W.E.<strong>ST</strong>. <strong>Elektronik</strong> <strong>GmbH</strong><br />

General IO description<br />

This description is a general description of the technical data of out open loop and closed loop control<br />

modules. Please check the implemented IO signals via the block diagram about availability.<br />

Power supply<br />

This module is designed for 10… 30 VDC (typical 12 V or 24 V) of a power supply. This power supply<br />

must correspond to the actual EMC standards.<br />

All inductivities at the same power supply (relays, valves …) must be provided with an over voltage protection<br />

(varistors, free-wheel diodes …).<br />

It is recommended to use a regulated power supply (linear or switching mode) for the supply of the module<br />

and the sensors. These power supplies have a clearly lower internal resistance in comparison with<br />

non regulated power supplies and therefore a better spurious rejection.<br />

Power supply : 10… 30 VDC, incl. ripple<br />

Power consumption: 100 mA + solenoid current consumption<br />

External protection: 5 A fast<br />

ATTENTION: Without an external fuse and in case of a continual short-circuit the<br />

module can be destroyed in spite of all internal protections.<br />

Digital inputs<br />

The digital inputs are designed for a voltage level of 12 V and 24 V. The typical connections to the PLC<br />

will not be screened if the modules are arranged carefully and with short cable lengths. As common potential<br />

0V (PIN 4) is used.<br />

All inputs are protected with suppressor diodes and RC-filters against transient overshoots.<br />

Low level: < 2 V<br />

High level: > 10 V<br />

Current: < 0,1 mA<br />

Digital outputs<br />

The digital outputs are designed for a voltage level of 12 V and 24 V. The typical connections to the PLC<br />

will not be screened if the modules are arranged carefully and with short cable lengths. As common potential<br />

0V (PIN 4) is used.<br />

All outputs are protected with suppressor diodes and RC-filters against transient overshoots.<br />

Low level: < 2 V<br />

High level: > 10 V<br />

Current: max. 50 mA (with load of 200 Ohm)<br />

Seite 10 von 22 12.03.2008