13.04.2013 Views

Digipass Plug-In for SBR Administrator Reference - Vasco

Digipass Plug-In for SBR Administrator Reference - Vasco

Digipass Plug-In for SBR Administrator Reference - Vasco

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Digipass</strong> <strong>Plug</strong>-<strong>In</strong> <strong>for</strong> <strong>SBR</strong> <strong>Administrator</strong> <strong>Reference</strong> Login Options<br />

Serial Number Separator<br />

If a Serial Number Separator is specified, the User may enter their <strong>Digipass</strong> serial<br />

number exactly as it appears on the back of their <strong>Digipass</strong> (or in the documentation<br />

provided to the User), including dashes. If a Serial Number Separator is not specified,<br />

the <strong>Digipass</strong> serial number must be padded to 10 characters, with all non-numerical<br />

characters removed.<br />

Back-End Authentication<br />

<strong>In</strong> the following login permutations tables, 'Back-End Authentication Required' means<br />

that the Back-End Auth. attribute is set to Always or If Needed.<br />

Note<br />

Back-End Authentication is required <strong>for</strong> Self-Assignment and Password<br />

Autolearn logins.<br />

10.1.1 Response Only – PAP<br />

Table 50: Login Permutations - Response Only PAP (1)<br />

Server PIN<br />

Required<br />

No Server<br />

PIN<br />

Required<br />

Login Type Existing PIN?<br />

Serial Number<br />

Separator?<br />

Normal login Yes N/A PIN+OTP<br />

Password Field Contents<br />

Stored Password Proxy On<br />

OR<br />

No Back-End Authentication 1<br />

Set PIN No N/A OTP+NewPIN+NewPIN<br />

Change PIN Yes N/A PIN+OTP+NewPIN+NewPIN<br />

Changed Password Yes N/A Password+PIN+OTP<br />

Set PIN and Changed Password No N/A Password+OTP+NewPIN+NewPIN<br />

Change PIN and Changed Password Yes N/A Password+PIN+OTP+NewPIN+NewPIN<br />

Self-Assignment 2<br />

Normal login N/A N/A OTP<br />

Yes Yes SerialNo+Sep.+Password+PIN+OTP<br />

No SerialNo+Password+PIN+OTP<br />

Changed Password N/A N/A Password+OTP<br />

No Yes SerialNo+Sep.+Password+OTP+NewPIN+NewPIN<br />

No SerialNo+Password+OTP+NewPIN+NewPIN<br />

Self-Assignment N/A Yes SerialNo+Sep.+Password+OTP<br />

No SerialNo+Password+OTP<br />

1 Back-End Authentication is required <strong>for</strong> Self-Assignment and Password Autolearn logins.<br />

2 If a Serial Number Separator is not set, the serial number must have all non-numerical characters removed and be<br />

padded to 10 characters with preceding zeroes.<br />