TRANSFORMERS TYPE TED<br />

<strong>Network</strong> <strong>Transformers</strong><br />

(0.4 to 160 kVA)<br />

PRODUCT LEAFLET<br />

1<br />

60 10602 - 09/06/2011


PRODUCTS PRESENTATION<br />

SINGLE PHASE TRANSFORMERS FOR SINGLE PHASE NETWORKS<br />

Concentric two-pole cable<br />

TED MMX<br />

400 and 630 VA<br />

TED MMX<br />

1 to 5 kVA<br />

TED MMX<br />

10 kVA<br />

NETWORK ACCESSORIES<br />

Two-pole boxes :<br />

Dead end box 1 A<br />

Junction 1 A / 1 D<br />

Derivation 1 A / 2 D<br />

Derivation 1 A / 3 D<br />

TED MMX<br />

16 to 50 kVA<br />

SINGLE-PHASE TRANSFORMERS FOR THREE-PHASE NETWORKS<br />

Single pole or three pole cables<br />

TED MTT<br />

2 to 10 kVA<br />

TED MTT<br />

16 to 50 kVA<br />

<strong>Network</strong> accessories<br />

three pole box 1 A / 1 D<br />

THREE PHASE TRANSFORMERS FOR THREE PHASE NETWORKS<br />

Single-pole or three-pole cables<br />

TED TTT 5 to 32 kVA<br />

TEH TTT 50 to 160 kVA<br />

2


NETWORK TRANSFORMERS<br />

Type TED 0.4 to 160 kVA<br />

« Lead through » connection<br />

CONTENTS<br />

Pages<br />

GENERAL PRESENTATION ............................................................................................4 - 5<br />

SINGLE-PHASE NETWORKS<br />

- Single-phase transformers for single-phase networks<br />

* TED MMX from 0,4 to 10 kVA.......................................................................6 - 7<br />

* TED MMX from 16 to 50 kVA........................................................................8 - 9<br />

- Accessories for a single-phase network.....................................................................10 - 11<br />

- Two-pole terminal - model X.....................................................................................12 - 13<br />

THREE-PHASE NETWORKS<br />

- Single-phase transformers for three-phase networks<br />

* TED MTT from 2 to 10 kVA.........................................................…………..14 - 15<br />

* TED MTT from 16 to 50 kVA.........................................................................16 - 17<br />

- Three-phase transformers for three-phase networks<br />

* TED TTT from 5 to 32 kVA............................................................………….18 - 19<br />

* TEH TTT from 50 to 160 kVA.........................................................................20 - 21<br />

- Three-pole terminal.....................................................................................................22 - 24<br />

- Accessories for three-phase networks………………………………………………..25<br />

INTERLOCKING...................................................................................................................26<br />

BLUE BIP...............................................................................................................................27<br />

3


ALL THE AVANTAGES OF EPOXY RESINS<br />

For single-phase (400 VA to 50 kVA)<br />

or three-phase (5 kVA to 32 kVA) unpluggable transformers<br />

The use of epoxy resin guarantees that the transformers have the following characteristics:<br />

Corrosion resistant, remain unaltered over time.<br />

Watertight and immersible.<br />

Insulated.<br />

Can be buried into purposely-designed pits.<br />

MODULOBLOCS: MAIN CHARACTERISTICS<br />

Watertight and immersible sets.<br />

Conform to NFC 52 410 standards.<br />

Dielectric : Oil<br />

Primary insulation voltage : 7.2 kV<br />

Secondary insulation voltage : 1.1 kV<br />

Reduced losses<br />

Protection degree : IP 68 - IK 10<br />

Working temperature : - 15°C + 40°C<br />

Specially designed to support the no load lamp stress & strain.<br />

Studied to allow to allow network continuity in case of a transformer fault.<br />

MV PLUG-IN CONNECTION:<br />

The MV plug-in terminal systems of the connection interface guarantee total operational flexibility:<br />

Easy to plug in and unplug<br />

Optimum reliability: reinfored by isolating liquid BIP in the terminal compartments regardless of type of cable<br />

used, <strong>Augier</strong>’s specially-designed plug-in terminal meets all your needs.<br />

A switch protection channel inside the transformer allows insulation of a section by simply plugging in.<br />

TED MMX<br />

Two-pole terminal<br />

For concentric<br />

Two-pole cables<br />

TED MTT<br />

Elbow bent<br />

three-pole terminal<br />

for twisted cables<br />

The transformer low voltage output is carried out with a 1.5 metre-long H 07 RNF cable or on pluggable terminals.<br />

4


DOUBLE «AUTO» PROTECTED TRANSFORMERS:<br />

The protection devices directly incorporated in the transformer guarantee :<br />

MV protection by easily accessible HRC fuses.<br />

Optional:<br />

Low Voltage protection by means of thero-magnetic circuit breakers allows protection against short circuiting,<br />

linked to thermal protection with of a probe incorperated in the windings which guarantees elimination of<br />

possible permanent faults.<br />

Protection by HRC fuses.<br />

Stick fuse on a<br />

TED MMX 5 kVA<br />

TED TRANSFORMERS: ADVANTAGES<br />

Stick fuse on a<br />

TED TTT 5 kVA<br />

Complete range of equipment, to enable absence of voltage tests (VAT) to be<br />

carried out to conform to recommended NFC 17-200 standards, available on<br />

request.<br />

Connection accessories are routinely delivered with each transformer.<br />

Voltage adjusting tap changers of + 5 and + 7.5 % are provided to transformers<br />

from 16 kVA and to the three- phase transformers of all power ratings.<br />

A phase selector allows an even load distribution among the 3 phases of the<br />

supply network.<br />

Four-pole circuit breaker<br />

on a TED TTT 10 kVA<br />

Plug-in, MV network epoxy resin accessories are also available. They enable cable isolation to be carried out,<br />

among other things.<br />

On request <strong>Augier</strong> technicians carry out on site technical<br />

assistance, in France and world wide. This assistance<br />

facilitates start up of the MV installations and guarantees<br />

tecnical training leading to full understanding of the<br />

technical features of the product and how it works.<br />

5


TYPE<br />

Single-phase transformer for single-phase networks.<br />

Cast in resin, corrosion resistant, water-tight, plug-in<br />

connection designed for directly buried installation.<br />

Protection degree : IP 68<br />

Primary voltage : 3200 V (1)<br />

Primary winding insulation level : 7,2 kV<br />

Secondary no-load voltage : 237 V (2)<br />

Secondary winding insulation level : 1,1 kV<br />

Coupling : single-phase<br />

Dielectric : oil<br />

Power rating : 400, 630, 1000, 2000, 3000,<br />

5000, 10000 VA<br />

Nominal power depending on public lighting standards<br />

320, 504, 800, 1600, 2400, 4000, 8000 VA<br />

<strong>Transformers</strong> comply with NFC 52 410 standards.<br />

CONDITIONS of USE:<br />

Environmental class AD7 : can be partly or completely<br />

immersed in water for a limited time period.<br />

MV INLET<br />

A -Two -pole plug-in concentric, universal terminals for<br />

3.6/6 kV concentric two -pole cable 2 x 6, 10, 16, or<br />

25 mm² cross-section conforming to NF C33-221 standards.<br />

B - «Lead-through» connection in transformer.<br />

TAP CHANGER FOR VOLTAGE ADJUSTMENT<br />

No adjustment.<br />

MV PROTECTION<br />

By means of HRC fuse, rupturing capacity 15 kVA.<br />

MV POTENTIAL CONDITION<br />

The winding is not connected to earth potential.<br />

On request: Earthed end of the winding connected to<br />

outer conductor (neutral) of the cable.<br />

(1) On request: other voltages compatible with primary winding<br />

insulation level.<br />

(2) On request: other voltages compatible with secondary<br />

winding insulation level.<br />

TED MMX - 0.4 to 10 kVA<br />

LV OUTLET<br />

Two-pole 6 metre-long H.07.RN.F cable<br />

< to 1 kVA : cross-section 2 x 2.5 mm²<br />

1 to 5 kVA : cross-section 2 x 6 mm²<br />

10 kVA : cross-section 2 x 10 mm²<br />

On request : two-pole plug-in terminal for H.07.RN.F.<br />

cable with maximum 2 x 25 mm² cross-section.<br />

LV PROTECTION<br />

Without LV protection<br />

On request:<br />

The cut-out device ensures direct magnetic protection<br />

and thermal protection by means of a probe incorporated<br />

in the windings; breaking capacity: 6 kA.<br />

*Single-pole + neutral, curve B, for the TED ≤ 6 kVA<br />

*Two-pole, curve B, for the TED > 6 kVA<br />

By HRC fuses.<br />

LV POTENTIAL CONDITION<br />

One end of the LV winding is connected to the earthing terminal<br />

(blue lead).<br />

On request: centre tap of the LV winding connected to the<br />

earthing terminal. In this case, possible LV protection must<br />

be two-pole.<br />

EARTHING TERMINAL<br />

By means of a M10 threaded rod, connected internally to<br />

magnetic circuit.<br />

DIELECTRIC TESTS<br />

Impulse withstands : 45 kV - Wave 1 / 50<br />

Power frequency withstands voltage : 16 kV - 50 Hz -<br />

1 minute.<br />

USER INFORMATION WRITTEN ON COVER<br />

Terminals assembly instructions:<br />

manuals available on request.<br />

EQUIPMENTS<br />

The transformers are delivered with :<br />

Two HV preparation leaflets.<br />

Two non-waterproof transport plugs.<br />

The BIP is delivered separately.<br />

Handling ropes.<br />

Technical leaflet for the assembly of the plug-in<br />

terminals.<br />

6


TED MMX 400, 630 VA<br />

TED MMX 10 kVA<br />

TED MMX 1 to 5 kVA<br />

TED MMX TECHNICAL DATA - 0.4 to 10 kVA<br />

1 - MV fuses<br />

2 - MV Input terminal<br />

3 - Output terminal<br />

4 - Rating plate<br />

5 - Earth terminal<br />

6 - LV protection (optional)<br />

7 - Two-pole LV output<br />

Power rating (kVA) 400 630 1000 2000 3000 5000 10000<br />

Power output (kVA) 320 504 800 1600 2400 4000 8000<br />

Iron losses (W) 10 15 20 30 45 60 110<br />

Copper losses (W) 13 20 26 38 45 75 130<br />

Short-circuit impedance (%) 3.4 3.4 2.9 2.5 2.5 2.5 3.0<br />

Voltage drop (%) cos φ = 1 3.2 3.17 2.6 1.91 1.52 1.52 1.34<br />

Voltage drop (%) cos φ = 0,8 3.16 3.28 2.84 2.49 2.4 2.4 2.66<br />

Magnetising current (%) 12 10 9 8.5 8 8 5<br />

Length (mm) 361 361 400 400 400 400 Ø500<br />

Width (mm) 256 256 374 374 374 374 Ø500<br />

Height (mm) 430 430 435 435 435 435 565<br />

Total weight (kg) 33 35 55 60 65 77 145<br />

Weight of oil filling (kg) 4 3.6 8 7.6 8 7.6 18.5<br />

7


TYPE<br />

Single-phase transformer for single-phase networks.<br />

Cast in resin, corrosion resistant, water-tight, plug-in<br />

connection designed for directly buried installation.<br />

Protection degree : IP 68<br />

Primary voltage : 3200 V (1)<br />

Primary winding insulation level : 7.2 kV<br />

Secondary no-load voltage : 237 V (2)<br />

Secondary winding insulation level : 1.1 kV<br />

Coupling : single phase<br />

Dielectric : oil<br />

Power rating : 16 - 25 - 32 - 50 kVA<br />

Nominal power depending on public lighting standards<br />

12.8 - 20 - 25.6 - 40 kVA<br />

<strong>Transformers</strong> comply with NFC 52 410 standards.<br />

OPERATING CONDITIONS<br />

Environmental condition AD7 : can be partly or<br />

completely immersed in water for a limited time period.<br />

MV INLET<br />

A- Two-pole plug-in concentric, universal terminals for<br />

3.6/6 kV concentric two-pole cable 2 x 6, 10, 16, or<br />

25 mm² cross-section according to NF C33-221 standards.<br />

B- «Lead-through» connection in transformer.<br />

TAP CHANGER FOR VOLTAGE ADJUSTMENT<br />

Adjustment by strips off voltage, taps + 5, + 7.5 % (3)<br />

MV PROTECTION<br />

By means of HRC fuse, rupturing capacity 50 kA.<br />

MV POTENTIAL CONDITION<br />

The winding is not connected to earth potential.<br />

On request: Earthed end of the windin connected to the<br />

outer conductor (neutral) of the cable.<br />

(1) On request: other voltages compatible with primary winding<br />

insulation level.<br />

(2) On request: other voltages compatible with secondary<br />

winding insulation level.<br />

(3) Other percentage values on request.<br />

TED MMX - 16, 25, 32, 50 kVA<br />

LV OUTLET<br />

Two-pole 6 metre-long H.07.RN.F cable , cross-section:<br />

16 kVA: 25 mm² for 230 V. Two single-pole 6 metre-long<br />

H.07.RNF cable, cross-section:<br />

25 kVA: 35 mm² for 230 V.<br />

32 kVA : 50 mm² for 230 V<br />

50 kVA : 95 mm² for 230 V.<br />

On request for the 16 kVA : two-pole plug-in<br />

terminal for H.07.RN.F. cable with a maximum<br />

cross-section of 2 x 25 mm².<br />

LV PROTECTION<br />

Without LV protection<br />

On request:<br />

The cut-out device ensures magnetic protection and<br />

thermal protection by means a probe incorporated in<br />

the winding (only for the 16 and 25 kVA)<br />

Breaking capacity: 16 kVA : 85 kA - 25 kVA : 85 kA<br />

Protection by means of one HRC fuse<br />

LV POTENTIAL CONDITION<br />

One end of the LV winding is connected to the earthing<br />

terminal (blue lead).<br />

On request: centre tap of the LV winding connected to<br />

the earthing terminal.<br />

EARTHING TERMINAL<br />

By means of a M10 threaded rod, connected internally to<br />

the transformer core.<br />

DIELECTRIC TESTS<br />

Impulse withstands: 45 kV - wave 1/ 50<br />

Power frequency withstands voltage:<br />

16 kV - 50 Hz - 1 minute<br />

USER INFORMATION WRITTEN ON<br />

THE COVER<br />

Terminals assembly instructions:<br />

Manual available on request.<br />

EQUIPMENTS<br />

The transformers are delivered with:<br />

Two MV plug-in terminals for assembly.<br />

Two non-waterproof blanking off taps.<br />

The BIP is delivered separately.<br />

Handling ropes.<br />

One technical leaflet for the assembly of the MV<br />

plug-in terminals.<br />

8


TED MMX 16 kVA TED MMX 25 kVA<br />

Input Output<br />

TED MMX 32 - 50 kVA<br />

Input Output<br />

Input Output<br />

1 - LV Protection (optional)<br />

2 - LV Output<br />

3 - MV adjustment switch<br />

4 - Two-pole unpluggable terminals<br />

5 - MV fuses<br />

TED MMX TECHNICAL DATA - 16, 25, 32, 50 kVA<br />

Power rating (kVA) 16 25 32 50<br />

Power output (kVA) 12.8 20 25.6 40<br />

Iron losses (W) 100 130 155 160<br />

Copper losses (W) 360 580 600 900<br />

Short-circuit impedance (%) 5.5 5 5 6.5<br />

Voltage drop (%) cos φ = 1 2.3 2.42 1.98 2.00<br />

Voltage drop (%) cos φ = 0,8 4.81 4.51 4.28 5.11<br />

Magnetising current (%) 6 5 3.1 2.3<br />

Length (mm) 658 784 925 925<br />

Width (mm) 540 574 652 650<br />

Height (mm) 620 720 830 830<br />

Total weight (kg) 250 375 530 650<br />

Weight of oil filling (kg) 35 75 100 110<br />

9


ACCESSORIES FOR SINGLE-PHASE NETWORKS<br />

DEAD END BOX, JUNCTION AND<br />

DEVIATION BOXES<br />

These different boxes made up of pluggable universal<br />

two-pole consentric terminals receive either a concentric<br />

two-pole 3.6 / 6 kV cable, or a radical field single pole<br />

3.6 / 6 kV cable made up of a twisted cable strut. A single<br />

pole cable’s cross section can be either 6, 10, 16, 25 or 35<br />

mm². External diameter of the watertight outer covering<br />

can’t exceed 24 mm.<br />

They are delivered with the necessary equipment needed<br />

to make the MV cable heads, as well as thewaterproof<br />

plug covers.<br />

1AX Box<br />

(dead end box)<br />

1AX / 1DX Box<br />

(junction box)<br />

JUNCTION AND DEVIATION BOXES WITH<br />

EARTHING OF THE PERIPHERAL CABLE<br />

On all these boxes it is possible to add an earthing<br />

terminal connected to the interior of the plug-in<br />

peripheral terminals. This addition does not change<br />

its dimensions.<br />

1AX / 2DX Box<br />

(T-deviation box)<br />

1AX / 3DX Box<br />

(Cross-type deviation box)<br />

Length Width Height Weight<br />

1AX 70 70 375 1.5 kg<br />

1AX / 1DX 150 70 375 3.3 kg<br />

1AX / 2DX 150 150 375 5.6 kg<br />

1AX / 3DX 150 150 375 7.4 kg<br />

10


LINE DEAD END SPARKS GAP<br />

<strong>Network</strong> in TNRS* diagram with a concentric two-pole cable<br />

The peripheral conductors (neutral) of the concentric two pole 3.5/6 kV cable are insulated to 1000 V level. In the<br />

event of using this cable with a TNRS distribution system, accidental damage to cable will result in a short circuit<br />

with the central conductor (3.5/6 kV); causing peripheral voltage to exceed the 1000 V limit to 3200 V. This can<br />

also be caused by the primary winding of the TED transformer.<br />

A line dead end spark gap results in a connection between the peripheral cable and the earth. An overvoltage limiter<br />

allows, in this case, a dangerous potential to pass the cable.<br />

This will activate the differential protection installed in the delivered substations public lighting switchboards, on<br />

the feeder concerned.<br />

The transformer is delivered with a 2 m strap of 25 mm² concentric two-pole cable equipped with a universal cable<br />

head, to be plugged into the terminal left unused of the last TED transformer of the line or of the deviation.<br />

It is imperative that the earth terminal be connected to the small earth cable.<br />

Brochures available on request.<br />

FRONT VIEW TOP VIEW<br />

MV NETWORK MAINTENANCE ACCESSORIES<br />

These accessories enable operations to be carried out following recommended safety rules, in particular to test for<br />

absence of voltage before intervention of TED transformer.<br />

* TNRS diagram applies to cases where the cable periphiral conductor is maintained isolated at level of network transformers.<br />

11


GENERAL INFORMATION<br />

TWO-POLE TERMINAL MODEL X<br />

This terminal consists of two parts :<br />

a- the plug is joined to the device and contains a central and periphical contact. It is designed to receive all plugs<br />

from 6 to 25mm².<br />

b- the plug is on the cable. The parts ensuring electric contacts must be adapted to cable cross-section.<br />

PROTECTION AGAINST WATER PENETRATION<br />

This is carried out in two stages :<br />

Between the sheath (3) and the envelope with the help of an o-ring seal (4). Toughness: 70° shore, +/- 5°.<br />

Between the cable and the sheath (3) with the help of a thermo-retractable sheath.<br />

NB: extra insulation is provided using an insulating liquid BIP inside the terminal compartment. This liquid acts as<br />

a density dielectric, thus allowing water to be kept on surface; otherwise this would get inside the terminal in the<br />

event of cable damage.<br />

IMPORTANT<br />

Essential infomation to be given on order:<br />

• Type and section of cable.<br />

• Provide sample of cable if it’s a special type.<br />

Example of protected cable<br />

Copper core<br />

Semi-conductor<br />

PR insulation<br />

Waterproof concentric<br />

conductor<br />

Redinsulation shaft<br />

Cable protection<br />

Redexterior shaft<br />

Cable cross<br />

section<br />

(mm²)<br />

RECOMMENDED CABLE<br />

Two-pole concentric cable 3,6 / 6 kV<br />

Maximum<br />

diameter on<br />

the insulation<br />

(mm)<br />

Approximate diameter<br />

on the exterior sleeve (mm)<br />

Non<br />

protected cable<br />

Acceptable<br />

current (A)<br />

Protected cable Buried<br />

6 + 6 16 18.6 19.6 63<br />

10 + 10 16.5 19.2 20.2 90<br />

16 + 16 18.3 21 22 115<br />

25 + 25 20.5 23.2 24.2 150<br />

Curved ribbon : 10 x diameter<br />

12


2<br />

1<br />

3<br />

4<br />

Accessories for the two-pole plug<br />

5<br />

6<br />

8<br />

7<br />

9<br />

Mounted<br />

two-pole plug<br />

Socket on the top<br />

of the TED MMX<br />

1- Screwing nut<br />

2- Thermo-retractable sleeve<br />

3- Sheath<br />

4- O-ring seal<br />

5- Peripheral nozzle<br />

6- Under the peripheral nozzle<br />

7- Central nozzle<br />

8- Spacer<br />

9- Nut<br />

Plugged-in and then<br />

waterproofed two-pole plug<br />

13


TYPE<br />

Single-phase transformer for three -phase networks. Cast<br />

in resin, corrosion resistant, water-tight, plug-in<br />

connection designed for directly buried installation.<br />

Protection degree : IP 68<br />

Primary voltage : 5500 V (1)<br />

Primary winding insulation level : 7.2 kV<br />

Secondary no-load voltage : 237 V (2)<br />

Secondary winding insulation level : 1.1 kV<br />

Coupling : single-phase<br />

Dielectric : oil<br />

Power rating : 2 - 3 - 5 - 10 kVA<br />

Nominal power depending on public lighting<br />

standards : 1.6 - 2.4 - 4 - 8 kVA<br />

<strong>Transformers</strong> comply with NFC 52410 standards.<br />

OPERATING CONDITIONS<br />

Environmental condition AD7: can be partly or completely<br />

immersed in water, for a limited time period.<br />

MV INLET<br />

a- Three-phase plug-in connection for three-phase cable,<br />

6 kV, belt or radial field type (see description 60 10472)<br />

Maximum current: 80 A<br />

Maximum overall diameter of cable: 44,5 mm, maximum<br />

allowance included.<br />

b- «Lead-through» connection in transformer.<br />

TAP CHANGER FOR VOLTAGE ADJUSTMENT<br />

No voltage adjustment provided.<br />

MV PROTECTION<br />

By means of two HRC fuses, rupturing capacity 10 kA.<br />

PHASE SELECTOR<br />

Medium Voltage fuses allows even load distribution<br />

among the three- phases of supply network.<br />

(1) On request : other voltages compatible to the primary<br />

winding insulation level.<br />

(2) On request : other voltages compatible to the secondary<br />

winding insulation level.<br />

TED MTT - 2, 3, 5, 10 kVA<br />

LV OUTLET<br />

Two-pole 6 m. H.07 cable :<br />

2 to 5 kVA: cross-section 6 mm²<br />

10 kVA: cross-section 10 mm²<br />

On request: Two-pole plug-in terminal for H.07.RN.F<br />

cable with maximum cross-section 25 mm².<br />

LV PROTECTION<br />

Without Low Voltage protection<br />

On request:<br />

The cut-out device ensures direct magnetic and thermal<br />

protection by means of a probe incorporated in the<br />

windings, breaking capacity: 6 kA<br />

*single-pole + neutral, curve B, for TED ≤ 6 kVA:<br />

*two-pole, curve B for TED > 6 kVA<br />

By HRC fuses.<br />

LV ELECTRICAL POSITION<br />

The end of the LV winding is linked to earthing terminal<br />

(blue conductor).<br />

On request: Centre tap of LV winding connected to the<br />

earthing terminal. In this case, possible LV protection<br />

must be two-pole.<br />

EARTHING TERMINAL<br />

By means of a M10 threaded rod, connected internally to<br />

magnetic circuit.<br />

DIELECTRIC TESTS<br />

Impulse withstand: 60 kV - Wave shape 1 / 50<br />

Power frequency<br />

withstand voltage: 22 kV - 50 Hz -1 minute<br />

USER INFORMATION WRITTEN ON COVER<br />

MV cable terminal assembly instructions : manual<br />

available on request for different cable types.<br />

EQUIPMENTS<br />

<strong>Transformers</strong> are delivered with:<br />

Two MV plug-in terminals for assembly.<br />

Two non-waterproof transport only taps.<br />

BIP delivered separately.<br />

Handling ropes.<br />

One technical leaflet for assembling MV plug-in<br />

terminals.<br />

14


TED MTT 2 to 10 kVA<br />

1- MV fuses and phase-selector<br />

2- MV three-pole terminal<br />

3- MV inlet<br />

4- MV outlet<br />

5- Rating plate<br />

6- Earthing terminal M 10 x 20<br />

7- LV protection (optional)<br />

8- LV output<br />

TED MTT TECHNICAL DATA - 2, 3, 5, 10 kVA<br />

Power rating (kVA) 2 3 5 10<br />

Power output (kVA) 1.6 2.4 4 8<br />

Iron losses (W) 30 45 60 110<br />

Copper losses (W) 38 45 75 130<br />

Short-circuit impedance (%) 2.5 2.5 2.5 3<br />

Voltage drop (%) cos φ = 1 1.91 1.52 1.52 1.34<br />

Voltage drop (%) cos φ = 0,8 2.49 2.4 2.4 2.66<br />

Magnetising current (%) 8.5 8 8 5<br />

Diameter (mm) Ø500 Ø500 Ø500 Ø500<br />

Height (mm) 485 485 485 485<br />

Total weight (kg) 100 110 115 170<br />

Weight of oil filling (kg) 20 18 14 23<br />

15


TED MTT - 16, 25, 32, 50 kVA<br />

TYPE<br />

Single-phase transformer for three-phase networks. Cast in<br />

resin, corrosion resistant, water-tight, plug-in<br />

connection designed for directly buried installation.<br />

Protection degree : IP 68<br />

Primary voltage : 5500 V (1)<br />

Primary winding insulation level : 7.2 kV<br />

Secondary no-load voltage : 237 V (2)<br />

Secondary winding insulation level : 1.1 kV<br />

Coupling : single phase<br />

Delectric : oil<br />

Power rating : 16 - 25 - 32 - 50 kVA<br />

Nominal power depending on public<br />

lighting standards : 12.8 - 20 - 25.6 - 40 kVA<br />

<strong>Transformers</strong> comply with NFC 52410 standards.<br />

OPERATING CONDITIONS<br />

Environmental condition AD7: can be partly or completely<br />

immersed in water for a limited time period.<br />

MV INLET<br />

a- Three-phase plug-in connection for three-phase cable, 6<br />

kV, belt or radial field type (see leaflet 60 10472)<br />

Maximum current : 80 A<br />

Maximum overall cable diametre : 44.5 mm, maximum<br />

allowance included.<br />

On request : elbow bent terminals.<br />

b- «Lead-through» connection in transformer.<br />

TAP CHANGER FOR VOLTAGE ADJUSTMENT<br />

Adjustment by strips off voltage, taps + 5, + 7,5 % (3)<br />

MV PROTECTION<br />

By means of two HRC fuses, rupturing capacity 15 kA.<br />

PHASE SELECTOR<br />

By means of a switching device, allowing even load<br />

distribution among the three phases of supply network.<br />

(1) On request : other voltages compatible with primary winding<br />

insulation level.<br />

(2) On request : other voltages compatible with secondary<br />

winding insulation level.<br />

(3) Other percentage values on request.<br />

LV OUTLET<br />

Two-pole 6 meter-long H.07.RN.F cable<br />

16 kVA : cross-section 25 mm²<br />

Two single-pole 6 meter-long H.07.RN.F cable<br />

25 kVA : cross-section 50 mm²<br />

32 kVA : cross-section 50 mm²<br />

50 kVA : cross-section 95 mm²<br />

On request for the 16 kVA : two-pole plug-in terminal<br />

for H.07.RN.F cable with 25 mm² maximum cross-section.<br />

LV PROTECTION<br />

Without low voltage protection. On request, the cut-out<br />

device ensures direct magnetic protection and thermal<br />

protection by means of a probe incorporated in the<br />

windings (only for the 16 and 25 kVA).<br />

Breaking capacity : 16 kVA : 85 kA - 25 kVA : 85 kA<br />

Protection by HRC fuses.<br />

LV POTENTIAL CONDITION<br />

One end of the LV winding is connected to the earthing<br />

terminal (blue lead).<br />

On request: Centre tap of the LV winding connected to<br />

earthing terminal.<br />

EARTHING TERMINAL<br />

By means of a M10 threaded rod, connected internally to<br />

magnetic circuit.<br />

DIELECTRIC TESTS<br />

Impulse withstand : 60 kV - Wave 1 / 50<br />

Power frequency withstand voltage : 22 kV - 50 Hz -<br />

1 minute.<br />

USE INFORMATION WRITTEN ON COVER<br />

MV cable terminal assembly instructions :<br />

manual available on request for different cable types.<br />

EQUIPMENTS<br />

The transformers are delivered with:<br />

Two MV plug-in terminals for assembly.<br />

Two non-waterproof blanking off taps.<br />

BIP is delivered separately.<br />

Handling ropes.<br />

One technical leaflet for assembling MV plug-in<br />

terminals.<br />

16


Input<br />

TED MTT 16, 25 kVA<br />

Output<br />

1 - LV output<br />

2 - LV protection (optional)<br />

3 - MV Phase selector<br />

4 - MV adjusting switch<br />

5 - MV three- pole unpluggable terminals<br />

6 - MV fuses<br />

Input<br />

TED MTT TECHNICAL DATA - 16, 25, 32, 50 kVA<br />

TED MTT 32, 50 kVA<br />

Output<br />

Power rating (kVA) 16 25 32 50<br />

Power output (kVA) 12.8 20 25.6 40<br />

Iron losses (W) 100 130 155 160<br />

Copper losses (W) 360 580 600 900<br />

Short-circuit impedance (%) 5.5 5 5 6.5<br />

Voltage drop (%) cos φ = 1 2.38 2.42 1.98 2.00<br />

Voltage drop (%) cos φ = 0,8 4.81 4.51 4.28 5.19<br />

Magnetising current (%) 6 5 3.1 2.3<br />

Length (mm) 784 784 925 925<br />

Width (mm) 574 574 652 652<br />

Height (mm) 720 720 830 830<br />

Total weight (kg) 370 375 530 560<br />

Weight of oil filling (kg) 100 75 100 110<br />

17


TED TTT - 5, 10, 16, 25, 32 kVA<br />

TYPE<br />

Three-phase transformer for three-phase networks. Caste in<br />

resin, corrosion resistant, water-tight, plugin connection<br />

designed for directly buried installation.<br />

Protection degree : IP 68<br />

Primary voltage : 5500 V (1)<br />

Primary winding insulation level : 7.2 kV<br />

Secondary no-load voltage : 410 V (2)<br />

Secondary winding insulation level : 1.1 kV<br />

Coupling : Yzn 11<br />

Dielectric : oil<br />

Power rating : 5 - 10 - 16 - 25 - 32 kVA<br />

Nominal power depending on public<br />

lighting standards : 4 - 8 - 12.8 - 20 - 25.6 kVA<br />

<strong>Transformers</strong> comply with NFC 52 410 standards.<br />

OPERATING CONDITIONS<br />

Environmental condition AD7 : can be partly or completely<br />

immersed in water for a limited time period.<br />

MV INLET<br />

a- Three-phase plug-in connection for three-phase cable,<br />

6 kV, belt or radial field type (see leaflet n°60 10471).<br />

Maximum current : 80 A<br />

Maximum overall cable diameter : 44.5 mm,<br />

maximum allowance included.<br />

On request : elbow bent terminals.<br />

b- «Lead-through» connection in transformer.<br />

TAP CHANGER FOR VOLTAGE ADJUSTMENT<br />

Adjustment by strips off voltage, Taps + 5, + 7,5 % (3).<br />

MV PROTECTION<br />

By means of three HRC fuses, rupturing capacity 15 kA.<br />

(1) On request : other voltages compatible with primary<br />

winding insulation level.<br />

(2) On request: other voltagescompatible with secondary<br />

winding insulation level.<br />

(3) Other percentagevalueson request.<br />

LV OUTLET<br />

Five- pole 6 meter-long H.07.RN.F cable,<br />

5 - 10 kVA : cross-section 6 mm²<br />

16 kVA : cross-section 16 mm²<br />

25 - 32 kVA : cross-section 25 mm²<br />

On request : four-pole plug-in terminal for H.07.RN.F.<br />

cable with maximum overall diameter of 44.5 mm.<br />

LV PROTECTION<br />

Without low voltage protection.<br />

On request:<br />

The cut-out device ensures that direct magnetic<br />

protection and thermal protection by means of a probe<br />

incorporated in the windings, breaking capacity :<br />

10 kA.<br />

Protection by HRC fuse.<br />

LV POTENTIAL CONDITION<br />

LV neutral conductor is connected to the earthing<br />

terminal inside the transformer.<br />

On request : LV neutral conductor is not connected to<br />

earthing terminal inside the transformer.<br />

EARTHING TERMINAL<br />

By means of a M10 threaded rod, connected internally to<br />

the transformer.<br />

DIELECTRIC TESTS<br />

Impulse withstand : 60 kV - wave 1 / 50<br />

Power frequency withstand voltage : 22 kV - 50 Hz<br />

- 1 minute.<br />

USER INFORMATION WRITTEN ON COVER<br />

MV cable terminal assembly instructions :<br />

manual available on request for different cable types .<br />

EQUIPMENTS<br />

The transformers are delivered with :<br />

Two HV preparation leaflets.<br />

Two non-waterproof transport plugs.<br />

BIP delivered separately.<br />

Handling ropes.<br />

One technical leaflet for assembling MV plug-in<br />

terminals.<br />

18


TED TTT 5, 10 kVA TED TTT 16 kVA<br />

TED TTT 25, 32 kVA<br />

Input Output<br />

1- Tank<br />

2- L.V. Protection (optional)<br />

3- L.V. Outlet<br />

4- M.V. Tap changer<br />

5- M.V. Three-pole plug-in terminal<br />

6- M.V. Fuse<br />

TED TTT TECHNICAL DATA - 5, 10, 16, 25, 32 kVA<br />

Power rating (kVA) 5 10 16 25 32<br />

Power output (kVA) 4 8 12.8 20 25.6<br />

Iron losses (W) 85 90 120 130 180<br />

Copper losses (W) 100 290 390 700 750<br />

Short-circuit impedance (%) 2.3 3.5 3.5 4 3.5<br />

Voltage drop (%) cos φ = 1 2.1 2.92 2.3 2.84 2.4<br />

Voltage drop (%) cos φ = 0,8 2.4 3.5 3.4 3.96 3.4<br />

Magnetising current (%) 9 5.5 4 3 3.5<br />

Length (mm) 658 658 784 925 925<br />

Width (mm) 540 540 574 652 652<br />

Height (mm) 770 770 870 980 980<br />

Total weight (kg) 240 250 430 550 580<br />

Weight of oil filling (kg) 40 45 90 160 140<br />

19


TEH TTT - 50, 63, 80, 100, 125, 160 kVA<br />

TYPE<br />

Outdoor, watertight, metal tank specially treated against<br />

corrosion, buriable in a visible in concrete pit.<br />

Protection level : IP 68<br />

Primary voltage : 5500 V (1)<br />

Primary winding insulation : 7.2 kV<br />

Secondary no-load voltage : 410 V (2)<br />

Secondary winding insulation : 1.1 kV<br />

Vector group : 50 kVA : Yzn 11<br />

80 - 100 kVA : Dyn 11<br />

Dielectric : oil<br />

Rated power : 50 - 80 - 100 - 125 - 160 kVA<br />

Nominal power depending on public lighting standards :<br />

40 - 50.4 - 64 - 80 - 100 - 128 kVA<br />

The transformers conform to NFC 52 410 standards.<br />

CONDITIONS OF USE<br />

Environment class AD7 : can be partially or wholly<br />

immersed in water for limited time period.<br />

MV CONNECTION<br />

a- Right three p-hase, plug-in terminals with shield for<br />

three- phase, 6 kV, belt or radial field type cable (see<br />

leaflet ). 60 10472)<br />

Maximum current : 80 A<br />

Maximum cable diameter : 44,5 mm (maximum<br />

allowance included)<br />

Optional : bent plug-in terminals.<br />

b- «Lead-through» connection of the network to the<br />

Transformer.<br />

TAP CHANGER FOR VOLTAGE ADJUSTMENT<br />

By switch, only to be operated off-load<br />

Off-load adjustment plugs : + 5, + 7,5 % (3)<br />

MV PROTECTION<br />

By three H.R.C. fuses with breaking capacity 15 kA<br />

(1) Other voltage values on request ; must be compatible with<br />

insulation level of primary winding (7,2 kV)<br />

(2) Other voltage values on request ; must be compatible with<br />

insulation level of secondary winding (1,1 kV)<br />

(3) Other percentages on request<br />

LV OUTPUT<br />

Four single-pole 6 metre-long H.07.RN.F cable<br />

50 - 63 - 80 kVA : 1 x 35 mm² cross section<br />

100 kVA : 1 x 50 mm² cross section<br />

125 kVA : 1 x 70 mm² cross section<br />

160 kVA : 1 x 70 mm² cross section<br />

LV PROTECTION<br />

Without low voltage protection. Three- thermal probes<br />

incorporated in the windings are opened on the H 07 RNF<br />

2 x 2,5 mm² cable and ensure thermal protection of<br />

equipment.<br />

LV ELECTRICAL POSITION<br />

LV neutral is connected to earth terminal inside the<br />

transformer.<br />

Optional : neutral not connected inside the transformer<br />

EARTH CONNECTION<br />

The rods are welded onto the cover and tank.<br />

DIELECTRIC TESTS<br />

Impulse withstand voltage : 60 kV - wave 1 / 50<br />

Power frequency withstand : 22 kV - 50 Hz - 1 minute<br />

USER INSTRUCTIONS WRITTEN<br />

CLEARLY ON COVER<br />

MV cable terminal assembly instructions :<br />

technical leaflets available on request, according to cable<br />

type.<br />

EQUIPMENTS<br />

The transformers are delivered with:<br />

Two HV preparation leaflets.<br />

Non-waterproof transport plugs.<br />

BIP delivered separately.<br />

Handling ropes.<br />

One technical leaflet for assembing MV plug-in<br />

terminals.<br />

20


TEH TTT TECHNICAL DATA - 50, 63, 80, 100, 125, 160 kVA<br />

Power rating (kVA) 50 63 80 100 125 160<br />

Power output (kVA) 40 50.4 64 80 100 128<br />

Iron losses (W) 200 280 295 320 375 395<br />

Copper losses (W) 780 850 1080 1330 1700 2350<br />

Short-circuit impedance (%) 3.5 3.5 3.5 4 4 4<br />

Vector group Yzn11 Dyn11 Dyn11 Dyn11 Dyn11 Dyn11<br />

Magnetising current (%) 2.8 2.6 2.6 2.4 2.2 2.1<br />

Length (mm) 1042 1090 1090 1090 1122 1122<br />

Width (mm) 545 585 595 595 627 627<br />

Height (mm) 837 937 937 937 937 1037<br />

Total weight (kg) 650 770 805 845 970 1010<br />

Oil weight (kg) 110 150<br />

160 160 210 210<br />

21


GENERAL INFORMATION<br />

THREE-POLE TERMINAL : 5500 V - 80 A<br />

This terminal can receive a large number of medium<br />

voltage cables:<br />

Belt cable,<br />

Radial field cable,<br />

Twisted three-pole cable.<br />

It is made up of two parts:<br />

1- A point entirely moulded to transformer with female<br />

contacts (3 phases and 1 screen)<br />

2- The plug to be made on cable, which comprises body of<br />

plug, male pins & watertight parts.<br />

PROTECTION AGAINST WATER PENETRATION<br />

Carried out at four levels:<br />

1- Between watertight sheath and sealing ring (4) by a<br />

thermoretractable sheath (1).<br />

2- Between e plug and point by a a O-ring seal (11).<br />

3- Between phase conductor and phase contactor (6) by<br />

thermo retractable sheath (10).<br />

4- Extra insulation is provided by insulating liquid BIP<br />

inside the terminal compartment. It acts as a density dielectric<br />

allowing water to be kept on the surface, which<br />

might otherwise get into terminal in the event of cable<br />

damage.<br />

ELECTRICAL CHARACTERISTICS<br />

This terminal allows the transporting of maximum 80 A<br />

intensity.<br />

The three -pole terminal is designed with sufficient leak<br />

lines to keep to the 7.2 kV class and support all UTE tests<br />

planned.<br />

MECHANICAL CHARACTERISTICS<br />

The sealing ring lets in cables with maximum sheath diametre<br />

44.5 mm.<br />

CONNECTORS<br />

Made of brass with sheaths set in copper.<br />

THREE-POLE PLUG MODEL<br />

There are two types of three- pole plugs:<br />

1- a right three- pole plug, standard model<br />

2- An elbow -bent type three- pole plug (optional).<br />

This plug reduces the size of set and facilitates transformer<br />

installation. The design of the terminal allows greater<br />

latitude orientation.<br />

IMPORTANT<br />

Essential requirements to be communicated on order:<br />

Cable type<br />

Cable cross section<br />

Terminal model (right or elbow-bent)<br />

Supply of a cable sample, if it is specially designed.<br />

22


3<br />

Assembled right<br />

three-pole plug<br />

1<br />

2<br />

4<br />

11<br />

5<br />

10<br />

8<br />

6<br />

3<br />

1<br />

2<br />

5<br />

4<br />

11<br />

} or<br />

9<br />

7<br />

RIGHT SIDE THREE-POLE PLUG<br />

10<br />

6<br />

8 9<br />

} or<br />

AN ELBOW TYPE THREE-POLE PLUG<br />

1 - Thermo- retractable sleeve<br />

2 - Clamping nut<br />

3 - Mastic<br />

4 - 90° elbow joint with sealing sleeve<br />

5 - Body of plug<br />

6 - Phase contact pin<br />

7 - Shield contact pin<br />

8 - Phase contact nut<br />

9 - Shield contact nut<br />

10 - Thermo- retractable sleeve<br />

11 - O ring seal<br />

1<br />

7<br />

1 - Thermo-retractable sleeve<br />

2 - Clamping nut<br />

3 - Mastic<br />

4 - Sheath<br />

5 - Body of plug<br />

6 - Phase contact pin<br />

7 - Shield contact pin<br />

8 - Phase contact nut<br />

9 - Shield contact nut<br />

10 - Thermo- retractable sleeve<br />

11 - O ring seal<br />

1<br />

Plugged in and then<br />

waterproofed<br />

three-pole plug<br />

Assembled elbow bend type<br />

three-pole plug<br />

23


RECOMMENDED TYPES OF CABLE<br />

Please note that the use of synthetic cables has become widespread over the last few years since the rapid<br />

development of new types of material. The use of PRC cables is now recommended.<br />

These cables must have the following characteristics :<br />

Standard : NF C 33-220<br />

Voltage between phases : 6 kV<br />

Conductor : class 2<br />

Copper conductor<br />

EPR insulation<br />

Filling<br />

Semi-conductor tape<br />

Copper tape<br />

Paper covered matress<br />

Armour covered<br />

Outside sheath<br />

Copper conductor<br />

Semi conductor<br />

PR insulation<br />

Semi conducting sheath<br />

Copper shield<br />

Outside sheath<br />

Cable cross<br />

section<br />

(mm²)<br />

3 x 1 x 10<br />

Cable cross<br />

section<br />

(mm²)<br />

Non-radical field three-pole 6 / 6kV cable<br />

Exterior<br />

diameter<br />

maximum<br />

(mm)<br />

Acceptable<br />

intensity (A)<br />

Buried Unburied<br />

3 x 10 33 72 62<br />

3 x 16 35 94 81<br />

3 x 25 39.5 120 105<br />

3 x 35 43 145 130<br />

Curved ribbon : 9 x the exterior diameter<br />

Twisted three-pole 3.6 / 6 kV cable<br />

Exterior<br />

diameter<br />

maximum (mm)<br />

Sheath O-Ring<br />

18 36<br />

Curved ribbon : 9 x the exterior diameter on the O-ring.<br />

Acceptable<br />

intensity (A)<br />

Buried Unburied<br />

3 x 1 x 16 19.6 39.5 125 120<br />

3 x 1 x 25 21.2 42.5 160 155<br />

3 x 1 x 35 22.4 45 190 190<br />

97<br />

92<br />

24


TYPE<br />

NETWORK ACCESSORIES<br />

Dead end box, junction boxes and derivation<br />

Cast in resin, corrosion resistant, watertight, for<br />

directly buried installations with plug-in terminals.<br />

Isolation voltage : 7.2 kV<br />

Operation voltage : 5.5 kV<br />

Maximum current : 80 A<br />

WORKING CONDITIONS<br />

Environment class: AD7: can be partially or totally<br />

immersed in water temporarily.<br />

Box 1A<br />

(Dead end box)<br />

Box 1A / 1D<br />

(Junction box)<br />

CONNECTION<br />

These different boxes made up of unpluggable<br />

three- pole terminals can receive either a three -pole 6/6<br />

kV cable, a radial field 3.6/6 kV cable, or a bent type<br />

three-pole cable (see notice n°60 10472).<br />

Maximum cable diameter: 44.5 mm, maximum<br />

tolerance included.<br />

They are delivered with the necessary cable end<br />

pre-paration equipment, as well as disposable blanking<br />

off taps.<br />

On request:<br />

Bent plug-in terminals.<br />

Watertight blanking off taps.<br />

Box 1A / 2D<br />

(T-junction box)<br />

Length Width Height Weight<br />

1A Ø 135<br />

374 9 kg<br />

1A / 1D 270 130 375 15 kg<br />

1A / 2D 270 270 375 22 kg<br />

1A / 3D 270 270 375 31 kg<br />

Box 1A / 3D<br />

(Cross type junction)<br />

25


SYSTEM<br />

INTERLOCKING<br />

Thanks to an interlocking system, access to TED transformers and connection interface depend on the earthing and<br />

short circuiting of cabling supplied at origin. This is carried out by an interlocking key together with a Ronis or<br />

Profalux key.<br />

MANHOLE LOCK<br />

The interlocking key can activate a safety<br />

lock N° 7 to release the grid located<br />

inside the inspection manhole between<br />

access covering and transformer.<br />

Only specific parts corresponding to<br />

figures 5, 7 and 8 are listed in <strong>Augier</strong> rates.<br />

LOCKING THE TED TRANSFORMER TERMINALS<br />

If the manhole locking system cannot be used, a terminal locking system can be installed directly on the TED<br />

transformer. The operating principle is the same as that of manhole lock: with a locknut.<br />

Example of locking terminals<br />

Bipolar box<br />

1A / 1D<br />

TED MMX<br />

10 kVA<br />

1 - Fixation device<br />

2 - Washer<br />

3 - Stainless steel nut<br />

4 - Wire mesh<br />

5 - Nylon cap<br />

6 - HM 10 Screw<br />

7 - Special Nut<br />

8 - Cap<br />

TED TTT<br />

16 kVA<br />

26


TERMINAL INSULATION LIQUID :<br />

BLUE BIP<br />

INSTRUCTION FOR INJECTING BIP IN<br />

TRANSFORMER TAPS<br />

1- Preheat the BIP to about 35°C to facilitate<br />

pouring.<br />

2- Use a syringe to obtain the necessary quantity of BIP<br />

(see table below).<br />

3- Inject the BIP into tap.<br />

4- Repeat the operation for the other taps.<br />

WARNING : do not exceed the quantity of BIP,<br />

otherwise the excess liquid will automatically leak outside<br />

the terminal when the plug is inserted.<br />

Note: BIP is a dielectric which is denser than water.<br />

Therefore if water penetrates the terminal as a result of<br />

incorrect plugging in or damage to the cable, it remains on<br />

the surface.<br />

All our equipment with plug-in terminals is supplied with<br />

BIP (TED, boxes, ...). The BIP is delivered separately.<br />

WARNING : removal of a plug results in a loss of BIP<br />

and the BIP level in the terminal should therefore be topped<br />

up (added) (10cl for the three phase terminal).<br />

BIP topping up method: see diagram.<br />

NOTE : please contact us for your BIP purchases.<br />

Necessary « BIP » quantity for a tap<br />

Quantity Tap type<br />

10 ml Two-pole MV concentric plug-in terminal 6² - 10² Model « B »<br />

25 ml Two-pole MV concentric plug-in terminal 16² - 25² Model « B »<br />

25 ml Two-pole MV concentric plug-in terminal Model « X »<br />

10 ml Two-pole LV concentric plug-in terminal<br />

300 ml MV three-pole terminal<br />

BIP<br />

Tap on the TED lip<br />

(TED MMX 400 / 630<br />

kVA)<br />

125 ml MV three-pole terminal, without plug (on last transformer)<br />

Syringue<br />

27


AUGIER IS CERTIFIED ISO 9001 SINCE 1995<br />

With constant improvements, the manufacturer may alter information without prior warning.