W.E.<strong>ST</strong>. <strong>Elektronik</strong> <strong>GmbH</strong><br />
Analogue inputs<br />
The analogue inputs are designed for a maximum voltage range of 10 V. The voltage input is typically<br />
±10 V and the current input is 4… 20 mA with 12 mA for the center position of the directional valve.<br />
The inputs are protected with suppressor diodes (level 33 V) and RC-filter against transient overshoots.<br />
All analogue inputs must be screened.<br />
Differential input:<br />
Voltage level: unipolar 0… 10 V to PIN 9 / PIN 10 and 0…10 V to PIN 13 / PIN 14<br />
input resistance: 100 kΩ<br />
Current level: unipolar 4… 20 mA (PIN 9 to PIN 10 / PIN13 to PIN14)<br />
input resistance: app. 390 Ω<br />
Cable break down are monitored via the READY output and a flashing<br />
green LED.<br />
PWM outputs<br />
The output current is controlled via closed loop PWM current controller with PI characteristics. For high<br />
flexibility PWM frequency, dither frequency, dither amplitude and the PI compensator are free configurable.<br />
Cable break down and short cuts are monitored via the READY output and a flashing green READY<br />
LED.<br />
The outputs are protected with suppressor diodes (level 33 V) and RC-filter against transient overshoots.<br />
PWM:<br />
Output current: max. 2,6 A 1<br />
Frequency: 100… 7700 Hz<br />
Serial interface<br />
The serial interface is chosen for the parametering with a PC or a notebook. A suitable cable of 3,5mm<br />
JISC-6560 plug to 9pol. RS232 (PC compatible) can be bought under RS232-SO.<br />
You can parameterize our modules with each terminal program. However, by use of our application software<br />
WPC-300 you have enlarged functions and therefore it is preferable.<br />
Download: WWW.WE<strong>ST</strong>-ELECTRONICS.COM or WWW.W-E-<strong>ST</strong>.DE<br />
Features:<br />
• Table orientated parametering<br />
• Saving and loading of the parameter sets<br />
• Process data monitoring<br />
• Oscilloscope for dynamical optimization of the control parameters<br />
• Terminal window for flexible data input<br />
1<br />
The output current can be adjusted in % of the rated current or directly in mA. In case of mA adjustment, the “current”<br />
command should not be used.<br />
Seite 11 von 22 12.03.2008