General installation remarks<br />

Explanation of terms and notes on safety<br />

Terms:<br />

W.E.<strong>ST</strong>. <strong>Elektronik</strong> <strong>GmbH</strong><br />

w: command signal<br />

c: internal signal<br />

u: internal signal<br />

ia, ib: output current (not scaled, only for information)<br />

Mounting instructions<br />

This module is for the installation provided in shielded electromagnetic compatibility housing (EMC conform).<br />

All cables operating outside have to be screened. A complete shielding is presupposed. It is also presupposed,<br />

that no strong electrical disturbances near the module are installed.<br />

Typical mounting area: 24V control signal area (near PLC)<br />

By the arrangement of the electrical cabinet a separation between power part (and power cables) and<br />

signal part must be taken in consideration. Experience shows us that the area next to the PLC (24 V<br />

area) is suitable. All digital and analogue inputs and outputs have filters and an over voltage protection. In<br />

case of correct wiring and shielding all EMC demands are fulfilled. If there are nevertheless any problems,<br />

please send us detailed sketches of mounting and wiring. We will look after this problem immediately.<br />

Even if all EMC-norms are fulfilled, technical problems in special cases are possible. Our experience has<br />

shown us that most of these problems are caused in the physical conditions of the cables. If everything is<br />

shielded continuously and configured correctly, no problems have to be expected.<br />

ATTENTION!<br />

ATTENTION!<br />

Due to electrical disturbances, failure at components as well as software faults can cause<br />

in individual cases uncontrolled movements at the drive. Appropriate safety precautions<br />

have to be considered during the engineering.<br />

Connection and start up of the module may only be allowed by qualified<br />

persons who have, because of education, experience and instruction, sufficient<br />

acknowledge on relevant directives and approved technical rules.<br />

Please read and follow the operating instructions carefully. In case of non<br />

observance of the instruction the guaranty and liability claim expires.<br />