Figure 6‐23 displays <strong>the</strong> global statistics for <strong>the</strong> HYSPLIT sensitivity tests with Figures 6‐23a <strong>and</strong><br />

6‐23b containing <strong>the</strong> statistical metrics where <strong>the</strong> best performing model has <strong>the</strong>, respectively,<br />

lowest <strong>and</strong> highest score. For <strong>the</strong> FOEX metrics, <strong>the</strong> INITD3 scores <strong>the</strong> best with a 3.4% FOEX<br />

score followed by INITD4 (‐7%), INITD104 (‐8.6%), <strong>and</strong> finally INITD103 (‐9.5%). INITD2 scored<br />

worst with a ‐28.9%. INITD0, 1, 130, <strong>and</strong> 140 performed nearly as poorly with scores ranging<br />

between ‐21.9% to ‐24%. Using <strong>the</strong> NMSE statistical performance metric, <strong>the</strong> best performing<br />

configuration was INITD130, 140, <strong>and</strong> 3 with values <strong>of</strong> 17, 18, 19 pg m ‐3 respectively. The<br />

model configurations with <strong>the</strong> highest predicted error were INITD1 <strong>and</strong> INITD2 with values <strong>of</strong><br />

approximately 325 <strong>and</strong> 333 pg m ‐3 . For <strong>the</strong> KS parameter, <strong>the</strong> four puff‐particle model<br />

configuration options (INITD3,4,103,104) again showed <strong>the</strong> best scores.<br />

For <strong>the</strong> within a factor <strong>of</strong> 2 <strong>and</strong> 5 metric (FA2 <strong>and</strong> FA5, Figure 6‐23b, top), <strong>the</strong> hybrid puff‐<br />

particle configurations INITD3 <strong>and</strong> INITD4 <strong>and</strong> <strong>the</strong>ir counterpart particle‐puff configurations<br />

INITD103 <strong>and</strong> INITD104 are clearly performing better than pure particle (INITD0) or puff<br />

(INITD1 <strong>and</strong> INITD2) configurations. For <strong>the</strong> PCC metric, INITD140 had <strong>the</strong> highest (0.69)<br />

followed by INITD104 (0.64) <strong>and</strong> INITD0 <strong>and</strong> 103 (0.63). Interestingly, it appears that <strong>the</strong> higher<br />

PCC score for INITD103 is <strong>the</strong> main reason for <strong>the</strong> highest overall model RANK as both INITD3<br />

<strong>and</strong> 103 had nearly identical spatial performance while INITD3 had slightly better KS scores.<br />