Technical documentation - W.E.ST. Elektronik GmbH
Technical documentation - W.E.ST. Elektronik GmbH
Technical documentation - W.E.ST. Elektronik GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Parameter description<br />
S (setpoint parameterization)<br />
W.E.<strong>ST</strong>. <strong>Elektronik</strong> <strong>GmbH</strong><br />
Command Parameter Default Unit<br />
s:i x i= 0… 7<br />
x= -10000… 10000<br />
- 0,01%<br />
Depending on the external switching inputs S1, S2 and S4 the programmed values are retrieved.<br />
S1 = Pin 6, S2 = Pin 9 and S4 = Pin14.<br />
preset value -> 0 1 2 3 4 5 6 7<br />
Input S1 0 1 0 1 0 1 0 1<br />
Input S2 0 0 1 1 0 0 1 1<br />
Input S4 0 0 0 0 1 1 1 1<br />
RMODE (ramp mode)<br />
Command Parameter Default Unit<br />
rmode x x= SD|4Q SD -<br />
Selection:<br />
With “SD”: separate ramp for each setpoint.<br />
With “4Q”: general four quadrant ramps. (RA:1 x, RA:2 x, RA:3 x und RA:4 x).<br />
RA (ramptime parameterization)<br />
Commands Parameter Defaults Units<br />
ra:i x I= 0… 7<br />
x= 0..600000<br />
In mode „4Q“ ramp times 1… 4 are activated:<br />
RA: 1 up ramp solenoid A,<br />
RA: 2 down ramp solenoid A,<br />
RA: 3 up ramp solenoid B,<br />
RA: 4 down ramp solenoid B.<br />
See also command „RMODE“.<br />
100 ms<br />
Seite 15 von 22 12.03.2008