DDM-9/9 Technical Data Pa p sF p sF 34 400 300 200 100 Pa 400 p sF 350 300 250 200 150 Pa 400 300 L WA7 68 DDM 9/9 E6G3704 1F 4P 1V +SCT 230 V 50 Hz 66 74 73 73 77 dB [K1] 0 100V 66 140V 75 180V 80 230V 84 0 0 1000 2000 3000 4000 qV m³/h 100 60 67 180V 73 50 59 59 140V 67 0 100V 58 0 qV 100 2000 3000 L WA7 L WA7 62 76 75 78 81 DDM 9/9 E6G3501 1F 4P 1V +SCT 70 69 73 75 74 74 76 dB 74 74 230 V 50 Hz [K3] 77 77 78 78 m³/h DDM 9/9 E6G2503 1F 4P 1V 230 V 50 Hz 72 75 74 [K5] 76 77 dB 76 80 230V 10.0 A 8.0 6.0 4.0 2.0 I 5.0 A 200 65 72 72 77 77 81 10.0 A 8.0 63 6.0 100 63 71 81 4.0 77 2.0 0 100V 61 140V 70 180V 77 230V 82 0 0 1000 2000 3000 4000 qV m³/h 77 4.0 3.0 2.0 1.0 0 I I Pa p sF 500 400 300 200 100 Pa p sF 500 400 300 200 100 Direct driven centrifugal fans / DDM / Technical Data L WA7 DDM 9/9 E6G3704 1F 4P 1V +SCT 230 V 79 dB 60 Hz [K2] 0 qV 100 2000 3000 L WA7 80 77 dB [K6] 79 81 m³/h DDM 9/9 E6G2503 1F 4P 1V 78 0 0 qV 1000 2000 3000 79 230 V 60 Hz 80 80 m³/h A 10.0 8.0 6.0 4.0 2.0 0 I 7.0 A 6.0 5.0 4.0 3.0 2.0 1.0 0 I
DDM-9/9 Direct driven centrifugal fans / DDM / Technical Data Technical Data Speed Nominal Mains Max. power Max. current control Curves motor power Poles Phases Connection frequency consumption consumption Speed DDM 9/9 W – Hz W A 1/min E6G3704 1F 4P 1V +SCT (2) [K1/K2] 600 4 1~ 50/60 1480 6.3 1380 E6G3501 1F 4P 1V +SCT (2) [K3] 550 4 1~ 50 1107 4.6 1290 E6G2503 1F 4P 1V (2) [K5/K6] 550 4 1~ 50/60 1611 6.8 1400 Technical Data Nominal capacitor voltage Motor protection class Media Temperature max. Fan weight Installation type (ISO 5801) Operating Motor ther- Thermal Density of Article Capacitor mal class protection media number DDM 9/9 μF V °C kg kg/m³ E6G3704 1F 4P 1V +SCT 25 450 IP55 F EXT 40 17 1.2 B 6M020Z E6G3501 1F 4P 1V +SCT 12.5 450 IP55 F EXT 40 17 1.2 B 6M02H5 E6G2503 1F 4P 1V 20 450 IP10 F EXT 40 17 1.2 B 6M02R8 (1) = Speed controllable via Transformer [HI] High speed, [ME] Medium speed, [LO] Low speed (2) = Speed controllable via TRIAC or Transformer Attention! We suggest to do not use the fan in the grey marked area! The noise (3) = Speed controllable via Inverter * = No speed control available ratings given in the performance curves are sound power level LWA7 , see „Technical Description“. Dimensions in mm, subject to change. DDM 9/9 E6G3704 1F 4P 1V +SCT 159.6 215.5 262.6 387 DDM 9/9 E6G3501 1F 4P 1V +SCT 262.6 387 215.5 159.6 DDM 9/9 E6G2503 1F 4P 1V +SCT 71.5 29.5 71.5 29.5 387 262.6 215.5 159.6 378.5 185 127 82 378.5 185 127 82 188 381.5 21 377 298 58 21 377 298 58 21 365 298 46 35
- Page 1 and 2: Centrifugal Fans direct driven with
- Page 3 and 4: DDM DDMB DD RZA RZP RZM TEM/REM B P
- Page 5 and 6: High performance centrifugal fans D
- Page 7 and 8: Program overview: DDM range This ki
- Page 9 and 10: DDM-120/126 Direct driven centrifug
- Page 11 and 12: DDM-133/126 Direct driven centrifug
- Page 13 and 14: DDM-133/190 Direct driven centrifug
- Page 15 and 16: DDM-146/190 Direct driven centrifug
- Page 17 and 18: DDM-225/240 Direct driven centrifug
- Page 19 and 20: DDM-280/204 Direct driven centrifug
- Page 21 and 22: DDM-7/7 Direct driven centrifugal f
- Page 23 and 24: DDM-7/7 Direct driven centrifugal f
- Page 25 and 26: DDM-7/7 Direct driven centrifugal f
- Page 27 and 28: DDM-7/9 Direct driven centrifugal f
- Page 29 and 30: DDM-9/7 Direct driven centrifugal f
- Page 31 and 32: DDM-9/7 Direct driven centrifugal f
- Page 33 and 34: DDM-9/7 Direct driven centrifugal f
- Page 35: DDM-9/7 TIGHT Direct driven centrif
- Page 39 and 40: DDM-9/9 Direct driven centrifugal f
- Page 41 and 42: DDM-9/9 Direct driven centrifugal f
- Page 43 and 44: DDM-9/9 Direct driven centrifugal f
- Page 45 and 46: DDM-9/9 TIGHT Direct driven centrif
- Page 47 and 48: DDM-10/8 Direct driven centrifugal
- Page 49 and 50: DDM-10/8 Direct driven centrifugal
- Page 51 and 52: DDM-10/8 Direct driven centrifugal
- Page 53 and 54: DDM-10/8 Direct driven centrifugal
- Page 55 and 56: DDM-10/10 Direct driven centrifugal
- Page 57 and 58: DDM-10/10 Direct driven centrifugal
- Page 59 and 60: DDM-10/10 Direct driven centrifugal
- Page 61 and 62: DDM-10/10 Direct driven centrifugal
- Page 63 and 64: DDM-10/10 Direct driven centrifugal
- Page 65 and 66: DDM-12/9 Direct driven centrifugal
- Page 67 and 68: DDM-12/9 Direct driven centrifugal
- Page 69 and 70: DDM-12/12 Direct driven centrifugal
- Page 71 and 72: DDM-12/12 Direct driven centrifugal
- Page 73 and 74: DDM-15/15 Direct driven centrifugal
- Page 75 and 76: Fittings / Accessories Accessories
- Page 77 and 78: Fittings / Accessories Increased co
- Page 79 and 80: Fittings / Accessories Wiring Diagr
- Page 81 and 82: Description Fan lifespan Media Moto
- Page 83 and 84: Program overview: DDMB range This k
- Page 85 and 86: DDMB-7/7 Direct driven centrifugal
DDM-9/9<br />
Technical Data<br />
Pa<br />
p sF<br />
p sF<br />
34<br />
400<br />
300<br />
200<br />
100<br />
Pa<br />
400<br />
p sF<br />
350<br />
300<br />
250<br />
200<br />
150<br />
Pa<br />
400<br />
300<br />
L WA7<br />
68<br />
DDM 9/9 E6G3704 1F 4P 1V +SCT<br />
230 V<br />
50 Hz<br />
66<br />
74<br />
73<br />
73<br />
77 dB<br />
[K1]<br />
0<br />
100V 66 140V 75 180V 80 230V 84 0<br />
0 1000 2000 3000 4000<br />
qV m³/h<br />
100<br />
60 67 180V<br />
73<br />
50<br />
59<br />
59<br />
140V<br />
67<br />
0<br />
100V<br />
58<br />
0<br />
qV 100 2000 3000<br />
L WA7<br />
L WA7<br />
62<br />
76<br />
75<br />
78<br />
81<br />
DDM 9/9 E6G3501 1F 4P 1V +SCT<br />
70<br />
69<br />
73<br />
75<br />
74<br />
74<br />
76 dB<br />
74<br />
74<br />
230 V<br />
50 Hz<br />
[K3]<br />
77<br />
77<br />
78<br />
78<br />
m³/h<br />
DDM 9/9 E6G2503 1F 4P 1V<br />
230 V<br />
50 Hz<br />
72<br />
75<br />
74<br />
[K5]<br />
76<br />
77 dB<br />
76 80<br />
230V<br />
10.0<br />
A<br />
8.0<br />
6.0<br />
4.0<br />
2.0<br />
I<br />
5.0<br />
A<br />
200<br />
65<br />
72<br />
72<br />
77<br />
77<br />
81<br />
10.0<br />
A<br />
8.0<br />
63<br />
6.0<br />
100<br />
63 71<br />
81<br />
4.0<br />
77<br />
2.0<br />
0<br />
100V 61 140V 70 180V 77 230V 82 0<br />
0 1000 2000 3000 4000<br />
qV m³/h<br />
77<br />
4.0<br />
3.0<br />
2.0<br />
1.0<br />
0<br />
I<br />
I<br />
Pa<br />
p sF<br />
500<br />
400<br />
300<br />
200<br />
100<br />
Pa<br />
p sF<br />
500<br />
400<br />
300<br />
200<br />
100<br />
Direct <strong>driven</strong> centrifugal fans / DDM / Technical Data<br />
L WA7<br />
DDM 9/9 E6G3704 1F 4P 1V +SCT<br />
230 V<br />
79 dB 60 Hz<br />
[K2]<br />
0<br />
qV 100 2000 3000<br />
L WA7<br />
80<br />
77 dB<br />
[K6]<br />
79<br />
81<br />
m³/h<br />
DDM 9/9 E6G2503 1F 4P 1V<br />
78<br />
0<br />
0<br />
qV 1000 2000 3000<br />
79<br />
230 V<br />
60 Hz<br />
80<br />
80<br />
m³/h<br />
A<br />
10.0<br />
8.0<br />
6.0<br />
4.0<br />
2.0<br />
0<br />
I<br />
7.0<br />
A<br />
6.0<br />
5.0<br />
4.0<br />
3.0<br />
2.0<br />
1.0<br />
0<br />
I