AT 20/20 Technical Data Impeller Data Impeller Data Impeller diameter Number of blades Dr z 516 42 mm Impeller weight Density of media Moment of Inertia J 1.175 kgm² Tolerance class (DIN 24166) Performance Curves Please note coloured area! N all types suitable N do not use in this area 2500 Pa 2000 1500 1000 p F 76 800 600 500 400 300 200 150 100 80 60 50 0.09 40 2000 q V 1.4 v2 p d2 P r 0.18 2 SX 3000 0.37 0.55 0.75 1.1 1.5 2.2 60 3.0 4.0 5.5 65 kW 7.5 70 11 54% 75 15 59 80 85 m 20 kg r 1 1.2 kg/m³ 2 4000 5000 6000 8000 10000 15000 20000 30000 40000 2 3 4 5 6 7 8 9 10 14 20 30 ∆L Wrel4 (A) Duty Speed point 1/min dB SX 1100 3 SX 700 3 SX 400 2 qV opt 1100 3 qV opt 700 2 qV opt 400 2 DX 1100 3 DX 700 2 DX 400 2 Normal operation area 1 DX L WA 7 4 6 8 10 20 40 60 80 100 200 400 65 22 90 68 95 65 100 2 3 4 5 6 7 8 9 10 14 m³/s 63 125 250 500 1000 2000 4000 8000 Hz 8 2 5 -4 -9 -12 -14 -18 dB 11 8 -1 -2 -9 -10 -13 -19 dB 12 4 2 -5 -6 -8 -14 -20 dB 3 -1 5 -4 -8 -11 -12 -17 dB 6 7 -1 -2 -8 -9 -12 -18 dB 10 3 2 -4 -6 -8 -13 -20 dB -2 -5 1 -3 -6 -9 -10 -14 dB 0 2 -2 -3 -6 -7 -11 -16 dB 4 0 0 -4 -5 -8 -12 -18 dB η r Belt Driven Centrifugal Fans / AT / Technical Data Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Relative sound power level for inlet side L Wrel7 at octave centre frequencies f c Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. 58 48 105 dB m³/h m/s 600 800 Pa 1/min 1400 1300 1200 1000 900 800 700 600 500 400 300 W 8 7 350 6 5 250 4 N 24 22 20 1100 19 17 15 14 12 10 AT TIC 63 125 250 500 1000 2000 4000 8000 Hz 13 8 9 -1 -8 -11 -12 -16 dB 17 13 2 0 -8 -8 -11 -18 dB 16 7 4 -4 -4 -7 -13 -21 dB 8 4 9 -1 -6 -10 -11 -15 dB 12 12 2 0 -7 -8 -11 -17 dB 15 6 4 -3 -5 -7 -12 -21 dB 1 1 5 0 -4 -7 -8 -14 dB 5 7 2 0 -4 -6 -10 -15 dB 9 4 3 -2 -4 -7 -12 -19 dB P b Measured in installation B according to ISO 5801: Relative sound power level for discharge side L Wrel4 at octave centre frequencies f c

AT 20/20 Dimensions in mm, subject to change. AT TIC-20/20 78 kg 900 830 630 97 369 10 670 706 13 × 18 ø35 8 38 65 ø11 275 275 630 670 706 275 275 622 662 698 967 = 827 = Belt Driven Centrifugal Fans / AT / Technical Data = 632 772 = 52 520 629 58 833 372 950 38 77

<strong>AT</strong> 20/20<br />

Dimensions in mm, subject to change.<br />

<strong>AT</strong> TIC-20/20 78 kg<br />

900<br />

830<br />

630 97<br />

369<br />

10<br />

670<br />

706<br />

13 × 18<br />

ø35<br />

8 38<br />

65<br />

ø11<br />

275 275<br />

630<br />

670<br />

706<br />

275 275<br />

622<br />

662<br />

698<br />

967<br />

= 827 =<br />

Belt Driven <strong>Centrifugal</strong> <strong>Fans</strong> / <strong>AT</strong> / Technical Data<br />

= 632<br />

772<br />

=<br />

52<br />

520<br />

629<br />

58<br />

833<br />

372<br />

950<br />

38<br />

77