14.04.2013 Views

Technical documentation - W.E.ST. Elektronik GmbH

Technical documentation - W.E.ST. Elektronik GmbH

Technical documentation - W.E.ST. Elektronik GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Parameter description<br />

S (setpoint parameterization)<br />

W.E.<strong>ST</strong>. <strong>Elektronik</strong> <strong>GmbH</strong><br />

Command Parameter Default Unit<br />

s:i x i= 0… 7<br />

x= -10000… 10000<br />

- 0,01%<br />

Depending on the external switching inputs S1, S2 and S4 the programmed values are retrieved.<br />

S1 = Pin 6, S2 = Pin 9 and S4 = Pin14.<br />

preset value -> 0 1 2 3 4 5 6 7<br />

Input S1 0 1 0 1 0 1 0 1<br />

Input S2 0 0 1 1 0 0 1 1<br />

Input S4 0 0 0 0 1 1 1 1<br />

RMODE (ramp mode)<br />

Command Parameter Default Unit<br />

rmode x x= SD|4Q SD -<br />

Selection:<br />

With “SD”: separate ramp for each setpoint.<br />

With “4Q”: general four quadrant ramps. (RA:1 x, RA:2 x, RA:3 x und RA:4 x).<br />

RA (ramptime parameterization)<br />

Commands Parameter Defaults Units<br />

ra:i x I= 0… 7<br />

x= 0..600000<br />

In mode „4Q“ ramp times 1… 4 are activated:<br />

RA: 1 up ramp solenoid A,<br />

RA: 2 down ramp solenoid A,<br />

RA: 3 up ramp solenoid B,<br />

RA: 4 down ramp solenoid B.<br />

See also command „RMODE“.<br />

100 ms<br />

Seite 15 von 22 12.03.2008