AT 28/28 Technical Data Impeller Data Impeller Data Impeller diameter Number of blades Dr z 710 56 mm Impeller weight Density of media Moment of Inertia J 3.867 kgm² Tolerance class (DIN 24166) Performance Curves Please note coloured area! N all types suitable N do not use in this area 2500 Pa 2000 1500 1000 p F 88 800 600 500 400 300 200 150 P r m 35 kg r 1 1.2 kg/m³ 2 100 0.37 80 80 65 70 75 60 Normal operation area 50 5000 6000 8000 10000 15000 20000 30000 40000 60000 80000 100000 1.4 2 3 4 5 6 7 8 9 10 14 20 30 q V v 2 2 p d2 0.55 0.75 SX 1.1 3 4 5 6 7 8 9 10 14 20 30 3 4 6 8 10 20 40 60 80 100 200 400 ∆L Wrel4 (A) Duty Speed point 1/min dB SX 600 3 SX 400 2 SX 250 2 qV opt 600 2 qV opt 400 2 qV opt 250 1 DX 600 2 DX 400 2 DX 250 1 1.5 2.2 3.0 4.0 5.5 7.5 11 DX kW 18.5 15 48% 57 85 L WA 7 63 125 250 500 1000 2000 4000 8000 Hz 9 10 -1 -3 -9 -11 -13 -19 dB 14 2 1 -3 -7 -9 -14 -18 dB 12 3 2 -4 -6 -9 -15 -19 dB 7 8 -1 -2 -8 -9 -12 -16 dB 11 0 1 -3 -6 -8 -12 -18 dB 8 3 1 -4 -5 -9 -14 -19 dB 7 5 -2 -5 -7 -7 -10 -13 dB 8 -1 -1 -5 -5 -7 -10 -14 dB 4 1 -3 -4 -5 -8 -11 -17 dB 30 66 90 95 69 η r 100 65 Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Relative sound power level for inlet side L Wrel7 at octave centre frequencies f c Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 54 105 dB 40 42 600 800 1000 m³/h m³/s m/s Pa 1/min 900 800 700 600 550 500 450 400 350 300 250 200 N W 19 17 15 13 12 11 10 8 7 6 5 4 AT TIC 63 125 250 500 1000 2000 4000 8000 Hz 13 14 2 -1 -7 -9 -12 -18 dB 18 5 3 -1 -5 -8 -13 -19 dB 16 6 3 -2 -4 -8 -15 -22 dB 11 11 2 -1 -6 -8 -11 -16 dB 15 3 3 -1 -5 -7 -12 -19 dB 12 6 3 -2 -4 -8 -14 -22 dB 11 9 2 -2 -5 -6 -9 -13 dB 12 2 2 -3 -4 -6 -10 -16 dB 7 4 0 -2 -3 -7 -12 -20 dB P b Measured in installation B according to ISO 5801: Relative sound power level for discharge side L Wrel4 at octave centre frequencies f c

AT 28/28 Dimensions in mm, subject to change. AT TIC-28/28 127 kg 1238 1118 870 136 485 12 920 966 17 × 22 ø40 8 43 90 ø11 400 400 870 910 946 400 400 863 903 939 1311 = 1171 = Belt Driven Centrifugal Fans / AT / Technical Data = 920 1060 = 52 718 870 58 1121 488 1294 38 89

<strong>AT</strong> 28/28<br />

Dimensions in mm, subject to change.<br />

<strong>AT</strong> TIC-28/28 127 kg<br />

1238<br />

1118<br />

870 136<br />

485<br />

12<br />

920<br />

966<br />

17 × 22<br />

ø40<br />

8 43<br />

90<br />

ø11<br />

400 400<br />

870<br />

910<br />

946<br />

400 400<br />

863<br />

903<br />

939<br />

1311<br />

= 1171 =<br />

Belt Driven <strong>Centrifugal</strong> <strong>Fans</strong> / <strong>AT</strong> / Technical Data<br />

= 920<br />

1060<br />

=<br />

52<br />

718<br />

870<br />

58<br />

1121<br />

488<br />

1294<br />

38<br />

89