23.04.2013 Views

ResidenCiat System - Про Терм

ResidenCiat System - Про Терм

ResidenCiat System - Про Терм

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ResidenCiat</strong> <strong>System</strong><br />

The high comfort solution<br />

for the collectiv residential housing..<br />

A centralized production<br />

for each building or group of building.<br />

A user's terminal for each room<br />

silent and simple controller.<br />

Ciat, leader on the terminal units market, launches its new<br />

residential offer: RESIDENCIAT system. RESIDENCIAT<br />

<strong>System</strong> has been specially elaborated for heating and airconditioning<br />

of apartments and small tertiary. Its algorithms of<br />

regulation, developed in partnership with SIEMENS, meet perfectly<br />

the particular requirements of these installations.<br />

Designed for 2-pipe, 2-pipe + 2-wire and 4-pipe system, operating<br />

with recycled air, the RESIDENCIAT system consist of:<br />

● a ductable terminal unit of the Ciat range equipped with a<br />

multi- zones PI regulator.<br />

● wall terminals with display (1 Main terminal and up to 5<br />

zones terminals)<br />

A ductable Terminal Unit<br />

for each apartment<br />

(Major2 NCH, UTA...).<br />

And comfort throughout the year...<br />

● motorized dampers, factory mounted and wired<br />

● a discharge/return air circulation system (diffusion grille<br />

ensuring the COANDA effect).<br />

Thanks to its centralized control, RESIDENCIAT controls up to<br />

6 rooms (zones), ensuring a high level of thermal and acoustic<br />

comfort.<br />

The RESIDENCIAT system is proposed in regulation on<br />

water with 4-ways valves. The regulator controls actuator valve<br />

24 V with two rotation directions (3 points). This type of motor<br />

permits stabilising valve opening from 0 to 100% according to<br />

control requirements. Its operation is not influenced by the<br />

temperature of fluids circulating in the valve.<br />

A I R C O N D I T I O N I N G - R E F R I G E R A T I O N - A I R H A N D L I N G - H E A T E X C H A N G E - NN AA 00 44 .. 55 11 55 AA<br />

RESIDENCIAT<br />

1


2<br />

Operation<br />

<strong>ResidenCiat</strong> <strong>System</strong><br />

BEEDROOM 3<br />

LIVING ROOM<br />

From the main controller, the user adjusts the setpoints COMFORT and ECONOMY as well as the clock programming (*) ensuring<br />

ECO/COMFORT change-over for each zone.<br />

All controllers (main terminal and zone terminal) manage the ambient temperature of each respective zone as a function of settings<br />

transmitted by the main controller. The user can adjust the temperature of its zone from each terminal, and go against the<br />

ECONOMY and COMFORT modes resulting from the clock programming.<br />

The controller mounted on the unit communicates with the main controller and the zone controller. It summarizes the requirements<br />

and pilots all organs at his disposal : action on 3 ventilation speeds, valve(s), motorized dampers and the possible electric heater<br />

(electric heater piloting in chrono-proportional signal).<br />

The ventilation mode alone permits to transfer cold or hot from one room to the other without hot or chilled water consumption (closed<br />

valves: energy saving).<br />

The control parameters (neutral zone ventilation, proportional band, integration time) are factory pre - settled<br />

These parameters as well as the settings can be modified on site via the main controller (factory settings : hot 20°C, cold 24°C,<br />

dead zone 4K).<br />

A self-supplied communication bus ensures the connection between the regulator and each terminal (no separate bus supply).<br />

Necessary installation:<br />

BATHROOM<br />

KITCHEN<br />

BEEDROOM 1<br />

BEEDROOM 2<br />

For all application, RESIDENCIAT requires upstream:<br />

● a hot and/or cold water production (heat pump, CIAT chiller + boiler, other)<br />

● a 2 pipe or 4 pipe system distribution in the common parts<br />

● one energy counting system for each apartment<br />

In order to optimize the energy consumptions, it is possible to add a Cristopia storage system for calories.<br />

The RESIDENCIAT prices will result from the terminal unit selected and the number of zones to be controlled. Do not hesitate<br />

to consult us for further information.<br />

(*) Clock programming can be planified for one week.<br />

A I R C O N D I T I O N I N G - R E F R I G E R A T I O N - A I R H A N D L I N G - H E A T E X C H A N G E - NN AA 00 44 .. 55 11 55 AA<br />

WC

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!