Centrifugal Fans direct driven with scroll - Nicotra Gebhardt
Centrifugal Fans direct driven with scroll - Nicotra Gebhardt Centrifugal Fans direct driven with scroll - Nicotra Gebhardt
Fittings / Accessories Volumeter p in p in 2 qV = K × — × pDü Direct driven centrifugal fans / RZA / Accessories With the flow measuring device it is possible to easilymeasure / monitor the flow rate after the fan is installed. A pressure tapping at a predetermined position on the inlet cone is provided whereby the differential pressure in relation to the static pressure is measured in front ofthe inlet cone in a static atmosphere. • volume flow qV [m³/h] • calibration factor K [m²s/h] • density of media r [kg/m³] • pressure difference at cone DpDü [Pa] In order to calculate the flow rate, a calibrating factor "K" is required. This factor is determined by comparativemeasurement on a standard test rig. • • • Measuring connector in inlet cone Hose pipe to connecting piece in the side wall Connecting piece (external diameter of 6mm) for the pressure measurement Standard-calibration faktor K10
Fittings / Accessories Volume flow determination Electrical accessories 194 Direct driven centrifugal fans / RZA / Accessories With the represented chart and a measured difference pressure at the nozzle can streamed determined become the volumes in the indicated density. The chart can be used also to the determination of the needed pressure area of a manometer. In addition the difference pressure is determined at the nozzle for the maximally appearing volume current with the chart. m³/h q V 32000 28000 24000 20000 16000 12000 8000 4000 0 0 500 1000 1500 2000 p FI Pa RZA 11- 0560 0500 0450 0400 0355 0315 0280 0250 0225 Electrical accessories (Frequency converter, Differential pressure sensor, Universal control device, Isolator) see chapter "Accessories".
- Page 1 and 2: Centrifugal Fans direct driven with
- Page 3 and 4: DDM DDMB DD RZA RZP RZM TEM/REM B P
- Page 5 and 6: High performance centrifugal fans D
- Page 7 and 8: Nicotra Gebhardt technologies like
- Page 9 and 10: proSELECTA II Fan Selection Program
- Page 11 and 12: 170 Highest system performance and
- Page 13 and 14: RZA 11-0225 Technical Data Density
- Page 15 and 16: RZA 11-0250 Technical Data Density
- Page 17 and 18: RZA 11-0280 Technical Data Density
- Page 19 and 20: RZA 11-0315 Technical Data Density
- Page 21 and 22: RZA 11-0355 Technical Data Density
- Page 23 and 24: RZA 11-0400 Technical Data Density
- Page 25 and 26: RZA 11-0450 Technical Data Density
- Page 27 and 28: RZA 11-0500 Technical Data Density
- Page 29 and 30: RZA 11-0560 Technical Data Density
- Page 31 and 32: RZA 11-0225/-0560 Specifications Fa
- Page 33: Fittings / Accessories Flexible Con
- Page 37 and 38: Description Motors Electric connect
- Page 39 and 40: Highest system performance and best
- Page 41 and 42: RZP 11-0200-EC-11 EKE 07-0065-5E-IM
- Page 43 and 44: RZP 11-0225-EC-12 EKE 07-0065-5E-IM
- Page 45 and 46: RZP 11-0250-EC-12 EKE 07-0065-5E-IM
- Page 47 and 48: RZP 11-0280-EC-31 EKE 07-0065-5E-IM
- Page 49 and 50: RZP 11-0315-EC-31 EKE 07-0065-5E-IM
- Page 51 and 52: RZP 11-0315-EC-51 T06-745.2.340-300
- Page 53 and 54: RZP 11-0355-EC-52 T06-745.2.340-300
- Page 55 and 56: RZP 11-0400-EC-52 T06-745.2.340-300
- Page 57 and 58: RZP 11-0200/-0400 Specifications Fa
- Page 59 and 60: T06-745.2.340-300 Description 300 2
- Page 61 and 62: Fittings / Accessories Anti Vibrati
- Page 63 and 64: Description Safety Performance data
- Page 65 and 66: 227
- Page 67 and 68: Accessories Frequency converter Tec
- Page 69 and 70: Accessories Universal control devic
- Page 71 and 72: Differential pressure sensor Direct
- Page 73 and 74: Accessories Isolator ESH 22 Technic
- Page 75: Nicotra Gebhardt worldwide SPAIN Ct
Fittings / Accessories<br />
Volume flow determination<br />
Electrical accessories<br />
194<br />
Direct <strong>driven</strong> centrifugal fans / RZA / Accessories<br />
With the represented chart and a measured difference pressure at the nozzle can<br />
streamed determined become the volumes in the indicated density. The chart can be<br />
used also to the determination of the needed pressure area of a manometer. In addition<br />
the difference pressure is determined at the nozzle for the maximally appearing<br />
volume current <strong>with</strong> the chart.<br />
m³/h<br />
q V<br />
32000<br />
28000<br />
24000<br />
20000<br />
16000<br />
12000<br />
8000<br />
4000<br />
0<br />
0 500 1000 1500 2000<br />
p FI<br />
Pa<br />
RZA 11-<br />
0560<br />
0500<br />
0450<br />
0400<br />
0355<br />
0315<br />
0280<br />
0250<br />
0225<br />
Electrical accessories (Frequency converter, Differential pressure sensor, Universal<br />
control device, Isolator) see chapter "Accessories".