STANDARD SANITATION OPERATING PROCEDURE (SSOP)<br />

FOR THE CONTROL OF SANITATION IN THE MANUFACTURE OF<br />

<strong>VITAMIN</strong> A FORTIFIED <strong>PEANUT</strong> <strong>BUTTER</strong> 1<br />

(Name <strong>of</strong> Company)<br />

(Address <strong>of</strong> Company)<br />

CONTROL NO I. SAFETY OF WATER SUPPLY.<br />

A. Objective:<br />

To ensure a consistent supply <strong>of</strong> an adequate volume <strong>of</strong> potable water for use in food processing and<br />

other operations in a food plant. It includes water used in processing, personnel hygiene and<br />

cleaning <strong>of</strong> equipment and facilities.<br />

B. Procedure:<br />

1. Water supply source: Water should be supplied from a source that meets the standards shown<br />

in Appendix A. It should be analyzed by a reputable laboratory to check compliance with the<br />

standards. Deep well water should be checked for possible cross contamination by ground water<br />

and/ or during handling, prior to and when delivered to the plant.<br />

2. Evaluation <strong>of</strong> water quality and potability: <strong>The</strong> water supply is checked daily for physical<br />

characteristics and monthly for microbiological quality. <strong>The</strong> procedure for evaluating the water<br />

for physical characteristics is in Appendix B. <strong>The</strong> results <strong>of</strong> evaluation are recorded in numbers<br />

1.2 – 1.5 in Record No 1, Appendix C. <strong>The</strong> procedure for evaluating for microbiological quality<br />

is in Appendix D. Results are recorded in the Report <strong>of</strong> Microbiological Analysis, Record No.<br />

2, Appendix E.<br />

3. Treatment with chlorine: <strong>The</strong> water should be treated to ensure its potability at all times, such<br />

as chlorination. If chlorine treatment is used, the chlorine level <strong>of</strong> the water should be<br />

maintained at 0.25 to 1.0 ppm (WHO, 1984). A procedure for water chlorination is in Appendix<br />

F.<br />

4. Inspection and maintenance <strong>of</strong> chlorine level: <strong>The</strong> required level <strong>of</strong> chlorine should be<br />

maintained by Engineering personnel. It is also checked daily by the assigned Quality Control<br />

personnel (QC personnel) every production shift or once a day if there is no processing<br />

operation. A procedure for checking the chlorine level is shown in Appendix G. Results <strong>of</strong><br />

inspections are recorded in number 1.1 in the Daily Sanitation Inspection Checklist, Record No<br />

1, Appendix C.<br />

<strong>The</strong> detection <strong>of</strong> a low chlorine level at anytime is immediately reported by assigned QC<br />

personnel to Engineering personnel through a Communication Slip, Record No. 3, Appendix H.<br />

Chlorine should be manually added immediately by Engineering or QC personnel or the<br />

production is stopped if the level required is not reached immediately. Engineering should<br />

check the water chlorinator machine and other possible sources <strong>of</strong> the problem and take action to<br />

ensure that the required chlorine level is reached.<br />

174