09.04.2013 Views

CADD Engineering Standards - Ohio Department of Transportation

CADD Engineering Standards - Ohio Department of Transportation

CADD Engineering Standards - Ohio Department of Transportation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix A – <strong>CADD</strong> Information Table Revised January 20, 2012<br />

By Level Attributes<br />

Level Name Description<br />

Color<br />

Style<br />

BR – BRIDGE – PROPOSED (cont’d):<br />

Weight<br />

Transparency<br />

Priority<br />

Cell Name Cell Library Name<br />

BR_P_Sub_Centerline Substructure Centerline 4 bcenterline 0 0 100 C<br />

BR_P_Sub_Const_Joint Substructure Construction Joint 1 bconstruction 1 0 100 C<br />

BR_P_Sub_Deep_Centerline Substructure Deep Foundation Centerline 4 bcenterline 0 0 100 C<br />

BR_P_Sub_Deep_Const_Joint<br />

BR_P_Sub_Deep_Hidden<br />

BR_P_Sub_Deep_Object<br />

Substructure Deep Foundation Construction<br />

Joint<br />

Substructure Deep Foundation Hidden<br />

(H-Piles, Drilled Shafts, etc.)<br />

CELLS PLACED ON LEVEL BR_P_Sub_Deep_Hidden:<br />

1 bconstruction 1 0 100 C<br />

7 bhiddenpr 1 0 100 C<br />

12 inch Dia. Pile Battered - - - 0 100 PILE12B ODOT_Bridge.cel P<br />

12 inch Dia. Pile Not Battered - - - 0 100 PILE12NB ODOT_Bridge.cel P<br />

14 inch Dia. Pile Battered - - - 0 100 PILE14B ODOT_Bridge.cel P<br />

14 inch Dia. Pile Not Battered - - - 0 100 PILE14NB ODOT_Bridge.cel P<br />

16 inch Dia. Pile Battered - - - 0 100 PILE16B ODOT_Bridge.cel P<br />

16 inch Dia. Pile Not Battered - - - 0 100 PILE16NB ODOT_Bridge.cel P<br />

Substructure Deep Foundation Object<br />

(H-Piles, Drilled Shafts, etc.)<br />

7 0 2 0 100<br />

BR_P_Sub_Deep_Reinforcing Substructure Deep Foundation Reinforcing 6 brebarpr 1 0 100 C<br />

BR_P_Sub_Deep_Text<br />

Substructure Deep Foundation Text and<br />

Dimensions<br />

0 0 1 0 500<br />

BR_P_Sub_Foot_Centerline Substructure Footing Centerline 4 bcenterline 0 0 100 C<br />

BR_P_Sub_Foot_Const_Joint Substructure Footing Construction Joint 1 bconstruction 1 0 100 C<br />

BR_P_Sub_Foot_Hidden<br />

BR_P_Sub_Foot_Object<br />

Substructure Footing Hidden<br />

(Spreadfooting, Pile cap, etc)<br />

Substructure Footing Object (Spreadfooting,<br />

Pile cap, etc)<br />

0 bhiddenpr 1 0 100 C<br />

0 0 2 0 100<br />

BR_P_Sub_Foot_Reinforcing Substructure Footing Reinforcing 6 brebarpr 1 0 100 C<br />

BR_P_Sub_Foot_Text Substructure Footing Text and Dimensions 0 0 1 0 500<br />

BR_P_Sub_Hidden<br />

BR_P_Sub_Object<br />

Substructure Hidden<br />

(Abutment, Pier, Retaining wall)<br />

Substructure Object<br />

(Abutment, Pier, Retaining wall)<br />

3 bhiddenpr 1 0 100 C<br />

3 0 2 0 100<br />

C = Cosmetic<br />

P = Physical<br />

Levels Do Not<br />

Plot<br />

NOTE: * Indicates Not By Level Page 12 <strong>of</strong> 108

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!