Centrifugal Fans direct driven with scroll - Nicotra Gebhardt
Centrifugal Fans direct driven with scroll - Nicotra Gebhardt Centrifugal Fans direct driven with scroll - Nicotra Gebhardt
RZP 11-0225-EC-12 EKE 07-0065-5E-IM Technical data RZP 11- EKE 07- V HZ kW A 1/min °C ~kg 0225-EC-12 0065-5E-IM 230 1~ 50/60 0.85 3.7 3400 IP54 F 40 20 Dimensions in mm, subject to change. ZKF 15-1717 ZKE 15-1717 399 ZSG 03-0225 191 212 26 288 468 194 100 30 130 176 RZP 11- Anti Vibration Rubber Buffers ZBD 0225-EC-12 ZBD 010506A 26 220 270 26 255 447 Direct driven centrifugal fans / RZP / Technical data 10.5 180 322 348 180 10 2 x 100 286 322 348 LG 0 LG 90 LG 180 LG 270 RD 0 RD 90 RD 180 RD 270 Accessories Control electronics Voltage Phases Mains frequency The system efficiency η esd is the efficiency of the whole system, Fan–Motor–Control electronics. Max. power Max. current consumption consumption Nominal motor speed Motor protection class Motor thermal class Max. media temperature Weight Attention! The performance curves relates to the fan in combination with the given Control electronics. 205
RZP 11-0250-EC-12 EKE 07-0065-5E-IM Technical data Please note coloured area! N do not use in this area p sF 206 Pa 2000 1500 1200 1000 800 600 500 400 300 200 150 120 100 80 60 50 40 600 800 qV q V P 1S 0.2 0.15 0.2 0.3 1000 0.4 50 % 69 72 55 esd (N max) 1500 2000 2500 3000 4000 5000 m³/h 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.5 m³/s 57 78 75 LWA7 Determination of the Octave level Inlet side Relative sound power level LWrel7 at octave band correction factors fc . Speed 0.5 0.6 kW 0.8 1.0 55 81 Direct driven centrifugal fans / RZP / Technical data 84 50 40 87 dB 30 20 3200 1/min 2900 2600 2300 2000 1800 1600 N r 1 = 1.15 kg/m³ 63 125 250 500 1000 2000 4000 8000 Hz ≤2342 1/min 0.70–1.4 q Vopt 5 6 0 4 3 10 18 28 dB >2342 1/min 0.70–1.4 q Vopt 9 12 7 5 3 8 12 22 dB Discharge side Relative sound power level L Wrel6 at octave band correction factors f c . Speed Normal operation area Duty point Duty point Density of media 1.15 kg/m³. Measured in installation A according to ISO 5801 (unducted). 63 125 250 500 1000 2000 4000 8000 Hz ≤2342 1/min 0.70–1.4 q Vopt 9 8 1 1 5 11 21 31 dB >2342 1/min 0.70–1.4 q Vopt 12 11 8 1 5 8 16 27 dB
- Page 1 and 2: Centrifugal Fans direct driven with
- Page 3 and 4: DDM DDMB DD RZA RZP RZM TEM/REM B P
- Page 5 and 6: High performance centrifugal fans D
- Page 7 and 8: Nicotra Gebhardt technologies like
- Page 9 and 10: proSELECTA II Fan Selection Program
- Page 11 and 12: 170 Highest system performance and
- Page 13 and 14: RZA 11-0225 Technical Data Density
- Page 15 and 16: RZA 11-0250 Technical Data Density
- Page 17 and 18: RZA 11-0280 Technical Data Density
- Page 19 and 20: RZA 11-0315 Technical Data Density
- Page 21 and 22: RZA 11-0355 Technical Data Density
- Page 23 and 24: RZA 11-0400 Technical Data Density
- Page 25 and 26: RZA 11-0450 Technical Data Density
- Page 27 and 28: RZA 11-0500 Technical Data Density
- Page 29 and 30: RZA 11-0560 Technical Data Density
- Page 31 and 32: RZA 11-0225/-0560 Specifications Fa
- Page 33 and 34: Fittings / Accessories Flexible Con
- Page 35 and 36: Fittings / Accessories Volume flow
- Page 37 and 38: Description Motors Electric connect
- Page 39 and 40: Highest system performance and best
- Page 41 and 42: RZP 11-0200-EC-11 EKE 07-0065-5E-IM
- Page 43: RZP 11-0225-EC-12 EKE 07-0065-5E-IM
- Page 47 and 48: RZP 11-0280-EC-31 EKE 07-0065-5E-IM
- Page 49 and 50: RZP 11-0315-EC-31 EKE 07-0065-5E-IM
- Page 51 and 52: RZP 11-0315-EC-51 T06-745.2.340-300
- Page 53 and 54: RZP 11-0355-EC-52 T06-745.2.340-300
- Page 55 and 56: RZP 11-0400-EC-52 T06-745.2.340-300
- Page 57 and 58: RZP 11-0200/-0400 Specifications Fa
- Page 59 and 60: T06-745.2.340-300 Description 300 2
- Page 61 and 62: Fittings / Accessories Anti Vibrati
- Page 63 and 64: Description Safety Performance data
- Page 65 and 66: 227
- Page 67 and 68: Accessories Frequency converter Tec
- Page 69 and 70: Accessories Universal control devic
- Page 71 and 72: Differential pressure sensor Direct
- Page 73 and 74: Accessories Isolator ESH 22 Technic
- Page 75: Nicotra Gebhardt worldwide SPAIN Ct
RZP 11-0225-EC-12<br />
EKE 07-0065-5E-IM<br />
Technical data<br />
RZP 11- EKE 07- V HZ kW A 1/min °C ~kg<br />
0225-EC-12 0065-5E-IM 230 1~ 50/60 0.85 3.7 3400 IP54 F 40 20<br />
Dimensions in mm, subject to change.<br />
ZKF 15-1717 ZKE 15-1717 399<br />
ZSG 03-0225<br />
191<br />
212<br />
26<br />
288<br />
468<br />
194 100<br />
30 130<br />
176<br />
RZP 11-<br />
Anti Vibration Rubber Buffers<br />
ZBD<br />
0225-EC-12 ZBD 010506A<br />
26<br />
220<br />
270<br />
26<br />
255<br />
447<br />
Direct <strong>driven</strong> centrifugal fans / RZP / Technical data<br />
10.5<br />
180<br />
322<br />
348<br />
180<br />
10<br />
2 x 100<br />
286<br />
322<br />
348<br />
LG 0 LG 90 LG 180 LG 270 RD 0 RD 90 RD 180 RD 270<br />
Accessories<br />
Control<br />
electronics Voltage Phases<br />
Mains<br />
frequency<br />
The system efficiency η esd is the efficiency of the whole system, Fan–Motor–Control<br />
electronics.<br />
Max. power Max. current<br />
consumption consumption<br />
Nominal<br />
motor speed<br />
Motor<br />
protection<br />
class<br />
Motor<br />
thermal class<br />
Max. media<br />
temperature Weight<br />
Attention! The performance curves relates to the fan in combination <strong>with</strong> the given<br />
Control electronics.<br />
205