Appendix A – <strong>CADD</strong> Information Table Revised January 20, 2012<br />
By Level Attributes<br />
Level Name Description<br />
DR_X_Erosion_Control<br />
Erosion Control Outline for RipRap, Rock<br />
Channel Protection and Jute Matting<br />
Color<br />
Style<br />
DR – DRAINAGE – EXISTING (cont’d):<br />
0 1 0 0 -100<br />
AREA PATTERNING CELLS TO BE PLACED ON LEVEL DR_X_Erosion_Control:<br />
Jute Matting<br />
(use Cross-Hatch Pattern tool)<br />
Rock Channel Protection<br />
(Pattern Cell)<br />
- - - 0 -100<br />
Weight<br />
Transparency<br />
Priority<br />
Cell Name Cell Library Name<br />
- - - 0 -100 RCP ODOT-Symbols.cel C<br />
Rip Rap (Pattern Cell) - - - 0 -100 RIPRAP ODOT-Symbols.cel C<br />
DR_X_Flood_Boundary Flood Boundary 170 5 1 0 -100<br />
DR_X_Floodway Floodway 167 7 0 0 -100<br />
DR_X_Flow_Arrow<br />
DR_X_Headwall<br />
Drainage Flow Arrow Symbols 17 0 0 0 -100<br />
CELLS PLACED ON LEVEL DR_X_Flow_Arrow:<br />
Drainage Flow Arrow - - - 0 -100 DFL-X ODOT_Drainage.cel C<br />
Drainage Headwall Symbols 10 1 0 0 -100<br />
CELLS PLACED ON LEVEL DR_X_Headwall:<br />
Head Wall No. 1 for 15" RCP - - - 0 -100 HW1-15-X ODOT_Drainage.cel P<br />
Head Wall No. 1 for 18" RCP - - - 0 -100 HW1-18-X ODOT_Drainage.cel P<br />
Head Wall No. 1 for 21" RCP - - - 0 -100 HW1-21-X ODOT_Drainage.cel P<br />
Head Wall No. 1 for 24" RCP - - - 0 -100 HW1-24-X ODOT_Drainage.cel P<br />
Head Wall No. 1 for 30" RCP - - - 0 -100 HW1-30-X ODOT_Drainage.cel P<br />
Head Wall No. 1 for 36" RCP - - - 0 -100 HW1-36-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 15° for 42" Pipe - - - 0 -100 HW1.1-15-42-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 15° for 48" Pipe - - - 0 -100 HW1.1-15-48-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 15° for 54" Pipe - - - 0 -100 HW1.1-15-54-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 15° for 60" Pipe - - - 0 -100 HW1.1-15-60-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 15° for 72" Pipe - - - 0 -100 HW1.1-15-72-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 15° for 84" Pipe - - - 0 -100 HW1.1-15-84-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 30° for 42" Pipe - - - 0 -100 HW1.1-30-42-X ODOT_Drainage.cel P<br />
Head Wall No. 1.1, 30° for 48" Pipe - - - 0 -100 HW1.1-30-48-X ODOT_Drainage.cel P<br />
C = Cosmetic<br />
P = Physical<br />
Levels Do Not<br />
Plot<br />
NOTE: * Indicates Not By Level Page 19 <strong>of</strong> 108