Appendix A – <strong>CADD</strong> Information Table Revised April 20, 2012<br />

By Level Attributes<br />

Level Name Description<br />

Color<br />

Style<br />

SN – SIGNS - PROPOSED:<br />

SN_P_Cantilever_Overhead Cantilever Overhead 10 0 2 0 100<br />

SN_P_Foundation<br />

SN_P_Signs<br />

Sign Foundations and Symbols 0 0 1 0 100<br />

CELLS PLACED ON LEVEL SN_P_Foundation:<br />

Weight<br />

Transparency<br />

Priority<br />

Cell Name Cell Library Name<br />

30” Sign Support Foundation - - - 0 100 SSFN_30P ODOT_Symbols.cel P<br />

36” Sign Support Foundation - - - 0 100 SSFN_36P ODOT_Symbols.cel P<br />

Sign Truss Support Foundation<br />

TC-7.65, 4’-5”<br />

Sign Truss Support Foundation<br />

TC-7.65, 5’-7”<br />

Sign Truss Support Foundation<br />

TC-7.65, 6’-7”<br />

Sign Truss Support Foundation<br />

TC-15.115, 5’-3”<br />

Sign Truss Support Foundation<br />

TC-15.115, 6’-7”<br />

Public Sign Symbols 10 0 1 0 100<br />

CELLS PLACED ON LEVEL SN_P_Signs:<br />

- - - 0 100 STFN_7.65-45P ODOT_Symbols.cel P<br />

- - - 0 100 STFN_7.65-57P ODOT_Symbols.cel P<br />

- - - 0 100 STFN_7.65-67P ODOT_Symbols.cel P<br />

- - - 0 100 STFN_15.115-53P ODOT_Symbols.cel P<br />

- - - 0 100 STFN_15.115-67P ODOT_Symbols.cel P<br />

1-Post Sign Back to Back - - - 0 100 SGN1BP ODOT_Symbols.cel C<br />

1-Post Sign - - - 0 100 SGN1PP ODOT_Symbols.cel C<br />

4 Signs on 1-Support - - - 0 100 SGN1SP ODOT_Symbols.cel C<br />

2-Post Sign Back to Back - - - 0 100 SGN2BP ODOT_Symbols.cel C<br />

2-Post Sign - - - 0 100 SGN2PP ODOT_Symbols.cel C<br />

4 Signs on 2-Supports - - - 0 100 SGN2SP ODOT_Symbols.cel C<br />

3-Post Sign - - - 0 100 SGN3PP ODOT_Symbols.cel C<br />

SN_P_Structure_Mount Structure Mounted Sign 10 0 2 0 100<br />

SN_P_Text Signing Text 0 0 1 0 500<br />

SN_P_Truss_Overhead Truss Overhead Sign 10 0 2 0 100<br />

C = Cosmetic<br />

P = Physical<br />

Levels Do Not<br />

Plot<br />

NOTE: * Indicates Not By Level Page 93 <strong>of</strong> 108