24.04.2013 Views

VITAMIN A FORTIFIed PEANUT BUTTER - The Official Website of ...

VITAMIN A FORTIFIed PEANUT BUTTER - The Official Website of ...

VITAMIN A FORTIFIed PEANUT BUTTER - The Official Website of ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Process Flow for the Vitamin A Fortification <strong>of</strong> Peanut Butter<br />

1. Prepare the peanut butter for receiving the fortificant according to the procedure described in Steps 1 to<br />

3 <strong>of</strong> the process flow for the stabilization <strong>of</strong> a flowing-type peanut butter shown in Appendix A.<br />

2. Weigh the following amounts <strong>of</strong> peanut butter matrix, stabilizer and vitamin A fortificant in separate<br />

containers: 6 Kg peanut butter in a mixing bowl, 120 g Myverol 18-04 in a plastic container and<br />

0.4790 g microencapsulated vitamin A in a wide mouthed opaque container with cover.<br />

(Note: An analytical balance is recommended for use in the weighing <strong>of</strong> the fortificant. Weighing <strong>of</strong><br />

the fortificant should be made as fast as possible to prevent the exposure <strong>of</strong> the fortificant to<br />

light and atmospheric oxygen. A wide mouth opaque container preferably <strong>of</strong> aluminum<br />

material is recommended for containing the vitamin A fortificant. Calibration <strong>of</strong> weighing<br />

scales/balances and temperature measuring devices are likewise recommended at least once<br />

a year to ensure the accurate measurement <strong>of</strong> weights and temperature.)<br />

3. Measure the temperature <strong>of</strong> the peanut butter and check if product temperature falls between 43 o C <<br />

70 o C. If temperature <strong>of</strong> peanut butter is greater than 70 o C, cool the product by manual mixing. If<br />

temperature <strong>of</strong> peanut butter is less than 43 o C, allow the peanut butter to pass through the grinder to<br />

increase product temperature.<br />

4. Add the vitamin A fortificant to the stabilizer and mix in circular strokes using a small rubber spatula<br />

for about 10 seconds.<br />

5. Slowly pour the mixture <strong>of</strong> fortificant and stabilizer into the peanut butter matrix while the peanut<br />

butter is being mixed manually. Continue mixing the product for two (2) minutes using circular<br />

strokes using a big stainless steel ladle or a plastic spatula.<br />

.<br />

6. When the required mixing time is reached, immediately fill the stabilized product in glass jars. Slowly<br />

tap the filled bottles to remove any entrapped air during the filling step then cover the bottle.<br />

(Note: <strong>The</strong> fortified stabilized product should be filled as fast as possible as the product will start to<br />

set causing difficulty in filling the product in the glass jars).<br />

7. Immediately place the filled bottles in an ice water bath maintained at 10 o C leaving it undisturbed for<br />

two (2) hours. Check the temperature <strong>of</strong> the ice water bath from time to time to ensure that the<br />

required temperature <strong>of</strong> 10 o C is maintained during the entire cooling period.<br />

(Note: During the cooling step, it is recommended that ice packs in plastic bags instead <strong>of</strong> ice cubes<br />

are used for the ice water bath. Unnecessary movements <strong>of</strong> the filled bottles in the ice water<br />

bath should be avoided so as not to disrupt the formation <strong>of</strong> crystals. Additional ice may be<br />

added to the water bath when temperature increases however care should be taken to prevent<br />

unnecessary movements to the filled bottles).<br />

8. After the required cooling time, the product is transferred to a cold storage area and stored in upright<br />

position, for conditioning/tempering<br />

140

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!