Appendix A – <strong>CADD</strong> Information Table Revised January 20, 2012<br />
By Level Attributes<br />
Level Name Description<br />
Color<br />
Style<br />
BR – BRIDGE – PROPOSED (cont’d):<br />
Weight<br />
Transparency<br />
Priority<br />
Cell Name Cell Library Name<br />
BR_P_Sub_Centerline Substructure Centerline 4 bcenterline 0 0 100 C<br />
BR_P_Sub_Const_Joint Substructure Construction Joint 1 bconstruction 1 0 100 C<br />
BR_P_Sub_Deep_Centerline Substructure Deep Foundation Centerline 4 bcenterline 0 0 100 C<br />
BR_P_Sub_Deep_Const_Joint<br />
BR_P_Sub_Deep_Hidden<br />
BR_P_Sub_Deep_Object<br />
Substructure Deep Foundation Construction<br />
Joint<br />
Substructure Deep Foundation Hidden<br />
(H-Piles, Drilled Shafts, etc.)<br />
CELLS PLACED ON LEVEL BR_P_Sub_Deep_Hidden:<br />
1 bconstruction 1 0 100 C<br />
7 bhiddenpr 1 0 100 C<br />
12 inch Dia. Pile Battered - - - 0 100 PILE12B ODOT_Bridge.cel P<br />
12 inch Dia. Pile Not Battered - - - 0 100 PILE12NB ODOT_Bridge.cel P<br />
14 inch Dia. Pile Battered - - - 0 100 PILE14B ODOT_Bridge.cel P<br />
14 inch Dia. Pile Not Battered - - - 0 100 PILE14NB ODOT_Bridge.cel P<br />
16 inch Dia. Pile Battered - - - 0 100 PILE16B ODOT_Bridge.cel P<br />
16 inch Dia. Pile Not Battered - - - 0 100 PILE16NB ODOT_Bridge.cel P<br />
Substructure Deep Foundation Object<br />
(H-Piles, Drilled Shafts, etc.)<br />
7 0 2 0 100<br />
BR_P_Sub_Deep_Reinforcing Substructure Deep Foundation Reinforcing 6 brebarpr 1 0 100 C<br />
BR_P_Sub_Deep_Text<br />
Substructure Deep Foundation Text and<br />
Dimensions<br />
0 0 1 0 500<br />
BR_P_Sub_Foot_Centerline Substructure Footing Centerline 4 bcenterline 0 0 100 C<br />
BR_P_Sub_Foot_Const_Joint Substructure Footing Construction Joint 1 bconstruction 1 0 100 C<br />
BR_P_Sub_Foot_Hidden<br />
BR_P_Sub_Foot_Object<br />
Substructure Footing Hidden<br />
(Spreadfooting, Pile cap, etc)<br />
Substructure Footing Object (Spreadfooting,<br />
Pile cap, etc)<br />
0 bhiddenpr 1 0 100 C<br />
0 0 2 0 100<br />
BR_P_Sub_Foot_Reinforcing Substructure Footing Reinforcing 6 brebarpr 1 0 100 C<br />
BR_P_Sub_Foot_Text Substructure Footing Text and Dimensions 0 0 1 0 500<br />
BR_P_Sub_Hidden<br />
BR_P_Sub_Object<br />
Substructure Hidden<br />
(Abutment, Pier, Retaining wall)<br />
Substructure Object<br />
(Abutment, Pier, Retaining wall)<br />
3 bhiddenpr 1 0 100 C<br />
3 0 2 0 100<br />
C = Cosmetic<br />
P = Physical<br />
Levels Do Not<br />
Plot<br />
NOTE: * Indicates Not By Level Page 12 <strong>of</strong> 108