VELO (Internal velocity preset)<br />

W.E.ST. Elektronik GmbH<br />

Commands Parameter Defaults Units Description<br />

velo x x= 1000… 10000 10000 0,01%<br />

Here the maximum velocity can be limited internally. The limitation function corresponds to the external<br />

velocity preset if VS was parameterized with EXT.<br />

VS (internal or external velocity preset)<br />

Commands Parameter Defaults Units<br />

vs x x= EXT|INT INT<br />

Switch over between internal and external velocity preset.<br />

In case of external velocity preset external voltages at PIN 9 and PIN 10 are used. An input of 10V corresponds<br />

with 100% speed.<br />

VRAMP (ramp time for the external velocity)<br />

Commands Parameter Defaults Units<br />

vramp x x= 1… 2000 50 ms<br />

Here the ramp time for velocity changes will be set.<br />

Operating shocks can be reduced when changing the external velocity.<br />

VMODE (Activation of the NC mode)<br />

Commands Parameter Defaults Units<br />

vmode x x= ON|OFF OFF<br />

With this parameter the NC mode (almost closed loop controlled velocity) will be activated. In OFF state<br />

the stroke depended deceleration is active; the velocity preset limits the output signal.<br />

In ON state the positioning demand value is generated by a profile generator and the axis drives to the<br />

target position with the defined velocity. The stroke time is defined by the parameter th.<br />