52<br />

Dimensions are shown for reference<br />

purposes only.<br />

M <strong>Series</strong><br />

<strong>Pin</strong> <strong>and</strong> <strong>Socket</strong> <strong>Connectors</strong><br />

Posted <strong>Connectors</strong><br />

Posted connectors are<br />

furnished preloaded with<br />

Size 16, posted contacts<br />

(as shown on page 32) <strong>and</strong><br />

are specifically designed<br />

to be wired with h<strong>and</strong><br />

tools <strong>and</strong> semiautomatic<br />

machines. The cavity<br />

centerline spacing is too<br />

close to accommodate<br />

the heads <strong>and</strong> m<strong>and</strong>rels<br />

of fully automatic machines.<br />

Post configurations of the<br />

preloaded contacts are<br />

available for accepting<br />

TERMI-POINT Clip <strong>and</strong><br />

wrap-type terminations.<br />

Dimensions are in inches <strong>and</strong> millimeters<br />

unless otherwise specified.<br />

Values in brackets are metric equivalents.<br />

Posted connector housings<br />

are made of black phenolic<br />

or diallyl phthalate <strong>and</strong> are<br />

available in sizes ranging<br />

from 6 thru 104 positions.<br />

They will mate with correspondingly<br />

sized st<strong>and</strong>ard<br />

connector (except .200<br />

[5.08] grid) housings<br />

loaded with Size 16 crimptype<br />

contacts. It is not<br />

recommended to mate two<br />

posted connectors. Since<br />

the preloaded posted<br />

contacts are rigid in the<br />

housing, mating two posted<br />

connectors, particularly of<br />

the larger sizes, would be<br />

difficult.<br />

Specifications subject to change. Technical Support Center<br />

1-800-522-6752<br />

www.tycoelectronics.com<br />

Catalog 82003<br />

Revised 3-01<br />

Posted connectors can<br />

be substituted for st<strong>and</strong>ard<br />

connectors in the Connector/<br />

Hardware Selection Charts,<br />

pages 10 to 25.<br />

Tyco does not recommend the use<br />

of shields or strain relief clamps with<br />

posted connectors because of the<br />

potential of shorting.