MIN (compensation of the dead zone)<br />
MAX (maximum output signal)<br />
TRIGGER (threshold value of MIN)<br />
W.E.<strong>ST</strong>. <strong>Elektronik</strong> <strong>GmbH</strong><br />
Command Parameter Default Unit<br />
min:i x<br />
max:i x<br />
trigger x<br />
i= A|B<br />
x= 0… 5000<br />
x= 300… 10000<br />
x= 0… 2000<br />
-<br />
0<br />
10000<br />
200<br />
-<br />
0,01% / mA<br />
0,01% / mA<br />
0,01%<br />
With this command, the output signal is adjusted to the valve characteristics.<br />
MIN:B<br />
MAX:B<br />
ATTENTION: If the MIN value is set too high, it influences the minimal velocity, which<br />
cannot be adjusted any longer. In extreme case this causes to an oscillating around the<br />
closed loop controlled position.<br />
Output<br />
TRIGGER<br />
standard deadband<br />
compensation<br />
MAX:A<br />
MIN:A<br />
Seite 18 von 22 12.03.2008<br />
Input