
230 V / 50-60 Hz 019464 04.46.0006.1<br />
– Bi-metal controller / Rotary knob for temperature adjustment<br />
– Connection for time switch (night-time reduction)<br />
– Thermic feedback<br />
Frame<br />
– 035044 04.46.0038.6<br />
– Fitted for all thermostats thermio<br />
– 80,5 x 80,5 mm (5 mm thick)<br />
Applications<br />
• Central heating<br />
• Boiler<br />
• Combi-boiler<br />
2<br />
3<br />
2<br />
3<br />
2<br />
3<br />
4
Technical data<br />
Dimensions H x W x D (mm) 75 x 71 x 27 75 x 71 x 27 75 x 71 x 27<br />
Weight (g) approx. 60 70 60 90<br />
Connection 2-wire 3-wire and 4-wire 2-wire and 3-wire 2-wire and 3-wire<br />
Power consumption 100 mW approx. 200 mW approx. 200 mW approx. 200 mW<br />
Switching capacity<br />
– ohmic load<br />
– inductive load cos φ 0,6<br />
– minimal<br />
dimensional drawings /<br />
circuit diagrams:<br />
–<br />
–<br />
20 mA / 24 V-<br />
thermio E, 513<br />
thermio 402, 403, 102, 103<br />
75<br />
thermio E<br />
thermio 513<br />
71 27<br />
1 2<br />
24 V AC<br />
1 2 4 4 3<br />
L N<br />
10 A / 250 V~<br />
4 A / 250 V~<br />
0,1 A / 230 V-<br />
Contact 1-2 closed = Heating<br />
Contact 3 lowering <strong>de</strong>vice via timer handling<br />
0,5 A, 5 A / 250 V~<br />
0,5 A, 4 A / 250 V~<br />
0,5 A, 1 A / 24 V-<br />
thermio 102<br />
1-2 : electrical<br />
1 ... 5 A<br />
1-4 : gas<br />
0,5 ... 1 A<br />
thermio 103<br />
1 2 4<br />
1 2 3 4 4<br />
L<br />
N<br />
10 A / 250 V~<br />
4 A / 250 V~<br />
0,1 A / 230 V-<br />
Contact 1-2 closed = Heating<br />
Contact 3 lowering <strong>de</strong>vice via timer handling<br />
0,5 A, 5 A / 250 V~<br />
0,5 A, 4 A / 250 V~<br />
0,5 A, 1 A / 24 V-<br />
thermio 402<br />
3-2 : electrical<br />
1 ... 5 A<br />
3-4 : gas<br />
0,5 ... 1 A<br />
thermio 403<br />
1 2 3 4<br />
L N<br />
Contact 3-2 closed = Heating<br />
Thermio<br />
10 A / 250 V~<br />
4 A / 250 V~<br />
0,1 A / 230 V-<br />
Switching output opens with raising temperature opens with raising temperature opens with raising temperature<br />
Switch contacts – Ag Ni Ag Ni Ag Ni<br />
Ambient temperature T 30 T 30 T 30<br />
Switching state display<br />
– control<br />
– selector switch<br />
thermio e thermio 513 thermio 102 thermio103 thermio 402 thermio 403<br />
flame icon<br />
–<br />
LED green<br />
night lowering<br />
<strong>de</strong>vice ON/OFF<br />
–<br />
–<br />
–<br />
heating ON/OFF<br />
Assembling mo<strong>de</strong> wall mounting wall mounting wall mounting<br />
Connection type screw terminal with wire protection screw terminal with wire protection screw terminal with wire protection<br />
Control range of day temperatures +5°C ... +30°C +5°C ... +30°C +5°C ... +30°C<br />
Night lowering <strong>de</strong>vice – approx. 4 K – approx. 4 K –<br />
Antifreeze – adjustable by<br />
turning knop<br />
catch<br />
adjustable by turning knop catch adjustable by turning knop catch<br />
Differential gap of temperature approx. 0,5 K approx. 0,5 K approx. 0,5 K<br />
Refeeding – thermic thermic thermic<br />
Stocking temperature -20°C ... +70°C -20°C ... +70°C -20°C ... +70°C<br />
Protection class II after accordant installation II after accordant installation II after accordant installation<br />
Protection type IP20 IP20 IP20<br />
Fault clearance of sparks according to EN 55014 according to EN 55014 according to EN 55014<br />
3 2 4<br />
75<br />
Room thermostat<br />
clocks
76<br />
Thermio<br />
Thermostats<br />
Features<br />
• Precise temperature control<br />
• Low profile, attractive <strong>de</strong>sign<br />
• Surface mounting<br />
• Combination heating / cooling<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no. icon<br />
thermio 603<br />
2 x 1,5 V 041328 04.46.0016.1<br />
– Electronic control with digital temperature indicator (actual temp.)<br />
thermio 703<br />
230 V AC / 50 Hz 041335 04.46.0017.1<br />
– Electronic control with digital temperature indicator (actual and <strong>de</strong>sired temp.)<br />
thermio 713<br />
230 V AC / 50 Hz 041342 04.46.0018.1<br />
– Electronic control with digital temperature indicator (actual and <strong>de</strong>sired temp.)<br />
– Control of fan coils<br />
thermio touch<br />
2 x 1,5 V 041359 04.46.0019.1<br />
– Electronic control with digital temperature indicator (actual and <strong>de</strong>sired temp.)<br />
– Touch screen<br />
– External input<br />
Applications<br />
• Central heating<br />
• Cooling <strong>de</strong>vices (thermio 603, 703, 713)<br />
• Boiler<br />
• Combi-boiler<br />
• Fan Coil (thermio 713)
Technical data<br />
Dimensions H x W x D (mm) 82 x 121 x 18 82 x 111 x 26 82 x 111 x 26<br />
Weight (g) approx. 108 114 128 168<br />
Connection 2 x 1,5 V LR03<br />
/ AAA<br />
dimensional drawings /<br />
circuit diagrams:<br />
thermio 603, 703<br />
81,9<br />
18<br />
thermio 603<br />
thermio 703<br />
COM<br />
NO<br />
NC<br />
Max. 6(2)A 250V AC<br />
NC<br />
COM<br />
NO<br />
120,9<br />
Max. 6(2)A 250V AC N L<br />
N<br />
L<br />
230V AC 50 Hz<br />
220-240 V /<br />
50-60 Hz<br />
N<br />
N<br />
L<br />
L<br />
220-240 V / 50-60 Hz 2 x 1,5 V LR03 / AAA<br />
Protection class || || ||<br />
Switching capacity<br />
– ohmic load (VDE, IEC)<br />
– inductive load cos φ 0,6<br />
thermio 603 thermio 703<br />
thermio 713 thermio touch<br />
max. 6 A / 250 V AC / 50 Hz<br />
max. 2 A / 250 V AC / 50 Hz<br />
max. 6 A / 250 V AC / 50 Hz<br />
max. 2 A / 250 V AC / 50 Hz<br />
thermio 713<br />
82,4<br />
26<br />
thermio 713<br />
N NC<br />
L NO<br />
111,1<br />
F1: Min. Speed<br />
F2: Med. Speed<br />
F3: Max. Speed<br />
F1 F2 F3<br />
L N<br />
HEATING/<br />
COOLING<br />
FAN<br />
230V AC 50 Hz<br />
N<br />
Max. 6(2)A 250V AC<br />
N<br />
max. 6 A / 250 V AC / 50 Hz<br />
max. 2 A / 250 V AC / 50 Hz<br />
Switching output potential-free potential-free potential-free<br />
Function mo<strong>de</strong> heating / cooling heating / cooling heating<br />
Speed fan coil – 3 speeds –<br />
Automatic antifreeze protection +5°C +5°C +5°C<br />
Differential 0.4 / 0.6°C 0.4 / 0.6°C 0.4 / 0.6°C<br />
Controlled temperature +5°C ... + 30°C +5°C ... + 35°C +5°C ... + 35°C +5°C ... + 35°C<br />
Temperature meas. range +0°C ... + 40°C +0°C ... + 40°C +0°C ... + 40°C<br />
Display temperature update every 10 sec. every 10 sec. every 10 sec.<br />
Ambient temperature -5°C ... + 45°C -5°C ... + 45°C -5°C ... + 45°C<br />
Accuracy ± 1°C at +20°C ± 1°C at +20°C ± 1°C at +20°C<br />
Resolution 0,5°C 0,5°C 0,5°C<br />
Protection type IP 30 IP30 IP 30<br />
thermio touch<br />
81,9<br />
27<br />
thermio touch<br />
NC<br />
COM<br />
NO<br />
111<br />
Thermio<br />
S1<br />
S2<br />
Max. 6(2)A 250V AC N L ext.<br />
input<br />
77<br />
Room thermostat<br />
clocks
78<br />
lighT conTrol<br />
staircase lighting, photoelectric switches<br />
selective use of lighting<br />
with individual light controls.
Grässlin light controls offer the highest possible <strong>de</strong>gree of functionality, switch separately<br />
for the <strong>de</strong>sired situation in resi<strong>de</strong>ntial, office, commercial and industrial buildings and<br />
outdoors and at the same time ensure noticeably improved energy efficiency. With the<br />
trealux product range, Grässlin presents you with well-engineered solutions for light<br />
switching in staircases or entryways – also well suited for mo<strong>de</strong>rn illuminants such as<br />
energy-saving lamps and various ballasts. The photoelectric switches in Grässlin’s turnus<br />
range operate with a light sensor to precisely control illumination according to light<br />
intensity and the time of day. These product solutions are perfectly suited for shop windows,<br />
to illuminate billboards, for street lighting, etc.<br />
staircase lighting<br />
Overview p. 80<br />
trealux p. 82<br />
Accessories p. 88<br />
Photoelectric switches<br />
Overview p. 81<br />
turnus p. 84<br />
Accessories p. 88<br />
lighT conTrol<br />
79<br />
Light control
80<br />
Trealux<br />
overview staircase lighting time switches<br />
trealux 210 trealux 510<br />
Connection voltage<br />
(Ord.-No.)<br />
230 V / 50-60 Hz 18.13.0009.1 18.13.0016.1<br />
Pre-warning<br />
Autom. recognition of<br />
3- or 4-line connection<br />
–<br />
Adjustment range 0,5 - 20 min 0,5 - 20 min<br />
Service long-term function 1h –<br />
Further technical<br />
information<br />
p. 82 p. 82
overview photoelectric switches<br />
Turnus<br />
turnus 200 turnus 501 A turnus 501 e turnus 502 A turnus 502.1<br />
turnus 771 plus<br />
turnus 772 plus<br />
Channels 1 1 2 2 1 2<br />
Connection voltage<br />
(Ord.-No.)<br />
220-240 V / 50-60 Hz 18.17.0001.1 18.18.0001.1 18.18.0006.1 18.18.0002.1 18.18.0003.1 18.22.0001.1 18.22.0002.1<br />
Max. adjustable Lux-value 2000 500 500 500<br />
Brightness sensor for ... integrated surfacemounting flushmounting surfacemounting – surfacemounting<br />
Switching program – – – weekly program<br />
Memory spaces – – – 50<br />
Autom. summertime /<br />
wintertime changeover<br />
– – –<br />
Running reserve – – – 3 years<br />
Further technical<br />
information<br />
p. 84 p. 84 p. 84 p. 86<br />
81<br />
Light control
82<br />
Trealux<br />
staircase lighting time switches<br />
Features<br />
• Electronic<br />
• Automatic recognition of 3-line or 4-line connection<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
trealux 210<br />
230 V / 50 Hz 024789 18.13.0009.1<br />
3<br />
4<br />
AUTO<br />
– Adjustment range: 0.5 – 20 minutes<br />
– Immediately adjustable<br />
– Connection from below<br />
trealux 510<br />
220-240 V / 50-60 Hz 039127 18.13.0016.1<br />
3<br />
4<br />
AUTO<br />
3x<br />
3600 W<br />
1x16 (10) A<br />
250 V~<br />
1x16 (10) A<br />
250 V~<br />
– Safety staircase lighting time switch in acc. to DIN 18015 with impulse pre-warning<br />
– Adjustment range: 0.5 – 20 minutes<br />
– If any key is pressed for more than 2 seconds, the light remains on for 1 hour<br />
Assembly accessories see page 88<br />
lighting or ventilation for<br />
• Stairs<br />
• Basements<br />
• Halls<br />
• Toilets
Technical data<br />
Dimensions H x W x D (mm) 45 x 17,5 x 62 45 x 17,5 x 62<br />
Distributor cut-out (mm) 46 x 18 46 x 18<br />
Connection 220-240 V / 50 Hz 220-240 V / 50-60 Hz<br />
Switching capacity AC<br />
– Ohmic load (VDE, IEC) cos. φ 1<br />
– Inductive load cos. φ 0,6<br />
– Incan<strong>de</strong>scent lamp load<br />
– Halogen lamp load<br />
– Halogen (low voltage)<br />
– Fluorescent lamp in DUO circuit<br />
– Fluorescent lamp, parallel compensated<br />
– Fluorescent lamp, series-compensated<br />
– Power consumption<br />
stand by mo<strong>de</strong><br />
– EVG<br />
– KVG<br />
– CFL (EVG)<br />
dimensional drawings /<br />
circuit diagrams:<br />
trealux 210 trealux 510<br />
16 A / 230 V AC<br />
10 A / 230 V AC<br />
2300 W<br />
–<br />
–<br />
20 x 2 x 58 W<br />
20 x 58 W<br />
40 x 58 W<br />
0,5 W<br />
5 x 20 W<br />
1500 W<br />
9 x 7 W; 6x 11W; 5 x 15 W; 5 x 20 W<br />
trealux 210, 510<br />
17,5<br />
45<br />
85<br />
62<br />
44<br />
16 A / 230 V AC<br />
10 A / 230 V AC<br />
3600 W<br />
3600 W<br />
1600 VA<br />
1000 VA<br />
1000 VA<br />
1000 VA<br />
0,5 W<br />
1000 VA<br />
1000 VA<br />
37 x 7 W; 27 x 11 W; 24 x 15 W;<br />
22 x 23 W<br />
Switch contacts 1 NO 1 NO<br />
Ambient temperature -10°C ... +55°C -10°C ... +55°C<br />
Protection class II II<br />
Protection type IP 20 IP 20<br />
Adjustment range 0,5 min. ... 20 min. 0,5 min. ... 20 min.<br />
Pre-warning – ja<br />
Pilot lights max. 50 x1 mA max. 50 x1 mA (3-line connection)<br />
max. 150 x1 mA (4-line connection)<br />
On-time 100% ED 100% ED<br />
Manual switch yes yes<br />
Re-triggerable once once<br />
Connection type captive ± screw terminals captive ± screw terminals<br />
Switching type automatic recognition of 3-line or<br />
4-line connection<br />
Time extension no no<br />
automatic recognition of 3-line or<br />
4-line connection<br />
trealux 210, 510<br />
3-wire-connection<br />
trealux 210, 510<br />
4-wire-connection<br />
max. 50 mA (trealux 210)<br />
max. 50 mA (trealux 510)<br />
max. 50 mA (trealux 210)<br />
max. 150 mA (trealux 510)<br />
Turnus<br />
83<br />
Light control
84<br />
Turnus<br />
Photoelectric switches<br />
Applications<br />
• Shop lighting<br />
• Car parking lighting<br />
• Shutters control<br />
• Advertising signs<br />
• Street lighting<br />
• Sun blinds<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
turnus 200<br />
220-240 V / 50-60 Hz 018986 18.17.0001.1<br />
LUX<br />
2...2000<br />
LUX<br />
2...500<br />
LUX<br />
2...500<br />
Switching<br />
ON/OFF <strong>de</strong>lay<br />
20 ... 120 sec.<br />
– With integrated brightness sensor<br />
– Surface-mounting/Outdoor-mounting<br />
Switching<br />
ON/OFF <strong>de</strong>lay<br />
100 sec. fixed<br />
Switching<br />
ON/OFF <strong>de</strong>lay<br />
0 ... 100 sec.<br />
IP 54<br />
turnus 501 A<br />
230 V / 50-60 Hz 023249 18.18.0001.1<br />
– With brightness sensor surface-mounting (1) incl. in the scope of <strong>de</strong>livery<br />
turnus 501 e<br />
230 V / 50-60 Hz 024031 18.18.0006.1<br />
– With brightness sensor, flush-mounting (2) incl. in the scope of <strong>de</strong>livery<br />
turnus 501 A, turnus 501 e<br />
turnus 502 A<br />
230 V / 50-60 Hz 023256 18.18.0002.1<br />
– With brightness sensor surface-mounting incl. in the scope of <strong>de</strong>livery<br />
turnus 502.1<br />
230 V / 50-60 Hz 023973 18.18.0003.1<br />
– Additional unit without brightness sensor<br />
turnus 502 A, turnus 502.1<br />
– Light control system<br />
– Adjustable ON/OFF switching <strong>de</strong>lay 0 – 100 sec.<br />
– Up to 10 units (20 channels) of the types turnus 502, 771 and 772 can be<br />
exten<strong>de</strong>d to form a light control system with only 1 brightness sensor<br />
Assembly accessories see page 88<br />
1x10 (2) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
1x16 (8) A<br />
250 V~<br />
2x10 (8) A<br />
250 V~<br />
2x10 (8) A<br />
250 V~
Technical data<br />
Dimensions H x W x D (mm) 111 x 83 x 43 45 x 17,5 x 60 45 x 52,5 x 60<br />
Distributor cut-out (mm) – 46 x 18 46 x 54<br />
Weight (g) approx. 175 75 285<br />
Connection 220-240 V / 50-60 Hz 230 V / 50-60 Hz 230 V / 50-60 Hz<br />
Power consumption at 230 V~ (AC) approx. 6 VA approx. 5 VA approx. 2,5 VA<br />
Switching output not potential-free (230 V) potential-free potential-free<br />
Switch contacts 1 NO 1 NO 2 changeover contacts<br />
AC switching capacity<br />
– Ohmic load (VDE, IEC)<br />
– Inductive load cos. φ 0,6<br />
– Incan<strong>de</strong>scent lamp load<br />
dimensional drawings /<br />
circuit diagrams:<br />
10 A / 250 V AC<br />
2 A / 250 V AC<br />
1200 W<br />
111<br />
turnus 200<br />
turnus 200<br />
m~<br />
µ<br />
83<br />
43<br />
220-240 V~<br />
50-60 Hz<br />
10 (2) A / 250 V~<br />
N L L<br />
16 A / 250 V AC<br />
8 A / 250 V AC<br />
2000 W<br />
turnus 501<br />
17,5<br />
45<br />
85<br />
turnus 501<br />
m~<br />
L N<br />
60<br />
44<br />
1 2 3 4<br />
Sensor<br />
10 A / 250 V AC<br />
8 A / 250 V AC<br />
2000 W<br />
turnus 502<br />
52,5<br />
turnus 502<br />
m~<br />
1 2<br />
AC<br />
45<br />
85<br />
ch1 ch2<br />
Turnus<br />
DC switching capacity<br />
24 V–/60 V–/220 V– – approx. 800 mA / 300 mA / 150 mA approx. 800 mA / 300 mA / 150 mA<br />
Functionality electronic electronic electronic<br />
Connection type captive ± screw terminals captive ± screw terminals captive ± screw terminals<br />
Sealable – – ja<br />
Ambient temperature:<br />
– Control unit<br />
– Brightness sensor<br />
Protection type:<br />
– Control unit<br />
– Brightness sensor<br />
Brightness sensor:<br />
– Length connecting lead<br />
– Terminal capacity<br />
turnus 200 turnus 501 turnus 502<br />
-35°C ... +60°C<br />
–<br />
IP 54<br />
–<br />
–<br />
–<br />
–<br />
-20°C ... +55°C<br />
-30°C ... +70°C<br />
IP 20<br />
IP 65<br />
–<br />
max. 100 m<br />
min. 0,75 mm2 -20°C ... +55°C<br />
-30°C ... +70°C<br />
IP 20<br />
IP 65<br />
SELV<br />
max. 100 m<br />
min. 0,75 mm2 Photoelectric switches:<br />
Adjustment range 2 lx – 2000 lx 2 lx – 500 lx 2 lx – 500 lx<br />
Hysteresis approx. factor 1.3 of engaging value approx. factor 1.3 of engaging value approx. factor 1.3 of engaging value<br />
Switching <strong>de</strong>lay 20 ... 120 sec. approx. 100 sec. ON / 100 sec. OFF adjustable:<br />
0-100 sec. ON / 0-100 sec. OFF<br />
Switching state display un<strong>de</strong>layed un<strong>de</strong>layed un<strong>de</strong>layed<br />
60<br />
44<br />
3 4 5 6 7 8 9 10 11<br />
Sensor<br />
85<br />
Light control
86<br />
Turnus<br />
Photoelectric switches<br />
dimensional drawings /<br />
circuit diagrams:<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
turnus 771 plus<br />
230 V / 50-60 Hz 040420 18.22.0001.1<br />
turnus 772 plus<br />
230 V / 50-60 Hz 040437 18.22.0002.1<br />
turnus 771 plus, turnus 772 plus<br />
ø 20,4<br />
08:30<br />
Sensor LF<br />
LUX<br />
2...500<br />
Assembly accessories see page 88<br />
60 25,2<br />
Switching<br />
ON/OFF <strong>de</strong>lay<br />
0 ... 100 sec.<br />
ø 32<br />
Sensor LF<br />
flush-mounting<br />
2 x 0,5 mm 2 x 450 mm<br />
PG11 (ø 18,6)<br />
± 1 h<br />
AUTO<br />
3a<br />
Lithium<br />
ø 27,4<br />
7 x 24 h<br />
– Brightness sensor for surface-mounting inclu<strong>de</strong>d in the scope of <strong>de</strong>livery<br />
– Adjustable ON/OFF switching <strong>de</strong>lay 0 – 100 sec.<br />
– Up to 10 units (20 channels) of the types turnus 502, 771 plus and 772 plus<br />
can be exten<strong>de</strong>d to form a light control system with only 1 brightness sensor<br />
– With weekly time switch<br />
Sensor lF<br />
2-500 Lux 002671 07.02.0001.1<br />
500-10.000 Lux 027643 07.02.0004.1<br />
Sensor lF flush mounting<br />
2-500 Lux 016630 07.02.0003.1<br />
Cap lF<br />
500-10.000 Lux 029166 07.02.0003.2<br />
24<br />
1x16 (10) A<br />
250 V~<br />
2x16 (10) A<br />
250 V~<br />
MEMORY<br />
50<br />
MEMORY<br />
50
Technical data<br />
Dimensions H x W x D (mm) 45 x 52,5 x 60<br />
Distributor cut-out (mm) 46 x 54<br />
Weight (g) approx. 250 285<br />
Connection 230 V / 50-60 Hz<br />
Power consumption at 230 V~ (AC) 5 VA<br />
Switching output potential-free<br />
Switch contacts 1 CO 2 CO<br />
AC Switching capacity<br />
– Ohmic load (VDE, IEC) cos. φ 1<br />
– Inductive load cos. φ 0,6<br />
– Incan<strong>de</strong>scent lamp load<br />
– Halogen lamp load<br />
– Fluorescent lamp, parallel compensated<br />
– Fluorescent lamp, series-compensated<br />
– Max. switching capacity AC1 / AC15<br />
dimensional drawings /<br />
circuit diagrams:<br />
turnus 771 plus, 772 plus turnus 771 plus<br />
turnus 772 plus<br />
52,5<br />
16 A / 250 V AC<br />
10 A / 250 V AC<br />
2600 W<br />
2600 W<br />
1000 W<br />
1000 W<br />
3700 W / 750 W<br />
DC Switching capacity<br />
24 V–/60 V–/220 V– approx. 800 mA / 300 mA / 150 mA<br />
Functionality electronic<br />
Max. Terminal capacity<br />
Connection type<br />
4 mm 2<br />
captive ± screw terminals<br />
Sealable ja<br />
Ambient temperature:<br />
– Control unit<br />
– Brightness sensor<br />
Protection type:<br />
– Control unit<br />
– Brightness sensor<br />
Brightness sensor:<br />
– Length connecting lead<br />
– Terminal capacity<br />
turnus 771 plus turnus 772 plus<br />
-10°C ... +55°C<br />
-30°C ... +70°C<br />
IP 20<br />
IP 65<br />
SELV<br />
max. 100 m<br />
min. 2 x 0,75 mm2 Photoelectric switches:<br />
Adjustment range 2 lx – 500 lx<br />
Hysteresis approx. factor 1.3 of engaging value<br />
Switching <strong>de</strong>lay adjustable:<br />
0-100 sec. ON / 0-100 sec. OFF<br />
Switching state display un<strong>de</strong>layed<br />
Time switch:<br />
Memory spaces 50<br />
Shortest switching time 1 min.<br />
<strong>Program</strong>mable every every minute<br />
Block formation of weekdays free assignment<br />
Switching state display yes<br />
Summer/wintertime changeover automatic<br />
Manual switch automatic / fix ON/OFF<br />
Accuracy typ ± 1 sec./day at +20°C<br />
Running reserve 3 years from factory<br />
45<br />
85<br />
60<br />
44<br />
m~<br />
2 LUX 500<br />
0 sec 100<br />
1 2<br />
AC<br />
1 6 12 18 24<br />
C1<br />
1 2<br />
13:48:51<br />
Res.<br />
MENU<br />
ch1<br />
2 LUX 500<br />
0 sec 100<br />
1 2<br />
3 4 5 9 10 11<br />
Sensor<br />
1 6 12 18 24<br />
C1<br />
e. g. turnus 772 plus<br />
13:48:51<br />
Res.<br />
MENU<br />
2 LUX 500<br />
0 sec 100<br />
1 6 12 18 24<br />
turnus 772 plus turnus 771 plus turnus 502 ........<br />
C1<br />
1 2<br />
13:48:51<br />
Res.<br />
MENU<br />
m~<br />
1 2<br />
AC<br />
ch1 ch2<br />
Turnus<br />
Pilot unit could be: • turnus 502<br />
• turnus 771 plus<br />
• turnus 772 plus<br />
10 units at maximum are operated as a system with a brightness sensor.<br />
Each of the units – with brightness sensor – can also be applied<br />
individually.<br />
3 4 5 6 7 8 9 10 11<br />
Sensor<br />
87<br />
Light control
88<br />
Trealux, Turnus<br />
accessories – din-rail time switches<br />
for ean-co<strong>de</strong> 4010940 ord.-no.<br />
Wall installation kit 1 Te<br />
trealux 210, 510 002657 18.01.0004.2<br />
turnus 501<br />
Wall installation kit 2-3 modules<br />
turnus 502 021719 03.53.0083.2<br />
turnus 771 plus,<br />
turnus 772 plus<br />
Installation frame up to 6 Te<br />
trealux 021726 03.59.0047.2<br />
turnus
Technical data<br />
dimensional drawings /<br />
circuit diagrams:<br />
Wall installation kit 1 TE<br />
36 55<br />
120<br />
Wall installation kit 2, 3, 6 modules<br />
2/3 TE = 66<br />
6 TE =121 68<br />
Installation frame up to 6 TE<br />
145<br />
Trealux, Turnus<br />
89<br />
Light control
90<br />
Plug-in Time swiTches, auTomaTic fish fee<strong>de</strong>rs ...<br />
Plug-in time switches, hour meters, automatic fish fee<strong>de</strong>rs<br />
efficiently link time to activity.
Plug-in Time swiTches, auTomaTic fish fee<strong>de</strong>rs ...<br />
As a pioneer for hour meters, Grässlin <strong>de</strong>cisively placed its stamp on this product field.<br />
The time-tested Grässlin hour meters from the taxxo line are maintenance-free, robust and<br />
reliable for years to come.<br />
We offer a fully <strong>de</strong>veloped range of plug-in time switches to control electrical <strong>de</strong>vices<br />
indoors and outdoors at any <strong>de</strong>sired time. The products from the topica line are available in<br />
different international plug-in systems and a number of voltages – both analog and digital.<br />
Grässlin’s high performance product range also inclu<strong>de</strong>s specialized solutions. For example,<br />
the automatic fish fee<strong>de</strong>r rondomatic 400, which ensures automated feeding in aquariums<br />
for up to four weeks.<br />
The hour meters from Grässlin guarantee safe and highly reliable tariff changeovers.<br />
The tasu product line offers you perfect solutions for analog or digital use.<br />
Plug-in time switches<br />
Overview Plug-in time switch p. 92<br />
topica p. 94<br />
Accessories p. 94<br />
automatic fish fee<strong>de</strong>rs<br />
rondomatic p. 96<br />
Accessories p. 96<br />
Tariff time switch<br />
tasu p. 96<br />
hour meters<br />
taxxo p. 98<br />
Accessories p. 100<br />
91<br />
Plug-in time switches<br />
and hour meters
92<br />
ToPica<br />
overview plug-in time switches<br />
Or<strong>de</strong>r-No. 16.25.0008.1 16.26.0008.1 16.40.0001.1 16.27.0001.1 16.15.0001.1<br />
Switching programs daily program daily<br />
program<br />
weekly<br />
program<br />
daily program daily-, weekly program<br />
Display – clock face clock face digital<br />
Memory spaces – – – 20<br />
<strong>Program</strong>mable every 15 min. 15 min. 2h 15 min. 1 min.<br />
Runnig reserve – – – 3 years<br />
Manual switch<br />
topica 200 S topica 400 S topica 450 S<br />
topica 410 S<br />
topica 600<br />
Random switching – – –<br />
Fixed weekday blocks – – –<br />
Further technical<br />
information<br />
p. 94 p. 94 p. 94 p. 94
ToPica<br />
93<br />
Plug-in time switches<br />
and hour meters
94<br />
ToPica<br />
Plug-in time switches<br />
Applications<br />
• Appliances control<br />
• Direct heating systems control<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
topica 200 S<br />
220-240 V / 50 Hz 002428 16.25.0008.1<br />
220 - 240 V<br />
50 Hz<br />
220 - 240 V<br />
50 Hz<br />
220 - 240 V<br />
50 Hz<br />
SYNCHRON<br />
topica 400 S, Clock face<br />
220-240 V / 50 Hz 002435 16.26.0008.1<br />
topica 450 S, Clock face<br />
220-240 V / 50 Hz 003906 16.40.0001.1<br />
topica 400 S, topica 450 S<br />
3a<br />
Lithium<br />
Fix ON/OFF<br />
SYNCHRON<br />
topica 410 S<br />
220-240 V / 50 Hz 016241 16.27.0001.1<br />
SYNCHRON<br />
MEMORY<br />
20<br />
7 x 24 h<br />
IP 54<br />
topica 600<br />
230 V / 50-60 Hz 039387 16.15.0001.1<br />
220 - 240 V<br />
50-60 Hz<br />
Accessory for: topica 200 S<br />
topica 400 S<br />
topica 450 S<br />
RANDOM<br />
Glass<br />
– 011215 01.76.0054.6<br />
• Lighting control<br />
• Simulation of home presence<br />
24 h<br />
24 h<br />
7 x 24 h<br />
24 h
Technical data<br />
Connection 220-240 V / 50 Hz 220-240 V / 50 Hz 230 V / 50-60 Hz<br />
Switching capacity<br />
– Ohmic load<br />
– Inductive load<br />
dimensional drawings /<br />
circuit diagrams:<br />
16 A / 250 V~ µ<br />
8 A / 250 V~ µ<br />
topica 200 S, 400 S, 450 S, 600<br />
146<br />
73<br />
75<br />
38<br />
16 A / 250 V~ µ<br />
8 A / 250 V~ µ<br />
topica 410 S<br />
155<br />
74<br />
81<br />
44<br />
16 A / 250 V~ µ<br />
4 A / 250 V~ µ<br />
Power consumption approx. 5 VA approx. 5 VA approx. 5 VA<br />
Ambient temperature<br />
– Continuous operating<br />
– Short time rating<br />
topica 200 S topica 400 S, 410 S, 450 S<br />
topica 600<br />
-10°C ... +55°C<br />
-10°C ... +55°C<br />
-10°C ... +55°C<br />
-10°C ... +55°C<br />
-10°C ... +55°C<br />
-10°C ... +55°C<br />
Running reserve – – 3 years from factory at 20°C<br />
Memory spaces – – 20<br />
Shortest switching time 15 min. 15 min. (topica 400 S, 410 S)<br />
2 h (topica 450 S)<br />
1 min.<br />
<strong>Program</strong>mable every 15 min. every 15 min. (topica 400 S, 410 S)<br />
every 2 h (topica 450 S)<br />
every minute<br />
Display – clock face LCD<br />
Manual switch automatic / fix ON/OFF automatic / fix ON/OFF automatic / fix ON/OFF<br />
Switching state display – – yes<br />
Special functions<br />
– –<br />
fixed weekday block formation<br />
or single days<br />
Random generator – – retards the switching command<br />
from 1 – 45 minutes<br />
Protection type – IP54 (410 S) –<br />
ToPica<br />
95<br />
Plug-in time switches<br />
and hour meters
96<br />
rondomaTic / Tasu<br />
automatic fish fee<strong>de</strong>r<br />
1<br />
Tariff time switches<br />
2<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
rondomatic 400 (automatic fish fee<strong>de</strong>r)<br />
230 V / 50-60 Hz 003364 16.58.0001.1<br />
220 - 240 V<br />
50-60 Hz<br />
24 h<br />
7 x 24 h<br />
28 x 24 h<br />
Accessories for rondomatic<br />
1 - Food container 017316 85.21.0002.4 L / E Z<br />
2 - Glass 017323 85.13.0001.3 L / E Z<br />
Plug-in ri<strong>de</strong>rs 024079 85.15.0006.4 L / E Z<br />
Attachment bracket 024086 16.58.0016.6 L / E Z<br />
Assembly kit 024093 16.58.0004.2 – / –Z<br />
(L = Scope of <strong>de</strong>livery, EZ = Spare parts / Accessories)<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
tasu 511 (mIl 02 T/1 QRTUZ)<br />
230 V AC / 130 V DC 013974 02.08.0001.1<br />
ACCU<br />
150 h<br />
3a<br />
Lithium<br />
QUARTZ<br />
– Cover and glass separately sealable with leads<br />
assembly:<br />
– Three-point assembly on counter panel<br />
– Clamping cover in accordance with DIN 43857, part 5<br />
tasu 672 plus (mIl 02T D250)<br />
220-240 V / 50-60 Hz 038557 03.87.0010.1<br />
Fix ON/OFF<br />
– Cover and glass separately sealable with leads<br />
MEMORY<br />
50<br />
assembly:<br />
– Three-point assembly on counter panel<br />
– Clamping cover in accordance with DIN 43857, part 5<br />
± 1 h<br />
AUTO<br />
1x10 (8) A<br />
250 V~<br />
2x10 (2,5) A<br />
250 V~
Technical data<br />
Connection 230 V / 50 Hz<br />
Operating voltage 24 V / 50 Hz<br />
Power consumption approx. 5 VA<br />
Minimal feeding interval 2 h<br />
Maximum feeding period<br />
(for daily feeding)<br />
27 days<br />
Food container<br />
Filling volume:<br />
28<br />
– per food container<br />
– total filling vol. approx.<br />
dimensional drawings /<br />
circuit diagrams:<br />
dimensional drawings /<br />
circuit diagrams:<br />
5,5<br />
rondomatic 400<br />
3,5 ccm<br />
100 ccm<br />
Repetition of feeding every 24 h<br />
rondomatic 400<br />
tasu 511<br />
85<br />
tasu 511<br />
ø166<br />
Dimensions (mm) 175 x 105 x 71 175 x 105 x 71<br />
Connection 230 V AC / 130 V DC 230 V / 50-60 Hz<br />
Power consumption approx. 2 V A approx. 4,4 V A<br />
Switching capacity 10 A / 250 V~ µ 10 A / 250 V~ µ<br />
Switching output potential-free potential-free<br />
Switch contact 1 NO 2 changeover contacts<br />
Ambient temperature -20°C ... +55°C -10°C ... +55°C<br />
Protection class II II<br />
Protection type IP 51 IP 51<br />
Accuracy typ ± 1 sec./day at +20°C typ ± 1 sec./day at +20°C<br />
Running reserve 150 h 3 years from factory at +20°C<br />
Charging time 70 h –<br />
<strong>Program</strong>mable every every 15 min. every minute<br />
Memory spaces – 50<br />
105 71<br />
125<br />
147<br />
m~<br />
1 2<br />
147<br />
3 4<br />
14,5<br />
ø 92<br />
tasu 511 tasu 672 plus<br />
44<br />
5,5<br />
tasu 672 plus<br />
105 71<br />
85<br />
tasu 672 plus<br />
m~<br />
1 2<br />
125<br />
147<br />
147<br />
ch1 ch2<br />
3 4 5 6 7 8<br />
rondomaTic / Tasu<br />
97<br />
Plug-in time switches<br />
and hour meters
98<br />
Taxxo<br />
hour meters<br />
– DIN-rail mounting<br />
– Surface-mounting<br />
* These variants are being produced only upon receipt of special or<strong>de</strong>rs.<br />
Features<br />
• Flush, surface or DIN-rail mounting<br />
• Durable, maintenance-free technology<br />
• Robust and reliable<br />
• Various dimensions, round and square<br />
• Latching screws or low profile plugs<br />
Voltage ean-co<strong>de</strong> 4010940 ord.-no.<br />
taxxo 403 (UWZ 35 V)<br />
220-240 V / 50 Hz 001773 05.21.0001.1<br />
110-120 V / 50 Hz 001780 05.21.0002.1<br />
36-48 V / 50 Hz 001797 * 05.21.0003.1 *<br />
18-26 V / 50 Hz 001803 * 05.21.0004.1 *<br />
110-127 V / 60 Hz 001810 * 05.21.0009.1 *<br />
taxxo 100 (UWZ 48 A)<br />
220-240 V/50 Hz 001339 05.15.1001.1<br />
330-380 V/50 Hz 001506 05.15.1089.1<br />
110-120 V/50 Hz 001407 05.15.1019.1<br />
36-48 V/50 Hz 001452 05.15.1049.1<br />
18-26 V/50 Hz 001377 05.15.1010.1<br />
110-127 V/60 Hz 001438 * 05.15.1026.1 *<br />
taxxo 112 (UWZ 48 KeD)<br />
220-240 V/50 Hz 002268 05.15.1038.1<br />
110-120 V/50 Hz 002282 05.15.1118.1<br />
18-26 V/50 Hz 002275 05.15.1016.1<br />
110-127 V/60 Hz 002299 * 05.15.1031.1 *<br />
– Srew terminals / Flush-mounting<br />
taxxo 612 (FWZ 36 K)<br />
220-240 V/50 Hz 001599 05.20.0006.1<br />
330-380 V/50 Hz 001742 05.20.0033.1<br />
18-26 V/50 Hz 001667 05.20.0016.1<br />
– Srew terminals (VBG4) / Flush-mounting<br />
taxxo 712 (FWZ 55 K)<br />
220-240 V/50 Hz 001582 05.20.0004.1<br />
110-120 V/50 Hz 001728 05.20.0029.1<br />
36-48 V/50 Hz 001711 05.20.0028.1<br />
18-26 V/50 Hz 001681 05.20.0018.1<br />
110-127 V/60 Hz 001629 * 05.20.0008.1 *<br />
– Srew terminals (VBG4) / Flush-mounting<br />
Applications<br />
• Machinery working time control<br />
• Pumps working time control
Technical data<br />
dimensional drawings /<br />
circuit diagrams:<br />
dimensional drawings /<br />
circuit diagrams:<br />
taxxo 403 taxxo 100 taxxo 112<br />
Dimensions H x W x D (mm) 82 x 35 x 68 69 x 48 x 43 55 x 48 x 40<br />
Switchboard panel (mm) – – 45 x 45<br />
Distributor cut-out (mm) 46 x 36 – –<br />
Mounting <strong>de</strong>pth (mm) 68 43 33<br />
Weight (g) approx. 90 70 60<br />
Connection see or<strong>de</strong>ring data see or<strong>de</strong>ring data see or<strong>de</strong>ring data<br />
Power consumption approx. 1 VA approx. 1 VA approx. 1 VA<br />
Ambient temperature -20°C ... +55°C -20°C ... +55°C -20°C ... +55°C<br />
Protection class II II II<br />
Protection type front IP 20 IP 20 IP 20<br />
Accuracy synchronic to network synchronic to network synchronic to network<br />
Metering capacitance 99999,99 h 99999,99 h 99999,99 h<br />
Run display yes yes yes<br />
Assembling mo<strong>de</strong> distributing bus bar assembling with clamp cover integration<br />
Connection type captive ± screw terminals<br />
1 x 2,5 resp. 2 x 1,5 mm2 receptacle with screw terminals screw terminals<br />
taxxo 403<br />
35<br />
45<br />
82<br />
68<br />
38<br />
taxxo 100<br />
69<br />
23,5<br />
taxxo 612 taxxo 712<br />
Dimensions H x W x D (mm) 24 x 36 x 57 30 x 55 x 71<br />
Switchboard panel (mm) 22 x 33 25 x 50<br />
Distributor cut-out (mm) – –<br />
Mounting <strong>de</strong>pth (mm) 68 66<br />
Weight (g) approx. 34 50<br />
Connection see or<strong>de</strong>ring data see or<strong>de</strong>ring data<br />
Power consumption approx. 1 VA approx. 1 VA<br />
Ambient temperature -20°C ... +55°C -20°C ... +55°C<br />
Protection class II II<br />
Protection type front IP 20 (IP 54 with sealing s. accessories) IP 20 (IP 54 with sealing s. accessories)<br />
Accuracy synchronic to network synchronic to network<br />
Metering capacitance 99999,99 h 99999,99 h<br />
Run display yes yes<br />
Assembling mo<strong>de</strong> integration integration<br />
Connection type screw terminals screw terminals<br />
taxxo 612<br />
54 3<br />
36 24<br />
24<br />
71<br />
taxxo 712<br />
14 52 5<br />
43<br />
48<br />
55 30<br />
50 25<br />
taxxo 112<br />
40<br />
55<br />
50<br />
33 45<br />
Taxxo<br />
48<br />
99<br />
Plug-in time switches<br />
and hour meters
100<br />
Taxxo<br />
hour meters / accessories<br />
2<br />
2 3<br />
1<br />
1<br />
2<br />
1<br />
L = Scope of <strong>de</strong>livery<br />
for<br />
EZ = Spare parts/Accessories<br />
ean-co<strong>de</strong> 4010940 ord.-no.<br />
for: taxxo 100<br />
1 - Base L/EZ 002862 15.92.0021.4<br />
2 - Surface mounting L/EZ 002879 50.12.0001.4<br />
housing<br />
for: taxxo 112<br />
1 - Ratchet clamp L/EZ 002886 15.27.0011.4<br />
2 - Cover 55 x 55 –/EZ 008802 05.15.0065.6<br />
Cover 72 x 72 –/EZ 008819 16.26.0006.4<br />
with sealing IP 54<br />
vertical assembly<br />
(glass vertical)<br />
–/EZ 011253 11.24.0008.8<br />
for: taxxo 612<br />
1 - Spring clip L/EZ 002961 05.20.0026.6<br />
2 - Sealing –/EZ 002978 11.24.0007.8<br />
for: taxxo 712<br />
2 - Sealing –/EZ 002992 14.24.0001.5<br />
3 - Ratchet clamp L/EZ 002985 14.27.0002.4
Taxxo<br />
101<br />
Plug-in time switches<br />
and hour meters
102<br />
serVice and in<strong>de</strong>x<br />
replacement units, product overviews<br />
competitively equipped for sucess.
Grässlin offers you differentiated service and information modules to help you expand and<br />
solidify your success in the tough competition. With the alphabetical and numerical indices<br />
you have easy access to the most important product specifications. In addition, phase-out<br />
and follow-up mo<strong>de</strong>ls are listed in the In<strong>de</strong>x to help you find the right product at a glance.<br />
With Grässlin’s Service and Information Modules you are well equipped for diverse daily<br />
<strong>de</strong>mands.<br />
service<br />
Customer services p. 104<br />
in<strong>de</strong>x<br />
Overview follow-up types p. 106<br />
Product overview p. 110<br />
serVice and in<strong>de</strong>x<br />
103<br />
Service /In<strong>de</strong>x
104<br />
serVice<br />
good service is not only part of<br />
our philosophy, but part of our daily<br />
interaction with people.
Expertise and service for customers and partners<br />
Grässlin has launched an entirely new internet presentation<br />
with a number of new service modules for the entire business<br />
spectrum, paying special attention to user-friendly navigation.<br />
Extensive product information, operating instructions and<br />
the latest product catalogues are waiting for you in our<br />
Download Center. Information and contact data for our<br />
national and international distributors are also available on<br />
our website. Our industrial partner portal offers you access to<br />
the latest i<strong>de</strong>as, innovations and product-specific <strong>de</strong>tails.<br />
Naturally, we will inform you about tra<strong>de</strong>shows and events<br />
so that you have a head-start for implementing your goals<br />
with Grässlin.<br />
Competent contacts<br />
serVice<br />
Long-standing, trustful relationships are the basis for optimal<br />
alignment to national and international markets. Therefore,<br />
in sales to the tra<strong>de</strong> sector, Grässlin relies on established<br />
distributors and authorized wholesalers. Close cooperation<br />
with our local distributors enables Grässlin to more quickly<br />
recognize customer requirements and react to change<br />
accordingly. The first-class services of our distributors<br />
plus our high-quality products have been winning over our<br />
customers for years.<br />
In the same way, Grässlin has been able to expand and soli-<br />
dify its position as a market lea<strong>de</strong>r in the industrial sector for<br />
years in many countries. Tailored solutions combined with<br />
professional expertise and support are the prime contributors<br />
to our shared success.<br />
105<br />
Service /In<strong>de</strong>x
106<br />
in<strong>de</strong>x<br />
overview follow-up types<br />
Designation old Designation eAN-Co<strong>de</strong><br />
4010940<br />
AS 08..<br />
AS 09..<br />
AS 41..<br />
C<br />
ord.-No. Voltage Page Follow-up type Page<br />
to be purchased through: Frensch GmbH, Dahlingstrasse 119, 47229 Duisburg<br />
Tel. 0 20 65/25 58-0 Fax: 0 20 65/25 58-20<br />
E-Mail: info@frensch.<strong>de</strong>, internet: www.frensch.<strong>de</strong><br />
Chronostat 2ST – – – – – famoso 500 70<br />
Chronostat 2SW – – – – – famoso 550 70<br />
Chronostat 3 – – – – – famoso 500 70<br />
Chronostat 300 – – – – – famoso 500 70<br />
Chronostat 301 – – – – – famoso 550 70<br />
Chronostat 4E QRT – – – – – famoso 500 70<br />
Chronostat 4E QRW – – – – – famoso 550 70<br />
Chronostat 6E – – – – – famoso 1000 –<br />
Chronostat 8E – – – – – famoso 1000 –<br />
Chronostat 9E – – – – – famoso 1000 –<br />
Chronostat 400 – – – – – famoso 800 –<br />
Chronostat 450 – – – – – famoso 850 –<br />
Chronostat 700 – – – – – famoso 500 70<br />
Chronostat 750 – – – – – famoso 550 70<br />
Chronostat 900 – – – – – famoso 1000 –<br />
Chronostat 1000<br />
D<br />
– – – – – famoso 1000 –<br />
digi 12-45 – – – – – talento 371 plus 22<br />
digi 12-72 without base – – – – – tactic 571.1 plus 52<br />
digi 16-72/1<br />
–<br />
– – – – MIL D150 (without base)<br />
tactic 571.1 plus<br />
56<br />
52<br />
digi 32-72/2 – – – – tactic 572.1 plus 52<br />
digi 56-45/1 – – – – – talento 371 plus 22<br />
digi 56-45/2 – – – – – talento 372 plus 22<br />
digi 56-72/1<br />
–<br />
– – – – MIL D150 (without base)<br />
tactic 571.1 plus<br />
56<br />
52<br />
digi 56-72/2 – – – – – tactic 572.1 plus 52<br />
digi 56-19 – – – – – –<br />
digi 56-69 – – – – – –<br />
digi 127 – – – – – talento 994 –<br />
digi 128-45/4 – – – – – talento 994 –<br />
DS 053 – – – – – turnus 501 84<br />
DS 053u<br />
e<br />
– – – – – turnus 501 84<br />
Easy Prog.<br />
F<br />
– – – – – talento taxxi plus 34<br />
famoso 2000 – – – – – famoso 1000 –<br />
famoso 1000 – 030957 04.50.0001.1 2 x 1,5 V – – –<br />
famoso 1000 rf set – 032807 04.51.0002.1 2 x 1,5 V – – –<br />
famoso 1000 rf T – 030964 04.51.0001.1 2 x 1,5 V – – –<br />
FM/1 digi 16 – – – – – FMD 120 52<br />
FM/1 digi 20<br />
m<br />
– – – – – FMD 120 52<br />
MIL/1 digi 42 – – – – – MIL D150 56<br />
MIL 01T/1 digi 16 – – – – – tasu 672 plus 96<br />
MIL 01T/1QRTuZ – – – – – tasu 511 96<br />
MIL 96/4 digi 322 F – – – – – talento 994 –<br />
MIL 96/4 digi 322JF – – – – – talento 994 –<br />
MIL 96/4 digi 322JFPD – – – – – talento 994 –<br />
MIL 2001 F1hu – = MIL 2008 SF 1hu – – – 2) talento 121 38<br />
MIL 2001 FRT – – – – – 1) tactic 211.1 46<br />
MIL 2001 FRTu – = MIL 2008 QFRTu – – – 1) tactic 211.1<br />
46<br />
tactic 571.1 plus<br />
52<br />
MIL 2001 FRW – – – – – 1) tactic 271.1 46<br />
MIL 2001 FRWu – = MIL 2008 QFRWu – – – 1) tactic 271.1<br />
46<br />
tactic 571.1 plus<br />
52<br />
MIL 2001 FT –<br />
= MIL 2008 SFTu –<br />
–<br />
– MIL/1 QRTuZH<br />
56<br />
–<br />
–<br />
–<br />
tactic 111.1<br />
46<br />
MIL 2001 FTu –<br />
= MIL 2008 SFTu –<br />
–<br />
– MIL/1 QRWuZH<br />
56<br />
–<br />
–<br />
–<br />
tactic 111.1<br />
46<br />
MIL 2001 FW – = MIL 2008 SFWu – – – MIL/1 QRWuZH<br />
56<br />
tactic 171.1<br />
46<br />
MIL 2001 FWu<br />
–<br />
= MIL 2008 SFWu – – – MIL/1 QRWuZH<br />
tactic 171.1<br />
56<br />
46<br />
MIL 2002 QRTuJu – – – – – talento 994 –<br />
MIL 2002 QRTuTu – – – – – tactic 572.1 plus 52<br />
MIL 2002 QRTuWu – – – – – tactic 572.1 plus 52<br />
MIL 2008 QFRTu – – – – – tactic 211.1 46<br />
MIL 2008 QFRWu – – – – – tactic 271.1 46<br />
MIL 2008 QFRTu – – – – – MIL/1 QRTuZH 56<br />
MIL 2008 QFRWu – – – – – MIL/1 QRWuZH 56<br />
MIL 2008 QFRT – – – – – tactic 211.1 46<br />
MIL 2008 QFRW – – – – – tactic 271.1 46
overview follow-up types<br />
Designation old Designation eAN-Co<strong>de</strong><br />
4010940<br />
ord.-No. Voltage Page Follow-up type Page<br />
MIL 2008 QMRT – B1 bis B7<br />
MIL 2008 QMRTu – B1 bis B7<br />
MIL 2008 QMRW – B1 bis B7<br />
For customized mo<strong>de</strong>ls, please contact manufacturer directly.<br />
MIL 2008 QMRWu – B1 bis B7<br />
MIL 2008 QMT – B1 bis B7<br />
MIL 2008 SFTu<br />
–<br />
– – – – MIL/1 QRTuZH<br />
tactic 111.1<br />
56<br />
46<br />
MIL 2008 SFWu<br />
–<br />
– – – – MIL/1 QRWuZH<br />
tactic 271.1<br />
56<br />
46<br />
MIL 2008 SF1hu – – – – – 2) talento 121 38<br />
MIL 2008 SFT<br />
–<br />
– – – – MIL/1 QRTuZH<br />
tactic 111.1<br />
56<br />
46<br />
MIL 2008 SFW<br />
–<br />
– – – – MIL/1 QRWuZH<br />
tactic 271.1<br />
56<br />
46<br />
MIL 2008 SMT – B1 and B2<br />
MIL 2008 SMTu<br />
MIL 2008 SMW<br />
–<br />
–<br />
B1 and B2<br />
B1 and B2<br />
For customized mo<strong>de</strong>ls, please contact manufacturer directly.<br />
MIL 2008 SMWu<br />
R<br />
– B1 and B2<br />
RKU 300 – – – – – famoso 500 70<br />
RKU 300-1 – – – – – famoso 500 70<br />
RKU 300-5<br />
S<br />
– – – – – famoso 500 70<br />
STA-E – – – – – topica 600 94<br />
STA-PT – – – – – topica 400S 94<br />
STA-PW – – – – – topica 450S 94<br />
STA-T – – – – – topica 200S 94<br />
STA-W – – – – – topica 450S 94<br />
SU-RT – – – – – tactic 211.1 46<br />
SU-RTT – – – – – tactic 572.1 plus 50<br />
SU-RTTT – – – – – talento 893 –<br />
SU-RTu – – – – – tactic 211.1 46<br />
SU-RTuT – – – – – tactic 572.1 plus 50<br />
SU-RTuTT – – – – – talento 893 –<br />
SU-RTuTu – – – – – tactic 572.1 plus 50<br />
SU-RTuTuT – – – – – talento 893 –<br />
SU-RWT – – – – – tactic 572.1 plus 50<br />
SU-RWTT – – – – – talento 893 –<br />
SU-RWTu – – – – – tactic 572.1 plus 50<br />
SU-RWuTT – – – – – talento 893 –<br />
SU-RWuTu – – – – – tactic 572.1 plus 50<br />
SU-RWuTuT – – – – – talento 893 –<br />
SU-TT – – – – – tactic 572.1 plus 50<br />
SU-TTT – – – – – talento 893 –<br />
SU-TuT – – – – – tactic 572.1 plus 50<br />
SU-TuTT – – – – – talento 893 –<br />
SU-TuTu – – – – – tactic 572.1 plus 50<br />
SU-TuTuT – – – – – talento 893 –<br />
SU-W – – – – – tactic 271.1 46<br />
SU-RW – – – – – tactic 271.1 46<br />
SU-Wu – – – – – tactic 271.1 46<br />
SU-RWu – – – – – tactic 271.1 46<br />
SU-WT – – – – tactic 572.1 plus 50<br />
SU-WTT – – – – – talento 993 –<br />
SU-WTu – – – – – tactic 572.1 plus 50<br />
SU-WuTT – – – – – talento 993 –<br />
SU-WuTu – – – – – tactic 572.1 plus 50<br />
SU-WuTuT<br />
T<br />
– – – – – talento 993 –<br />
tactic 571.1 – – – 220-240 V / 50-60 Hz – tactic 571.1 plus 50<br />
tactic 571.1 – – – 24 V AC/DC – tactic 571.1 plus 50<br />
tactic 572.1 – – – 220-240V / 50-60 Hz – tactic 572.1 plus 50<br />
tactic 572.1 – – – 100-120 V / 50-60 Hz – tactic 572.1 plus 50<br />
tactic 572.1 – – – 24 V AC/DC – tactic 572.1 plus 50<br />
talento 371 – – – 220-240 V / 50-60 Hz – talento 371 plus 22<br />
talento 371 – – – 100-120 V / 50-60 Hz – talento 371 plus 22<br />
talento 371 – – – 24 V AC/DC – talento 371 plus 22<br />
talento 371 – – – 12 V AC/DC – talento 371 plus 22<br />
talento 371 mini – – – 220-240 V / 50-60 Hz – talento 371 mini plus 22<br />
talento 372 – – – 220-240 V / 50-60 Hz – talento 372 plus 22<br />
talento 372 – – – 100-120 V / 50-60 Hz – talento 372 plus 22<br />
talento 372 – – – 24 V AC/DC – talento 372 plus 22<br />
talento 372 – – – 12 V AC/DC – talento 372 plus 22<br />
talento 471 – – – 220-240 V / 50-60 Hz – talento 471 plus 24<br />
talento 472 – – – 220-240 V / 50-60 Hz – talento 472 plus 24<br />
talento 671 – – – 220-240 V / 50-60 Hz – talento 671 plus DCF 24<br />
in<strong>de</strong>x<br />
107<br />
Service /In<strong>de</strong>x
108<br />
in<strong>de</strong>x<br />
overview follow-up types<br />
Designation old Designation eAN-Co<strong>de</strong><br />
4010940<br />
ord.-No. Voltage Page Follow-up type Page<br />
talento 672 – – – 220-240 V / 50-60 Hz – talento 471 plus<br />
24<br />
talento 671 plus DCF<br />
24<br />
talento 891 – – – 230 V / 50-60 Hz – talento 892 plus 30<br />
talento 892 – – – 230 V / 50-60 Hz – talento 892 plus 30<br />
talento 893 – – – 230 V / 50-60 Hz – talento 892 plus + CE 30/32<br />
talento 894 – – – 230 V / 50-60 Hz – talento 892 plus + CE 30/32<br />
talento 894 – – – 100-120 V / 50-60 Hz – talento 892 plus + CE 30/32<br />
talento 894 – – – 24 V AC/DC – talento 892 plus + CE 30/32<br />
talento 991 V86/1 digi 322 JF – – 230 V / 50-60 Hz – talento 992 plus 30<br />
talento 992 V86/2 digi 322 JF – – 230 V / 50-60 Hz – talento 992 plus 30<br />
talento 993 V86/3 digi 322 JF – – 230 V / 50-60 Hz – talento 992 plus + CE 30/32<br />
talento 994 V86/3 digi 322 JF – – 230 V / 50-60 Hz – talento 992 plus + CE 30/32<br />
talento 994 V86/3 digi 322 JF – – 100-120 V / 50-60 Hz – talento 992 plus + CE 30/32<br />
talento 994 V86/3 digi 322 JF – – 24 V AC/DC – talento 992 plus + CE 30/32<br />
talento taxxi – – – – – talento taxxi plus 34<br />
tasu 472 – – – 220-240 V / 50-60 Hz – tasu 672 plus 96<br />
taxxo 212 UWZ 52 KE 001513 05.15.1090.1 220-240 V / 50 Hz – – –<br />
taxxo 212 UWZ 52 KE 001544 05.15.1105.1 110-120 V / 50 Hz – – –<br />
taxxo 332 UWZ 60 ZKE 001568 05.15.1108.1 220-240 V / 50 Hz – – –<br />
tip 100 S – – – – – – –<br />
topica 500 – – – 220-240 V / 50 Hz – topica 600 94<br />
topica digi – – – – – – –<br />
trealux 200 – – – – – trealux 210 82<br />
trealux 400 – – – – – trealux 210 82<br />
turnus 771 – – – 230 V / 50-60 Hz – turnus 771 plus 86<br />
turnus 772<br />
U<br />
– – – 230 V / 50-60 Hz – turnus 772 plus 86<br />
UNI 45 1hA – – – – – – –<br />
UNI 45 1hV – – – – – – –<br />
UNI 45 TV – – – – – – –<br />
UNI 45 WA – – – – – – –<br />
UNI 45 WV – – – – – talento 171 38<br />
UTR 310 – – – – – famoso 500 70<br />
UTR 310-1 – – – – – famoso 500 70<br />
UTR 310-2 – – – – – famoso 500 70<br />
UWZ 45 V<br />
V<br />
– – – – – taxxo 403 98<br />
V6 RTT – – – – – talento 212 40<br />
V6 RTuT – – – – – talento 212 40<br />
V6 RTuTu – – – – – talento 212 40<br />
V6 RTW – – – – – talento 202 40<br />
V6 RTuW – – – – – talento 202 40<br />
V6 RTWu – – – – – talento 202 40<br />
V6 RTuWu – – – – – talento 202 40<br />
V6 TT – – – – – talento 212 40<br />
V6 TuT – – – – – talento 212 40<br />
V6 TuTu – – – – – talento 212 40<br />
V6 TW – – – – – talento 202 40<br />
V6 TuW – – – – – talento 202 40<br />
V6 TWu – – – – – talento 202 40<br />
V6 TuWu – – – – – talento 202 40<br />
V72 1h – – – – – talento 121 38<br />
V72 1hu – – – – – talento 121 38<br />
V73 QRTu – – – – – talento 211 40<br />
V72 QRWu – – – – – talento 271 40<br />
V72 RT – – – – – talento 211 40<br />
V72 RTu – – – – – talento 211 40<br />
V72 RW – – – – – talento 271 40<br />
V72 RWu – – – – – talento 271 40<br />
V72 T – – – – – talento 111 38<br />
V72 W – – – – – talento 171 38<br />
V72 Wu – – – – – talento 171 38<br />
V73 1hu – – – – – talento 121 38<br />
V73 Tu – – – – – talento 111 38<br />
V73 Wu – – – – – talento 171 38<br />
V86/1 digi 12 – – – – – talento 371 plus 22<br />
V86/1 digi 20 – – – – – talento 371 plus 22<br />
V86/1 digi 42 – – – – – talento 371 plus 22<br />
V86/1 digi 42 M1 – – – – – talento 371 mini plus 22<br />
V86/1 digi 322 F – – – – – talento 992 plus 30<br />
V86/1 digi 322 JF – – – – – talento 992 plus 30<br />
V86/1 DS 2 – – – – – turnus 501 84<br />
V86/1 DSC 16 – – – – – turnus 771 –<br />
V86/1 QRT M1 – – – – – talento 211 mini 40<br />
V86/1 QRTu – – – – – talento 211 40<br />
V86/1 QRWu – – – – – talento 271 40<br />
V86/1 S1hu – – – – – talento 121 38
overview follow-up types<br />
Designation old Designation eAN-Co<strong>de</strong><br />
4010940<br />
V86/1 ST M1 – – – – – talento 111 mini 38<br />
V86/1 STu – – – – – talento 111 38<br />
V86/1 SWu – – – – – talento 171 38<br />
V86/2 digi 32 M2 – – – – – talento 372 plus 22<br />
V86/2 digi 322 F – – – – – talento 992 plus 30<br />
V86/2 digi 322 JF – – – – – talento 992 plus 30<br />
V86/2 digi 322 JF IR – – – – – talento 992 plus 30<br />
V86/2 digi 42 – – – – – talento 372 plus 22<br />
V86/2 DS 3 – – – – – turnus 502 84<br />
V86/2 DS 3.0 – – – – – turnus 502 84<br />
V86/2 DSC 32 – – – – – turnus 772 plus 86<br />
V86/2 DSC 32.0 – – – – – turnus 772 plus 86<br />
V86/2 QRTuTu – – – – – talento 212 40<br />
V86/2 STuTu – – – – – talento 212 40<br />
V86/2 STuWu – – – – – talento 202 40<br />
V86/3 digi 322 F – – – – – talento 992 plus + CE 30/32<br />
V86/4 digi 322 F – – – – – talento 992 plus + CE 30/32<br />
V86/4 digi 322 JF – – – – – talento 992 plus + CE 30/32<br />
V86/4 digi 322 JF IR – – – – – talento 992 plus + CE 30/32<br />
1) Installation dimensions are i<strong>de</strong>ntical. Easy replacement in switch cabinet.<br />
Because of diverse assignment of connectors, rewiring and new socket necessary.<br />
2) Replacement through DIN-rail mounting or phase out type MIL 2008, UNI45 1hE while stocks last.<br />
ord.-No. Voltage Page Follow-up type Page<br />
in<strong>de</strong>x<br />
109<br />
Service /In<strong>de</strong>x
110<br />
in<strong>de</strong>x<br />
Product directory<br />
ord.-No. eAN-Co<strong>de</strong> Designation Voltage Page<br />
Assembly kit 024093 16.58.0004.2 96<br />
Attachment bracket 024086 16.58.0016.6 96<br />
Attachment screw 003296 50.22.0001.5 56<br />
Base 002862 15.92.0021.4 100<br />
Base 003265 50.92.0013.4 56<br />
Base 003265 50.92.0013.4 56<br />
Base (1-Channel) 003340 01.78.0002.2 57<br />
Base (2-Channel) 002718 03.52.0003.2 56<br />
Blen<strong>de</strong> 72 x 72 008819 16.26.0006.4 100<br />
Cap LF 029166 07.02.0003.2 500-10.000 Lux 86<br />
Cover 55 x 55 008802 05.15.0065.6 100<br />
EMD 120 039424 03.85.0003.1 3,4-6 V DC 54<br />
EMD 220 040123 03.85.0005.1 3,4-6 V DC 54<br />
EMD 250 039448 03.86.0003.1 3,4-6 V DC 54<br />
famoso 500 020231 04.34.0001.1 230 V / 50-60 Hz 70<br />
famoso 505 027421 04.34.0005.1 230 V / 50-60 Hz 70<br />
famoso 550 020224 04.34.0002.1 230 V / 50-60 Hz 70<br />
famoso 555 027438 04.34.0006.1 230 V / 50-60 Hz 70<br />
famoso 601 022709 04.40.0008.1 2 X 1,5 V 70<br />
famoso 601 rf 037444 04.53.0002.1 2 X 1,5 V 64<br />
famoso 601 rf set<br />
(Transmitter + Receiver)<br />
037437 04.53.0001.1 2 X 1,5 V 230 V / 50-60 Hz 64<br />
famoso 651 rf 037468 04.53.0004.1 2 X 1,5 V 64<br />
famoso 651 rf set 037451 04.53.0003.1 2 X 1,5 V 230 V / 50-60 Hz 64<br />
feeling D 101 anthracite 039929 04.10.0002.1 2 x 1,5 V 68<br />
feeling D 101 rf anthracite 039950 04.11.0002.1 2 x 1,5 V 62<br />
feeling D 101 rf set anthracite 039981 04.11.0005.1 2 x 1,5 V 230 V / 50-60 Hz 62<br />
feeling D 101 rf set silver 039998 04.11.0006.1 2 x 1,5 V 230 V / 50-60 Hz 62<br />
feeling D 101 rf set white 039974 04.11.0004.1 2 x 1,5 V 230 V / 50-60 Hz 62<br />
feeling D 101 rf silver 039968 04.11.0003.1 2 x 1,5 V 62<br />
feeling D 101 rf white 039943 04.11.0001.1 2 x 1,5 V 62<br />
feeling D 101 silver 039936 04.10.0003.1 2 x 1,5 V 68<br />
feeling D 101 white 039578 04.10.0001.1 2 x 1,5 V 68<br />
Flush mounting socket 002831 01.79.0002.2 57<br />
FM/1 QRTuZH 000592 02.76.0075.1 230 V AC / 130 V DC 48<br />
FM/1 QRWuZH 000608 02.76.0076.1 230 V AC / 130 V DC 48<br />
FM/1 rf 040710 04.52.0014.1 230 V / 50 - 60 Hz 66<br />
FM/1 STuZH 000264 01.76.0088.1 220-240 V / 50-60 Hz 48<br />
FM/1 SWuZH 000271 01.76.0089.1 220-240 V / 50-60 Hz 48<br />
FMD 120 037949 03.58.0017.1 220-240 V / 50 Hz 52<br />
FMD 150 037970 03.60.0011.1 230 V / 50-60 Hz 52<br />
FMD 220 037963 03.58.0019.1 220-240 V / 50 Hz 52<br />
Food countainer 017316 85.21.0002.4 96<br />
Food countainer 017316 85.21.0002.4 96<br />
Frame 003272 50.13.0002.4 56<br />
Frame 035044 04.46.0038.6 74<br />
Frame 002763 03.52.0006.6 57<br />
Glass 003302 50.13.0001.3 56<br />
Glass 011215 01.76.0054.6 57<br />
Glass 037567 01.46.0082.6 57<br />
Glass 017323 85.13.0001.3 96<br />
Glass 017323 85.13.0001.3 96<br />
Installation frame 021726 03.59.0047.2 42 / 88<br />
Lithium battery 6 years running reserve 032821 09.02.0012.8 42<br />
MIL D150 038588 03.87.0011.1 220-240 V / 50-60 Hz 56<br />
MIL/1 QRTuZH 015671 02.45.0001.1 230 V AC / 130 V DC 56<br />
MIL/1 QRTuZH 015695 02.45.0003.1 30 V AC / 12 V DC 56<br />
MIL/1 QRWuZH 016142 02.45.0004.1 230 V AC / 130 V DC 56<br />
Mounting plate for rail 002770 01.46.0334.2 57<br />
Plug-in ri<strong>de</strong>rs 024079 85.15.0006.4 96<br />
Plug-in ri<strong>de</strong>rs 024079 85.15.0006.4 96<br />
Radio antenna FA DCF 77 021184 07.01.0028.1 34<br />
Radio antenna FA GPS 034856 07.75.0008.1 34<br />
Ratchet clamp 002985 14.27.0002.4 100<br />
Ratchet clampe 002886 15.27.0011.4 57 / 100<br />
Rec Tip rf 038496 04.52.0006.1 220 - 240 V AC 66<br />
RecUNO 031220 04.52.0001.1 230 V / 50-60 Hz 66<br />
rondomatic 400 (automatic fish fee<strong>de</strong>r) 003364 16.58.0001.1 230 V / 50-60 Hz 96<br />
Seal 002848 01.45.0017.6 57<br />
Sealing 002978 11.24.0007.8 100<br />
Sealing 002992 14.24.0001.5 100<br />
Sealing glass 003210 46.13.0002.4 57<br />
Sealing IP 54 011253 11.24.0008.8 100<br />
Sealing screw 013769 16.10.0011.8 57<br />
Sensor LF 002671 07.02.0001.1 2-500 Lux 86<br />
Sensor LF 027643 07.02.0004.1 500-10.000 Lux 86<br />
Sensor LF flush mounting 016630 07.02.0003.1 2-500 Lux 86
Product directory<br />
ord.-No. eAN-Co<strong>de</strong> Designation Voltage Page<br />
set talento taxxi plus 034924 07.75.0012.1 34<br />
Spring clip 002961 05.20.0026.6 100<br />
SU/1 QRTuZH 004347 02.05.0001.1 220-240 V / 50-60 Hz 56<br />
Surface mounting housing 002879 50.12.0001.4 100<br />
tactic 111.1 003975 01.80.0001.1 220-240 V / 50 Hz 46<br />
tactic 171.1 003982 01.80.0002.1 220-240 V / 50 Hz 46<br />
tactic 211.1 004019 02.80.0001.1 230 V AC / 130 V DC 46<br />
tactic 271.1 004026 02.80.0002.1 230 V AC / 130 V DC 46<br />
tactic 371.1 plus 038007 03.62.0001.1 230 V / 50-60 Hz 50<br />
tactic 372.1 plus 038014 03.62.0002.1 230 V / 50-60 Hz 50<br />
tactic 571.1 plus 038038 03.87.0002.1 24 V AC/DC 50<br />
tactic 571.1 plus 038021 03.87.0001.1 230 V / 50-60 Hz 50<br />
tactic 572.1 plus 038069 03.87.0005.1 24 V AC/DC 50<br />
tactic 572.1 plus 038076 03.87.0006.1 12 V AC/DC 50<br />
tactic 572.1 plus 038045 03.87.0003.1 230 V / 50-60 Hz 50<br />
tactic 572.1 plus 038052 03.87.0004.1 110-120 V / 50-60 Hz 50<br />
talento 111 020668 01.28.0001.1 220-240 V / 50 Hz 38<br />
talento 111 mini 022556 01.06.0004.1 220-240 V / 50 Hz 38<br />
talento 121 020682 01.28.0003.1 220-240 V / 50 Hz 38<br />
talento 171 020675 01.28.0002.1 220-240 V / 50 Hz 38<br />
talento 202 020767 02.28.0008.1 230 V AC / 130 V DC 40<br />
talento 211 020750 02.28.0001.1 230 V AC / 130 V DC 40<br />
talento 211 020736 02.28.0003.1 30 V AC / 12 V DC 40<br />
talento 211 020743 02.28.0002.1 130 V AC / 60 V DC 40<br />
talento 211 mini 022563 02.03.0003.1 230 V AC / 110 V DC 40<br />
talento 212 020699 02.28.0007.1 230 V AC / 130 V DC 40<br />
talento 261 026325 02.28.0015.1 230 V AC / 130 V DC 40<br />
talento 271 020712 02.28.0005.1 130 V AC / 60 V DC 40<br />
talento 271 020729 02.28.0004.1 230 V AC / 130 V DC 40<br />
talento 271 020705 02.28.0006.1 30 V AC / 12 V DC 40<br />
talento 371 mini plus 034078 03.72.0001.1 230 V / 50-60 Hz 22<br />
talento 371 plus 033989 03.73.0004.1 24 V AC/DC 22<br />
talento 371 plus 033910 03.73.0001.1 230 V / 50-60 Hz 22<br />
talento 371 plus 033972 03.73.0005.1 110-120 V / 50-60 Hz 22<br />
talento 372 plus 034016 03.73.0007.1 24 V AC/DC 22<br />
talento 372 plus 033996 03.73.0003.1 12 V AC/DC 22<br />
talento 372 plus 033927 03.73.0002.1 230 V / 50-60 Hz 22<br />
talento 372 plus 034023 03.73.0008.1 110-120 V / 50-60 Hz 22<br />
talento 471 plus 034054 03.75.0005.1 110-120 V / 50-60 Hz 24<br />
talento 471 plus 033941 03.75.0001.1 230 V / 50-60 Hz 24<br />
talento 472 plus 033958 03.75.0002.1 230 V / 50-60 Hz 24<br />
talento 472 plus 034061 03.75.0006.1 110-120 V / 50-60 Hz 24<br />
talento 671 plus, DCF 034047 03.75.0004.1 110-120 V / 50-60 Hz 24<br />
talento 671 plus, DCF 033965 03.75.0003.1 230 V / 50-60 Hz 24<br />
talento 791 plus 034818 03.74.0001.1 230 V / 50-60 Hz 26<br />
talento 791 plus DCF 034832 03.74.0003.1 230 V / 50-60 Hz 26<br />
talento 792 plus 034825 03.74.0002.1 230 V / 50-60 Hz 26<br />
talento 892 plus 034153 03.76.0004.1 110/230 V / 50-60 Hz 30<br />
talento 892 plus 034221 03.76.0011.1 24 V AC/DC 30<br />
talento 992 plus DCF 034146 03.76.0003.1 230 V / 50-60 Hz 30<br />
talento CE plus 034764 07.75.0003.1 110/230 V / 50-60 Hz 32<br />
talento IR plus 034931 07.75.0013.1 28<br />
talento LAN plus 034894 07.75.0009.1 230 V / 50-60 Hz 32<br />
talento taxxi plus 034917 07.75.0011.1 34<br />
talento VM plus 034948 07.75.0014.1 24 V AC/DC 28<br />
talento VM plus 034740 07.75.0001.1 230 V / 50-60 Hz 28<br />
talento VM plus 034757 07.75.0002.1 110-120 V / 50-60 Hz 28<br />
tasu 511 (MIL 02T/1 QRTUZ) 013974 02.08.0001.1 230 V AC / 130 V DC 96<br />
tasu 672 plus (MIL 02T D250) 038557 03.87.0010.1 220-240 V / 50-60 Hz 96<br />
taxxo 100 (UWZ 48 A) 001377 05.15.1010.1 18-26 V / 50 Hz 98<br />
taxxo 100 (UWZ 48 A) 001452 05.15.1049.1 36-48 V / 50 Hz 98<br />
taxxo 100 (UWZ 48 A) 001438 05.15.1026.1 110-127 V / 60 Hz 98<br />
taxxo 100 (UWZ 48 A) 001339 05.15.1001.1 220-240 V / 50 Hz 98<br />
taxxo 100 (UWZ 48 A) 001506 05.15.1089.1 330-380 V / 50 Hz 98<br />
taxxo 100 (UWZ 48 A) 001407 05.15.1019.1 110-120 V / 50 Hz 98<br />
taxxo 112 (UWZ 48 KED) 002268 05.15.1038.1 220-240 V / 50 Hz 98<br />
taxxo 112 (UWZ 48 KED) 002282 05.15.1118.1 110-120 V / 50 Hz 98<br />
taxxo 112 (UWZ 48 KED) 002275 05.15.1016.1 18-26 V / 50 Hz 98<br />
taxxo 112 (UWZ 48 KED) 002299 05.15.1031.1 110-127 V / 60 Hz 98<br />
taxxo 403 (UWZ 35 V) 001797 05.21.0003.1 36-48 V / 50 Hz 98<br />
taxxo 403 (UWZ 35 V) 001803 05.21.0004.1 18-26 V / 50 Hz 98<br />
taxxo 403 (UWZ 35 V) 001773 05.21.0001.1 220-240 V / 50 Hz 98<br />
taxxo 403 (UWZ 35 V) 001780 05.21.0002.1 110-120 V / 50 Hz 98<br />
taxxo 403 (UWZ 35 V) 001810 05.21.0009.1 110-127 V / 60 Hz 98<br />
taxxo 612 (FWZ 36 K) 001667 05.20.0016.1 18-26 V / 50 Hz 98<br />
taxxo 612 (FWZ 36 K) 001742 05.20.0033.1 330-380 V / 50 Hz 98<br />
taxxo 612 (FWZ 36 K) 001599 05.20.0006.1 220-240 V / 50 Hz 98<br />
in<strong>de</strong>x<br />
111<br />
Service /In<strong>de</strong>x
112<br />
in<strong>de</strong>x<br />
Product directory<br />
ord.-No. eAN-Co<strong>de</strong> Designation Voltage Page<br />
taxxo 712 (FWZ 55 K) 001681 05.20.0018.1 18-26 V / 50 Hz 98<br />
taxxo 712 (FWZ 55 K) 001711 05.20.0028.1 36-48 V / 50 Hz 98<br />
taxxo 712 (FWZ 55 K) 001728 05.20.0029.1 110-120 V / 50 Hz 98<br />
taxxo 712 (FWZ 55 K) 001629 05.20.0008.1 110-127 V / 60 Hz 98<br />
taxxo 712 (FWZ 55 K) 001582 05.20.0004.1 220-240 V / 50 Hz 98<br />
Terminal cover (1-Channel) 002817 01.78.0004.6 57<br />
Terminal cover (2-Channel) 002749 01.96.0043.6 57<br />
thermio 102 019488 04.46.0004.1 230 V / 50-60 Hz 74<br />
thermio 103 019464 04.46.0006.1 230 V / 50-60 Hz 74<br />
thermio 402 019495 04.46.0003.1 230 V / 50-60 Hz 74<br />
thermio 403 019471 04.46.0005.1 230 V / 50-60 Hz 74<br />
thermio 513 019167 04.46.0001.1 230 V / 50-60 Hz 74<br />
thermio 603 041328 04.46.0016.1 2 X 1,5 V 76<br />
thermio 703 041335 04.46.0017.1 230 V AC / 50 Hz 76<br />
thermio 713 041342 04.46.0018.1 230 V AC / 50 Hz 76<br />
thermio E 033231 04.46.0014.1 24 V / 50-60 Hz 74<br />
thermio touch 041359 04.46.0019.1 2 X 1,5 V 76<br />
topica 200 S 002428 16.25.0008.1 220-240 V / 50-60 Hz 94<br />
topica 400 S 002435 16.26.0008.1 220-240 V / 50-60 Hz 94<br />
topica 410 S 016241 16.27.0001.1 220-240 V / 50-60 Hz 94<br />
topica 450 S 003906 16.40.0001.1 220-240 V / 50-60 Hz 94<br />
topica 600 039387 16.15.0001.1 230 V / 50-60 Hz 94<br />
trealux 210 024789 18.13.0009.1 230 V / 50-60 Hz 82<br />
trealux 510 039127 18.13.0016.1 220-240 V / 50-60 Hz 82<br />
turnus 200 018986 18.17.0001.1 220-240 V / 50-60 Hz 84<br />
turnus 501 A 023249 18.18.0001.1 230 V / 50-60 Hz 84<br />
turnus 501 E 024031 18.18.0006.1 230 V / 50-60 Hz 84<br />
turnus 502 A 023256 18.18.0002.1 230 V / 50-60 Hz 84<br />
turnus 502.1 023973 18.18.0003.1 230 V / 50-60 Hz 84<br />
turnus 771 plus 040420 18.22.0001.1 230 V / 50-60 Hz 86<br />
turnus 772 plus 040437 18.22.0002.1 230 V / 50-60 Hz 86<br />
UNI 45 1hE 000226 01.50.0013.1 220-240 V / 50 Hz 56<br />
UNI 45 TE 000202 01.50.0002.1 220-240 V / 50 Hz 56<br />
UNI 45 WE 003333 01.50.0076.1 220-240 V / 50 Hz 56
noTiZen<br />
113<br />
Service /In<strong>de</strong>x
114<br />
noTiZen