APPWD Schedule of Rates for Road and Bridges - Arunachalpwd.org

APPWD Schedule of Rates for Road and Bridges - Arunachalpwd.org APPWD Schedule of Rates for Road and Bridges - Arunachalpwd.org

arunachalpwd.org
from arunachalpwd.org More from this publisher
11.04.2013 Views

Preamble: Chapter – 9 PIPE CULVERTS 1 Pipe culverts of sizes 1000 mm and 1200 mm dia in single row and double row which are generally used on roads, have been included. Providing and laying of pipe has been included in the rate analysis. Items of auxiliary works such as excavation, bedding, backfilling, concrete and masonry shall be analysed, as provided under the respective sections and paid for separately. 2 Analysis has been given separately for NP2 pipes for ease of adoption. 3 Cost of any river training and protection work like stone pitching, apron, curtain wall etc. may be analysed under the respective item included in Chapter 16. 4 The joining of pipes is proposed by collar joints. 5 Chain & pulley for lifting the pipes is considered part of overheads. 49 6 The thickness of first class bedding has been taken as 150 mm. The height of bedding has been taken as 1/10th of overall height of pipe in the analysis. This may be modified as per thickness indicated in the approved drawing.

Item No. 9.1 9.2 9.3 Descriptions CHAPTER-9 PIPE CULVERTS Summary of Rate Analysis PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) Laying Reinforced Cement Concrete Pipe NP2/prestrssed concrete pipe on first class bedding in single row . (Laying Reinforced cement concrete pipe NP2/prestrssed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 50 Unit Rate cum 3023.00 A 1000 mm dia metre 1082.00 B 1200 mm dia Laying Reinforced Cement Concrete Pipe NP 2 /prestrssed concrete pipe on first class bedding in double row . (Laying Reinforced cement concrete pipe NP2 /prestrssed concrete pipe for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) metre 1458.00 A 1000 mm dia metre 2279.00 B 1200 mm dia metre 3040.00

Item<br />

No.<br />

9.1<br />

9.2<br />

9.3<br />

Descriptions<br />

CHAPTER-9<br />

PIPE CULVERTS<br />

Summary <strong>of</strong> Rate Analysis<br />

PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone<br />

aggregate 40 mm nominal size mechanically mixed, placed in foundation <strong>and</strong><br />

compacted by vibration including curing <strong>for</strong> 14 days.)<br />

Laying Rein<strong>for</strong>ced Cement Concrete Pipe NP2/prestrssed concrete pipe on<br />

first class bedding in single row . (Laying Rein<strong>for</strong>ced cement concrete pipe<br />

NP2/prestrssed concrete pipe <strong>for</strong> culverts on first class bedding <strong>of</strong> granular<br />

material in single row including fixing collar with cement mortar 1:2 but<br />

excluding excavation, protection works, backfilling, concrete <strong>and</strong> masonry<br />

works in head walls <strong>and</strong> parapets . )<br />

50<br />

Unit Rate<br />

cum 3023.00<br />

A 1000 mm dia metre 1082.00<br />

B 1200 mm dia<br />

Laying Rein<strong>for</strong>ced Cement Concrete Pipe NP 2 /prestrssed concrete pipe on<br />

first class bedding in double row . (Laying Rein<strong>for</strong>ced cement concrete pipe<br />

NP2 /prestrssed concrete pipe <strong>for</strong> culverts on first class bedding <strong>of</strong> granular<br />

material in double row including fixing collar with cement mortar 1:2 but<br />

excluding excavation, protection works, backfilling, concrete <strong>and</strong> masonry<br />

works in head walls <strong>and</strong> parapets . )<br />

metre 1458.00<br />

A 1000 mm dia metre 2279.00<br />

B 1200 mm dia metre 3040.00