SmartPower TM - Gallagher.eu
SmartPower TM - Gallagher.eu
SmartPower TM - Gallagher.eu
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
+ -<br />
Step 2: Connect to earth (ground) system<br />
Using Underground Cable remove 5cm (2”) of plastic coating from one end of the cable and connect to<br />
the green ( ) terminal on the Energizer. Attach the cable to the earth system by removing 10cm (4”) of insulation<br />
from the cable at each Earth Stake, then clamp the exposed wire to each stake using an Earth Clamp.<br />
Tighten the clamp.<br />
For further instructions on the earth (ground) system see the <strong>Gallagher</strong> Power Fence Manual enclosed.<br />
Reference Earth:<br />
An additional earth stake is required to allow correct measurement of the Earth Voltage. Install a single stake<br />
at least 60cm (2ft) long, at least 5m (16ft) from the main Energizer earth system and at<br />
least 10m (33ft) from any power supply earth peg, underground telephone or power cable.<br />
Using Underground Cable connect the Reference Earth Stake to the black ( )<br />
terminal on the Energizer.<br />
IMPORTANT!<br />
If the Reference Earth is not connected, the Earth Voltage display will flash 0.0. Note<br />
that if your earth is near perfect, the display may also flash 0.0. To confirm that your<br />
earth system is good check the voltage at the stakes is 0.0.<br />
Step 3: Connect the fence<br />
Connect Energizer’s red Output ( ) terminal to the fence using Underground Cable.<br />
Attach the other end of the cable to the fence using a Joint Clamp.<br />
For instructions on fence installation see the <strong>Gallagher</strong> Power Fence Manual enclosed.<br />
IMPORTANT!<br />
If you wish to use the Fence Voltage information see the section “Understanding your <strong>SmartPower</strong> Energizer:<br />
Fence Voltage and Alarm”, page 6.<br />
Step 4: Turn the Energizer on<br />
a) Plug the Energizer into a power outlet and switch ON.<br />
b) Allow at least 15 pulses for the Energizer to adapt to the fence system.<br />
IMPORTANT!<br />
Readings will change as your <strong>SmartPower</strong> Energizer responds to fence conditions. This is the Energizer<br />
monitoring the fence and adapting its power output accordingly. Read the sections “Understanding your<br />
<strong>SmartPower</strong> Energizer” pages 5-7 for a complete understanding of the displays and alarms.<br />
We recommend the earth system is tested after installation as per the “Earth Test” in the “Earth Voltage and<br />
Alarm” section page 7.<br />
Installation Error:<br />
If the Output and Earth terminals have been connected the wrong way around the Energizer will display the<br />
reading E7. If this occurs re-connect the terminals correctly.<br />
!<br />
Keep the Quick Reference Help Guide beside your Energizer.<br />
For Mains Operation with Battery Back-up and for Battery Only Operation:<br />
IMPORTANT!<br />
To connect the battery, you will need to use the <strong>Gallagher</strong> MBX Battery Lead (G5740, not included). Plug the<br />
battery leads into the back of the Energizer before mounting the Energizer. The red lead must be next to the (+)<br />
symbol and the black lead next to the (-) symbol on the back of the Energizer.<br />
Important<br />
It is very important to have a high quality earth system. For<br />
an all live wire fence system save time by installing at least<br />
9 Earth Stakes before you start.<br />
Poor earthing is the most common reason for poor electric<br />
fence performance. To make life easy, <strong>SmartPower</strong><br />
displays your Earth Voltage. Keep adding Earth Stakes<br />
until earth voltage is 0.2kV or less.<br />
Find a location for your earth system that is permanently<br />
damp, has high fertility or salinity and is away from dairy<br />
sheds. Install the earth system at least 10m (33ft) from<br />
any power supply earth peg, underground telephone or<br />
power cable. The best construction is 2m (6ft) long<br />
galvanised stakes or Super Earth Kits,<br />
3m (10ft) apart, connected to the Energizer by a single<br />
high quality wire (Underground Cable). Do not use<br />
materials that rust. Use Super Conductive Aluminium<br />
Cable if the earth system is over 100m (300ft)<br />
from the Energizer.<br />
RED<br />
To Fence<br />
GREEN<br />
4<br />
BLUE<br />
To Section of Fence<br />
BLACK<br />
To Earth System To Reference Earth