Appendix A – CADD Information Table Revised January 20, 2012 By Level Attributes Level Name Description DR_X_Erosion_Control Erosion Control Outline for RipRap, Rock Channel Protection and Jute Matting Color Style DR – DRAINAGE – EXISTING (cont’d): 0 1 0 0 -100 AREA PATTERNING CELLS TO BE PLACED ON LEVEL DR_X_Erosion_Control: Jute Matting (use Cross-Hatch Pattern tool) Rock Channel Protection (Pattern Cell) - - - 0 -100 Weight Transparency Priority Cell Name Cell Library Name - - - 0 -100 RCP ODOT-Symbols.cel C Rip Rap (Pattern Cell) - - - 0 -100 RIPRAP ODOT-Symbols.cel C DR_X_Flood_Boundary Flood Boundary 170 5 1 0 -100 DR_X_Floodway Floodway 167 7 0 0 -100 DR_X_Flow_Arrow DR_X_Headwall Drainage Flow Arrow Symbols 17 0 0 0 -100 CELLS PLACED ON LEVEL DR_X_Flow_Arrow: Drainage Flow Arrow - - - 0 -100 DFL-X ODOT_Drainage.cel C Drainage Headwall Symbols 10 1 0 0 -100 CELLS PLACED ON LEVEL DR_X_Headwall: Head Wall No. 1 for 15" RCP - - - 0 -100 HW1-15-X ODOT_Drainage.cel P Head Wall No. 1 for 18" RCP - - - 0 -100 HW1-18-X ODOT_Drainage.cel P Head Wall No. 1 for 21" RCP - - - 0 -100 HW1-21-X ODOT_Drainage.cel P Head Wall No. 1 for 24" RCP - - - 0 -100 HW1-24-X ODOT_Drainage.cel P Head Wall No. 1 for 30" RCP - - - 0 -100 HW1-30-X ODOT_Drainage.cel P Head Wall No. 1 for 36" RCP - - - 0 -100 HW1-36-X ODOT_Drainage.cel P Head Wall No. 1.1, 15° for 42" Pipe - - - 0 -100 HW1.1-15-42-X ODOT_Drainage.cel P Head Wall No. 1.1, 15° for 48" Pipe - - - 0 -100 HW1.1-15-48-X ODOT_Drainage.cel P Head Wall No. 1.1, 15° for 54" Pipe - - - 0 -100 HW1.1-15-54-X ODOT_Drainage.cel P Head Wall No. 1.1, 15° for 60" Pipe - - - 0 -100 HW1.1-15-60-X ODOT_Drainage.cel P Head Wall No. 1.1, 15° for 72" Pipe - - - 0 -100 HW1.1-15-72-X ODOT_Drainage.cel P Head Wall No. 1.1, 15° for 84" Pipe - - - 0 -100 HW1.1-15-84-X ODOT_Drainage.cel P Head Wall No. 1.1, 30° for 42" Pipe - - - 0 -100 HW1.1-30-42-X ODOT_Drainage.cel P Head Wall No. 1.1, 30° for 48" Pipe - - - 0 -100 HW1.1-30-48-X ODOT_Drainage.cel P C = Cosmetic P = Physical Levels Do Not Plot NOTE: * Indicates Not By Level Page 19 of 108
Appendix A – CADD Information Table Revised January 20, 2012 By Level Attributes Level Name Description DR_X_Headwall (cont’d) CELLS PLACED ON LEVEL DR_X_Headwall (cont’d): Color Style DR – DRAINAGE – EXISTING (cont’d): Weight Transparency Priority Cell Name Cell Library Name Head Wall No. 1.1, 30° for 54" Pipe - - - 0 -100 HW1.1-30-54-X ODOT_Drainage.cel P Head Wall No. 1.1, 30° for 60" Pipe - - - 0 -100 HW1.1-30-60-X ODOT_Drainage.cel P Head Wall No. 1.1, 30° for 72" Pipe - - - 0 -100 HW1.1-30-72-X ODOT_Drainage.cel P Head Wall No. 1.1, 30° for 84" Pipe - - - 0 -100 HW1.1-30-84-X ODOT_Drainage.cel P Head Wall No. 1.1 for 42" Pipe - - - 0 -100 HW1.1-42-X ODOT_Drainage.cel P Head Wall No. 1.1, 45° for 42" Pipe - - - 0 -100 HW1.1-45-42-X ODOT_Drainage.cel P Head Wall No. 1.1, 45° for 48" Pipe - - - 0 -100 HW1.1-45-48-X ODOT_Drainage.cel P Head Wall No. 1.1, 45° for 54" Pipe - - - 0 -100 HW1.1-45-54-X ODOT_Drainage.cel P Head Wall No. 1.1, 45° for 60" Pipe - - - 0 -100 HW1.1-45-60-X ODOT_Drainage.cel P Head Wall No. 1.1, 45° for 72" Pipe - - - 0 -100 HW1.1-45-72-X ODOT_Drainage.cel P Head Wall No. 1.1, 45° for 84" Pipe - - - 0 -100 HW1.1-45-84-X ODOT_Drainage.cel P Head Wall No. 1.1 for 48" Pipe - - - 0 -100 HW1.1-48-X ODOT_Drainage.cel P Head Wall No. 1.1 for 54" Pipe - - - 0 -100 HW1.1-54-X ODOT_Drainage.cel P Head Wall No. 1.1 for 60" Pipe - - - 0 -100 HW1.1-60-X ODOT_Drainage.cel P Head Wall No. 1.1 for 72" Pipe - - - 0 -100 HW1.1-72-X ODOT_Drainage.cel P Head Wall No. 1.1 for 84" Pipe - - - 0 -100 HW1.1-84-X ODOT_Drainage.cel P Head Wall No. 2.1 for 012" CMP - - - 0 -100 HW2.1-12-X ODOT_Drainage.cel P Head Wall No. 2.1 for 015" CMP - - - 0 -100 HW2.1-15-X ODOT_Drainage.cel P Head Wall No. 2.1 for 018" CMP - - - 0 -100 HW2.1-18-X ODOT_Drainage.cel P Head Wall No. 2.1 for 021" CMP - - - 0 -100 HW2.1-21-X ODOT_Drainage.cel P Head Wall No. 2.1 for 024" CMP - - - 0 -100 HW2.1-24-X ODOT_Drainage.cel P Head Wall No. 2.1 for 027" CMP - - - 0 -100 HW2.1-27-X ODOT_Drainage.cel P Head Wall No. 2.1 for 030" CMP - - - 0 -100 HW2.1-30-X ODOT_Drainage.cel P Head Wall No. 2.1 for 033" CMP - - - 0 -100 HW2.1-33-X ODOT_Drainage.cel P Head Wall No. 2.1 for 036" CMP - - - 0 -100 HW2.1-36-X ODOT_Drainage.cel P Head Wall No. 2.1 for 039" CMP - - - 0 -100 HW2.1-39-X ODOT_Drainage.cel P C = Cosmetic P = Physical Levels Do Not Plot NOTE: * Indicates Not By Level Page 20 of 108
- Page 87 and 88: Figure 304-1 File Name Type Codes B
- Page 89 and 90: SIGNAL SHEETS Notes - CN General Su
- Page 91 and 92: 306.2 GEOPAK COGO Element Names Jan
- Page 93 and 94: COGO Right of Way Elements Chains R
- Page 95 and 96: (1) Project Name: For this example,
- Page 97 and 98: 400 PLOTTING 401 General 401.1 Gene
- Page 99 and 100: 401.2.3 Shading The following are o
- Page 101 and 102: 502.2 Saved View January 18, 2013 W
- Page 103 and 104: Figure 503-2 504 CADD File Requirem
- Page 105 and 106: January 18, 2013 A sample ASCII rep
- Page 107 and 108: 504.3 Vertical Alignment ASCII Repo
- Page 110 and 111: January 18, 2013 Each horizontal al
- Page 112 and 113: January 18, 2013 504.6 Monumentatio
- Page 114 and 115: January 18, 2013 Left Offset/Right
- Page 116 and 117: January 18, 2013 The XS Reports dia
- Page 118 and 119: January 18, 2013 Select the Apply b
- Page 120 and 121: Appendix A - CADD Information Table
- Page 122 and 123: Appendix A - CADD Information Table
- Page 124 and 125: Appendix A - CADD Information Table
- Page 126 and 127: Appendix A - CADD Information Table
- Page 128 and 129: Appendix A - CADD Information Table
- Page 130 and 131: Appendix A - CADD Information Table
- Page 132 and 133: Appendix A - CADD Information Table
- Page 134 and 135: Appendix A - CADD Information Table
- Page 136 and 137: Appendix A - CADD Information Table
- Page 140 and 141: Appendix A - CADD Information Table
- Page 142 and 143: Appendix A - CADD Information Table
- Page 144 and 145: Appendix A - CADD Information Table
- Page 146 and 147: Appendix A - CADD Information Table
- Page 148 and 149: Appendix A - CADD Information Table
- Page 150 and 151: Appendix A - CADD Information Table
- Page 152 and 153: Appendix A - CADD Information Table
- Page 154 and 155: Appendix A - CADD Information Table
- Page 156 and 157: Appendix A - CADD Information Table
- Page 158 and 159: Appendix A - CADD Information Table
- Page 160 and 161: Appendix A - CADD Information Table
- Page 162 and 163: Appendix A - CADD Information Table
- Page 164 and 165: Appendix A - CADD Information Table
- Page 166 and 167: Appendix A - CADD Information Table
- Page 168 and 169: Appendix A - CADD Information Table
- Page 170 and 171: Appendix A - CADD Information Table
- Page 172 and 173: Appendix A - CADD Information Table
- Page 174 and 175: Appendix A - CADD Information Table
- Page 176 and 177: Appendix A - CADD Information Table
- Page 178 and 179: Appendix A - CADD Information Table
- Page 180 and 181: Appendix A - CADD Information Table
- Page 182 and 183: Appendix A - CADD Information Table
- Page 184 and 185: Appendix A - CADD Information Table
- Page 186 and 187: Appendix A - CADD Information Table
Appendix A – <strong>CADD</strong> Information Table Revised January 20, 2012<br />
By Level Attributes<br />
Level Name Description<br />
DR_X_Headwall (cont’d)<br />
CELLS PLACED ON LEVEL DR_X_Headwall (cont’d):<br />
Color<br />
Style<br />
DR – DRAINAGE – EXISTING (cont’d):<br />
Weight<br />
Transparency<br />
Priority<br />
Cell Name Cell Library Name<br />
Head Wall No. 1.1, 30° for 54" Pipe - - - 0 -100 HW1.1-30-54-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 30° for 60" Pipe - - - 0 -100 HW1.1-30-60-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 30° for 72" Pipe - - - 0 -100 HW1.1-30-72-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 30° for 84" Pipe - - - 0 -100 HW1.1-30-84-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1 for 42" Pipe - - - 0 -100 HW1.1-42-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 45° for 42" Pipe - - - 0 -100 HW1.1-45-42-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 45° for 48" Pipe - - - 0 -100 HW1.1-45-48-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 45° for 54" Pipe - - - 0 -100 HW1.1-45-54-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 45° for 60" Pipe - - - 0 -100 HW1.1-45-60-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 45° for 72" Pipe - - - 0 -100 HW1.1-45-72-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 45° for 84" Pipe - - - 0 -100 HW1.1-45-84-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1 for 48" Pipe - - - 0 -100 HW1.1-48-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1 for 54" Pipe - - - 0 -100 HW1.1-54-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1 for 60" Pipe - - - 0 -100 HW1.1-60-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1 for 72" Pipe - - - 0 -100 HW1.1-72-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1 for 84" Pipe - - - 0 -100 HW1.1-84-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 012" CMP - - - 0 -100 HW2.1-12-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 015" CMP - - - 0 -100 HW2.1-15-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 018" CMP - - - 0 -100 HW2.1-18-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 021" CMP - - - 0 -100 HW2.1-21-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 024" CMP - - - 0 -100 HW2.1-24-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 027" CMP - - - 0 -100 HW2.1-27-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 030" CMP - - - 0 -100 HW2.1-30-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 033" CMP - - - 0 -100 HW2.1-33-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 036" CMP - - - 0 -100 HW2.1-36-X ODOT_Drainage.cel P<br />
Head Wall No. 2.1 for 039" CMP - - - 0 -100 HW2.1-39-X ODOT_Drainage.cel P<br />
C = Cosmetic<br />
P = Physical<br />
Levels Do Not<br />
Plot<br />
NOTE: * Indicates Not By Level Page 20 <strong>of</strong> 108