77 0700 00 - Page 2 - Tunstall GmbH
77 0700 00 - Page 2 - Tunstall GmbH 77 0700 00 - Page 2 - Tunstall GmbH
PrimusGlobal + system driver CUS 77 0720 04 Flamenconurse call system ManagementCenter PrimusGlobal+ module “Connect” example Order number Product name Notes 77 0720 04 PrimusGlobal+ system driver CUS General description The PrimusGlobal + software family effectively complements the Flamenco nurse call system. Special system drivers supplement the “Connect” module with additional interfaces and performance features. If there is no suitable system driver for a special ap‐ plication, a customer specific driver can be devel‐ oped. Depending on the real amount of work and after writing the specification sheet additionally to the basic costs further costs for implementing may incur. For this a detailed calculation is made after appro‐ val of the specification sheet and an appropriate offer is furnished. Tunstall GmbH, Orkotten 66, 48291 Telgte, Germany, www.tunstall.de Flamenco Data Sheet Date 08/2010 Specifications are subject to change without notice. 70
SystemOrganizer 77 0750 00 - Page 1 - General description The SystemOrganizer software is a planning and configuration tool for the Flamenco system. It pro‐ vides the user interface to the OSY-ControlCenter and enables the complete parameter setting for the call system. The handling and the subdivision follows Flamen‐ co's basic principle. The physical parameters are strictly separated from the organisational assign‐ ments. The access is password protected by 5 different user levels. Herewith is ensured, that each user group (planning office, care management...) can only make the settings, which are important for him/ her. Right from the planning stage the SystemOrgani‐ zer is used to enter the project structures of buil‐ dings, wards and rooms. All parameters can be mo‐ dified every time to adapt to the respective needs. By using the data from the beginning of the plan‐ ning over the whole life cycle of the system it will ne‐ ver be necessary to enter data twice. All data can be copied, saved and read out from an OSY-Con‐ trolCenter. Herewith it is ensured, that every time the valid data are used. System planning Construction of the basic structure of buildings, wards, rooms Plan view presentation Screen shot directly from the screen Import of existing graphics Choosing pre-set room types Free allocation of room numbers and designations Easy handling by drag-and-drop Guided planning process Printable survey of buildings, wards, rooms Operation Interactive and user guided handling 5 user levels, password protection 3 display levels (physical, electrical, organisational) Access to all system and project data, tree structure Run capable on every PC with system access, remote access possible Order number Product name Notes 77 0750 00 SystemOrganizer Necessary accessories, order separately: Software training: Successful completing the training is a mandatory condition “SystemOrganizer” for using the SystemOrganizer. Tunstall GmbH, Orkotten 66, 48291 Telgte, Germany, www.tunstall.de Flamenco Data Sheet Date 08/2010 Specifications are subject to change without notice. 71
- Page 29 and 30: Connection socket combi TVL, bedhea
- Page 31 and 32: Pear push switch 70 071X 0X Pear pu
- Page 33 and 34: 1 Channel radio receiver 70 0831 00
- Page 35 and 36: 1 Channel bracelet transmitter 70 0
- Page 37 and 38: Connection socket ComStation PC 74
- Page 39 and 40: Patient handset 74 0747 00 General
- Page 41 and 42: Hospital LCD TV 22”, professional
- Page 43 and 44: Hospital LCD TV 32”, professional
- Page 45 and 46: Direction lamp 77 0111 02 General d
- Page 47 and 48: Corridor display Alpha 16 77 01X0 0
- Page 49 and 50: Room lamp code blue/cardiac alarm,
- Page 51 and 52: Room lamp, 3 sections, with doorpla
- Page 53 and 54: Door entry speaker 77 0350 00 Gener
- Page 55 and 56: ComTerminal Flamenco 77 0510 00 - P
- Page 57 and 58: Room Terminal Flamenco 77 0520 00 -
- Page 59 and 60: Control Terminal Flamenco 77 0550 0
- Page 61 and 62: ComStation PC 77 0602 00 - Page 2 -
- Page 63 and 64: ComStation TEL 77 0603 00 - Page 2
- Page 65 and 66: ComStation CT Flamenco 77 0606 00 -
- Page 67 and 68: ManagementCenter PC 77 0610 00 - Pa
- Page 69 and 70: ManagementCenter PC Push buttons 77
- Page 71 and 72: PrimusGlobal + “ManagementCenter
- Page 73 and 74: PrimusGlobal + “ComStation PC ”
- Page 75 and 76: PrimusGlobal + “Call recording”
- Page 77 and 78: PrimusGlobal + system driver HL7 77
- Page 79: PrimusGlobal + system driver FMS 77
- Page 83 and 84: PrimusGlobal + “System set-up & c
- Page 85 and 86: OSYlink-Group Lamp 77 0802 00 Order
- Page 87 and 88: OSYlink-Announcement 77 0804 00 Ord
- Page 89 and 90: Control Terminal ConfigSet 77 0920
- Page 91 and 92: OSY-ControlCenter 77 2000 00 - Page
- Page 93 and 94: OSYnet-SafetyController 77 2100 00
- Page 95 and 96: Power supply unit UPS 60 77 3400 10
- Page 97 and 98: Battery set for UPS 60 77 3450 00 G
- Page 99 and 100: OSYnet-Gateway 77 4001 00 Order no.
- Page 101 and 102: Sound detector wall mounted Z 00 82
- Page 103 and 104: Order no. Product name 00 0222 88 P
- Page 105 and 106: Order no. Product name 17 5100 00 B
- Page 107 and 108: Order no. Product name 70 0807 00 C
- Page 109 and 110: Order no. Product name 70 0841 00 R
- Page 111 and 112: Order no. Product name 77 0180 10 R
- Page 113 and 114: Order no. Product name 77 0901 00 S
- Page 115: Order no. Product name 80 6047 00 L
PrimusGlobal + system driver CUS<br />
<strong>77</strong> 0720 04<br />
Flamenconurse<br />
call system<br />
ManagementCenter<br />
PrimusGlobal+<br />
module “Connect”<br />
example<br />
Order number Product name Notes<br />
<strong>77</strong> 0720 04 PrimusGlobal+ system driver CUS<br />
General description<br />
The PrimusGlobal + software family effectively<br />
complements the Flamenco nurse call system.<br />
Special system drivers supplement the “Connect”<br />
module with additional interfaces and performance<br />
features.<br />
If there is no suitable system driver for a special ap‐<br />
plication, a customer specific driver can be devel‐<br />
oped.<br />
Depending on the real amount of work and after<br />
writing the specification sheet additionally to the<br />
basic costs further costs for implementing may<br />
incur.<br />
For this a detailed calculation is made after appro‐<br />
val of the specification sheet and an appropriate<br />
offer is furnished.<br />
<strong>Tunstall</strong> <strong>GmbH</strong>, Orkotten 66, 48291 Telgte, Germany, www.tunstall.de Flamenco Data Sheet Date 08/2010 Specifications are subject to change without notice.<br />
70