05.04.2013 Views

Tennis court 24x12m - 300 Lux

Tennis court 24x12m - 300 Lux

Tennis court 24x12m - 300 Lux

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VIA ACHILLE GRANDI, 32 - 25125 BRESCIA / ITALY<br />

TEL. +39 030 26858.11 r.a. E-MAIL:lanzini @lanzini.it<br />

FAX +39 030 26858.35/79 INTERNET http://www:lanzini.it<br />

Lanzini propose a few lighting solutions for sporting facilities:<br />

<strong>Tennis</strong> <strong>court</strong> - <strong>24x12m</strong> - Level B page 2<br />

Five-a-side Football Field - 34x18m - Level C page 31<br />

Football Field - 100x60m - Level C page 4 1<br />

Football Field - 90x51m - Level C page 51<br />

Football Field - 100x68m - Level B page 61<br />

Football Field - 100x60m - Level A page 7 16<br />

Lighting levels recommended by CONI for outdoor sporting facilities:<br />

A – 500 <strong>Lux</strong> for matches very well attended by the public<br />

B – <strong>300</strong> <strong>Lux</strong> for amateur level matches with reduced public<br />

C – 100 <strong>Lux</strong> for recreational matches, training, without public<br />

As per UEFA recommendations, the lighting results of a football field must be detected in 77<br />

equidistant points at 10 m each other, starting from the middle of the field: the average values<br />

detected represent the average illumination over the horizontal plane (measured at 20cm from<br />

the ground). For TV transmissions, if possible, 1500 <strong>Lux</strong> should be achieved (unevenness 0.7).


Object<br />

Installation<br />

Project number<br />

Date :<br />

1. Project description<br />

1.1 Floor plan<br />

<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date :<br />

: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

:<br />

3. Results artificial light<br />

3.1 Table, Illuminance, Reference plane No. 1<br />

[m]<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

:<br />

[m]<br />

16<br />

14<br />

12<br />

10<br />

Campo 7<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Ref. plane 1<br />

0 5 10 15 20 25 30 35<br />

[m]<br />

Lanzini & C. S.r.l.<br />

262 322 345 341 320 310 (259) 310 320 341 345 322 262<br />

278 355 397 388 350 335 334 335 350 388 397 355 278<br />

269 360 414 426 380 328 320 328 380 426 414 360 269<br />

263 361 424 [435] 398 325 298 325 398 435 424 361 263<br />

269 360 414 426 380 328 320 328 380 426 414 360 269<br />

278<br />

355<br />

262 322<br />

Height of the reference plane : 0.80 m<br />

Average illuminance Eav : 355 lx<br />

Minimum illuminance Emin : 259 lx<br />

Maximum illuminance Emax : 435 lx<br />

Uniformity g1 Emin/Em : 1 : 1.37 (0.73)<br />

Uniformity g2 Emin/Emax : 1 : 1.68 (0.60)<br />

<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />

397<br />

345<br />

388<br />

341<br />

350<br />

320<br />

335<br />

310<br />

334<br />

259<br />

0 2 4 6 8 10 12 14 16 18 20 22<br />

[m]<br />

Illuminance [lx]<br />

335<br />

310<br />

350<br />

320<br />

388<br />

341<br />

397<br />

345<br />

355<br />

322<br />

278<br />

262<br />

Lanzini & C. S.r.l.<br />

N<br />

Page 1/4<br />

Page 3/4<br />

Object<br />

Installation<br />

Project number<br />

Date :<br />

2. Summary<br />

: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

:<br />

2.1 Result overview, Reference plane No. 1<br />

<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />

[m]<br />

16<br />

0<br />

0 15 35 [m]<br />

200 250 <strong>300</strong> 500 750<br />

Illuminance [lx]<br />

General<br />

Calculation algorithm used Direct part<br />

Maintenance factor 0.80<br />

Height of evaluation area 0.80 m<br />

Light spot height. [m]: 9.00 m<br />

Total luminous flux of all lamps 560000 lm<br />

Total power 6400 W<br />

Total power per area (600.60 m²) 10.66 W/m²<br />

Illuminance<br />

Average illuminance Eav 355 lx<br />

Minimum illuminance Emin 259 lx<br />

Maximum illuminance Emax 435 lx<br />

Uniformity g1 Emin/Em 1:1.37 (0.73)<br />

Uniformity g2<br />

Type No.\Manuf.<br />

Lanzini<br />

Emin/Emax 1:1.68 (0.6)<br />

1 16 Order no. : 26106<br />

Luminaire name : Olympia 2 Diff. Grigio<br />

Equipment : 1 x HIT 400 W / 35000 lm<br />

Object<br />

Installation<br />

Project number<br />

Date :<br />

: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />

:<br />

3.2 3D luminance distribution, Variable view<br />

Luminance on the room-surrounding surfaces:<br />

Minimum:: 16.5 cd/m²<br />

Maximum:: 80.7 cd/m²<br />

<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

N<br />

Page 2/4<br />

Page 4/4


Object<br />

Installation<br />

Project number<br />

Date : 17.06.2003<br />

1. Project description<br />

1.1 Floor plan<br />

Football field 34x18m- 150 <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date : 17.06.2003<br />

: Lighting football field 34x18m<br />

: Football field 34x18m<br />

:<br />

: Lighting football field 34x18m<br />

: Football field 34x18m<br />

:<br />

3. Results artificial light<br />

3.1 Table, Illuminance, Reference plane No. 1<br />

[m]<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

98 156 144 101 105 117 105 101 144 156<br />

120 [200] 170 163 158 133 158 163 170 [200] 120<br />

98 156<br />

Height of the reference plane : 0.20 m<br />

Average illuminance Eav : 152 lx<br />

Minimum illuminance Emin : 98 lx<br />

Maximum illuminance Emax : 200 lx<br />

Uniformity g1 Emin/Em : 1 : 1.55 (0.65)<br />

Uniformity g2 Emin/Emax : 1 : 2.03 (0.49)<br />

Football field 34x18m- 150 <strong>Lux</strong><br />

144<br />

101 105<br />

117<br />

105<br />

[m]<br />

25.0<br />

2.1 2.2 2.3<br />

4.1 4.2 4.3<br />

20.0<br />

15.0<br />

10.0<br />

Football field 34x18m<br />

Ref. plane 1<br />

5.0<br />

1.1 1.2 1.3<br />

3.1 3.2 3.3<br />

0.0<br />

0 5 10 15 20 25 30 35 40<br />

[m]<br />

101 144<br />

(98)<br />

120 200 170 163 158 133 158 163 170 200 120<br />

110 178 181 179 141 117 141 179 181 178 110<br />

102 160 164 183 131 112 131 183 164 160 102<br />

110 178 181 179 141 117 141 179 181 178 110<br />

156 98<br />

0 5 10 15 20 25 30<br />

[m]<br />

Illuminance [lx]<br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

N<br />

Page 1/4<br />

Page 3/4<br />

Object<br />

Installation<br />

Project number<br />

Date : 17.06.2003<br />

2. Summary<br />

: Lighting football field 34x18m<br />

: Football field 34x18m<br />

:<br />

2.1 Result overview, Reference plane No. 1<br />

Football field 34x18m- 150 <strong>Lux</strong><br />

N<br />

[m]<br />

25.0<br />

2.1 2.2 2.34.1<br />

4.2 4.3<br />

0.0 1.1 1.2 1.33.1<br />

3.2 3.3<br />

0 20<br />

[m]<br />

75 100 150 200 250<br />

Illuminance [lx]<br />

General<br />

Calculation algorithm used Direct part<br />

Maintenance factor 0.80<br />

Height of evaluation area 0.20 m<br />

Light spot height. [m]: 6.00 m<br />

Total luminous flux of all lamps 420000 lm<br />

Total power 4800 W<br />

Total power per area (1232.00 m²) 3.90 W/m²<br />

Illuminance<br />

Average illuminance Eav 152 lx<br />

Minimum illuminance Emin 98 lx<br />

Maximum illuminance Emax 200 lx<br />

Uniformity g1 Emin/Em 1:1.55 (0.65)<br />

Uniformity g2<br />

Type No.\Manuf.<br />

Lanzini<br />

Emin/Emax 1:2.03 (0.49)<br />

1 12 Order no. : 20431<br />

Luminaire name : Raggio 2 Diff. Grigio<br />

Equipment : 1 x HIT 400 W / 35000 lm<br />

Object<br />

Installation<br />

Project number<br />

Date : 17.06.2003<br />

: Lighting football field 34x18m<br />

: Football field 34x18m<br />

:<br />

3.2 3D luminance distribution, Variable view<br />

Luminance on the room-surrounding surfaces:<br />

Minimum:: 1.27 cd/m²<br />

Maximum:: 18.5 cd/m²<br />

Football field 34x18m- 150 <strong>Lux</strong><br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

Page 2/4<br />

Page 4/4


Object<br />

Installation<br />

Project number<br />

Date : 14.04.2003<br />

1. Project description<br />

1.1 Floor plan<br />

Football field 100x60m - 100 <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date : 14.04.2003<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

3. Results artificial light<br />

3.1 Table, Illuminance, Reference plane No. 1<br />

[m]<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

(66)<br />

102<br />

66 76<br />

Football field 100x60m - 100 <strong>Lux</strong><br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

76 114 148 73 91 91 73 148 114 76 66<br />

[m]<br />

70<br />

60<br />

50<br />

2.1 2.2 2.3<br />

4.1 4.2 4.3<br />

40<br />

Football field 100x60m<br />

30<br />

20<br />

10<br />

Ref. plane 1<br />

0<br />

0<br />

1.1 1.2 1.3<br />

3.1 3.2 3.3<br />

10 20 30 40 50 60 70 80 90 100<br />

102 128 125 119 107 123 123 107 119 125 128 102<br />

89 136 133 122 104 102 102 104 122 133 136 89<br />

70 107 127 127 102 75 75 102 127 127 107 70<br />

89 136 133 122 104 102 102 104 122 133 136 89<br />

128<br />

125<br />

114<br />

119<br />

148<br />

107<br />

73<br />

Height of the reference plane : 0.20 m<br />

Average illuminance Eav : 112 lx<br />

Minimum illuminance Emin : 66 lx<br />

Maximum illuminance Emax : 148 lx<br />

Uniformity g1 Emin/Em : 1 : 1.70 (0.59)<br />

Uniformity g2 Emin/Emax : 1 : 2.24 (0.45)<br />

123<br />

91<br />

123<br />

91<br />

107 119<br />

125<br />

73 [148] 114 76<br />

Lanzini & C. S.r.l.<br />

0 10 20 30 40 50 60 70 80 90 100<br />

[m]<br />

Illuminance [lx]<br />

128<br />

102<br />

66<br />

Lanzini & C. S.r.l.<br />

[m]<br />

N<br />

Page 1/4<br />

Page 3/4<br />

Object<br />

Installation<br />

Project number<br />

Date : 14.04.2003<br />

2. Summary<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

2.1 Result overview, Reference plane No. 1<br />

Football field 100x60m - 100 <strong>Lux</strong><br />

N<br />

[m]<br />

60 2.1 2.2 2.34.1<br />

4.2 4.3<br />

0<br />

1.1 1.2 1.33.1<br />

3.2 3.3<br />

0 50<br />

[m]<br />

30 50 75 100 150<br />

Illuminance [lx]<br />

General<br />

Calculation algorithm used Direct part<br />

Maintenance factor 0.80<br />

Height of evaluation area 0.20 m<br />

Light spot height. [m]: 18.00 m<br />

Total luminous flux of all lamps 2160000 lm<br />

Total power 24000 W<br />

Total power per area (7700.00 m²) 3.12 W/m²<br />

Illuminance<br />

Average illuminance Eav 112 lx<br />

Minimum illuminance Emin 66 lx<br />

Maximum illuminance Emax 148 lx<br />

Uniformity g1 Emin/Em 1:1.7 (0.59)<br />

Uniformity g2<br />

Type No.\Manuf.<br />

Lanzini<br />

Emin/Emax 1:2.24 (0.45)<br />

1 12 Order no. : 24738<br />

Luminaire name : Daytona Conc. Grigio 380V<br />

Equipment : 1 x HIT-I 2000 W / 180000 lm<br />

Object<br />

Installation<br />

Project number<br />

Date : 14.04.2003<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

3.2 3D luminance distribution, Variable view<br />

Luminance on the room-surrounding surfaces:<br />

Minimum:: 3.02 cd/m²<br />

Maximum:: 11.3 cd/m²<br />

Football field 100x60m - 100 <strong>Lux</strong><br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

Page 2/4<br />

Page 4/4


Object<br />

Installation<br />

Project number<br />

Date : 18.03.2003<br />

1. Project description<br />

1.1 Floor plan<br />

Football field 90x51m - 200 <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date : 18.03.2003<br />

: Lighting Football field 90x51m<br />

: Football field 90x51m<br />

:<br />

: Lighting Football field 90x51m<br />

: Football field 90x51m<br />

:<br />

3. Results artificial light<br />

3.1 Table, Illuminance, Reference plane No. 1<br />

[m]<br />

50<br />

185 (172) 302 176 225 213 225 176 302 172 185<br />

45<br />

40<br />

204 205 212 209 234 231 234 209 212 205 204<br />

35 176 240 227 234 227 212 227 234 227 240 176<br />

30<br />

25<br />

179 240 258 246 218 198 218 246 258 240 179<br />

20<br />

15<br />

176 240 227 234 227 212 227 234 227 240 176<br />

10 204 205 212 209 234 231 234 209 212 205 204<br />

5<br />

0<br />

185 172 [302] 176 225 213 225 176 302 172 185<br />

0 10 20 30 40 50 60 70 80 90<br />

[m]<br />

Illuminance [lx]<br />

Height of the reference plane : 0.20 m<br />

Average illuminance Eav : 221 lx<br />

Minimum illuminance Emin : 172 lx<br />

Maximum illuminance Emax : 302 lx<br />

Uniformity g1 Emin/Em : 1 : 1.29 (0.78)<br />

Uniformity g2 Emin/Emax : 1 : 1.76 (0.57)<br />

Football field 90x51m - 200 <strong>Lux</strong><br />

N<br />

[m]<br />

60<br />

50<br />

40<br />

2.1 2.2 2.3 2.4 2.5<br />

4.3 4.4 4.5 4.1 4.2<br />

Football field 90x51m<br />

30<br />

20<br />

10<br />

Ref. plane 1<br />

0<br />

0 10<br />

1.1 1.2 1.3 1.4 1.5<br />

20 30 40 50 60<br />

3.3 3.4 3.5 3.1 3.2<br />

70 80 90 100<br />

[m]<br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

Page 1/4<br />

Page 3/4<br />

Object<br />

Installation<br />

Project number<br />

Date : 18.03.2003<br />

2. Summary<br />

: Lighting Football field 90x51m<br />

: Football field 90x51m<br />

:<br />

2.1 Result overview, Reference plane No. 1<br />

Football field 90x51m - 200 <strong>Lux</strong><br />

N<br />

[m]<br />

55<br />

2.2 2.3 2.4 2.5 2.14.1<br />

4.2 4.3 4.4 4.5<br />

0<br />

1.2 1.3 1.4 1.5 1.13.1<br />

3.2 3.3 3.4 3.5<br />

0 40<br />

[m]<br />

100 150 200 250 <strong>300</strong><br />

Illuminance [lx]<br />

General<br />

Calculation algorithm used Direct part<br />

Maintenance factor 0.80<br />

Height of evaluation area 0.20 m<br />

Light spot height. [m]: 18.00 m<br />

Total luminous flux of all lamps 3600000 lm<br />

Total power 40000 W<br />

Total power per area (6100.00 m²) 6.56 W/m²<br />

Illuminance<br />

Average illuminance Eav 221 lx<br />

Minimum illuminance Emin 172 lx<br />

Maximum illuminance Emax 302 lx<br />

Uniformity g1 Emin/Em 1:1.29 (0.78)<br />

Uniformity g2<br />

Type No.\Manuf.<br />

Lanzini<br />

Emin/Emax 1:1.76 (0.57)<br />

1 20 Order no. : 24738<br />

Luminaire name : Daytona Conc. Grigio 380V<br />

Equipment : 1 x HIT-I 2000 W / 180000 lm<br />

Object<br />

Installation<br />

Project number<br />

Date : 18.03.2003<br />

: Lighting Football field 90x51m<br />

: Football field 90x51m<br />

:<br />

3.2 3D luminance distribution, Variable view<br />

Luminance on the room-surrounding surfaces:<br />

Minimum:: 6.54 cd/m²<br />

Maximum:: 16.1 cd/m²<br />

Football field 90x51m - 200 <strong>Lux</strong><br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

Page 2/4<br />

Page 4/4


Object<br />

Installation<br />

Project number<br />

Date : 15.12.2003<br />

1. Project description<br />

1.1 Floor plan<br />

Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date : 15.12.2003<br />

: Lighting Foorball field 100x68m<br />

: Football field 100x68m<br />

:<br />

3. Results artificial light<br />

3.1 Table, Illuminance, Reference plane No. 1<br />

[m]<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

: Lighting Foorball field 100x68m<br />

: Football field 100x68m<br />

:<br />

221 277 338 268 229 239 229 268 338 277 221<br />

275 348 307 <strong>300</strong> 290 274 290 <strong>300</strong> 307 348 275<br />

255 344 349 326 294 259 294 326 [349] 344 255<br />

218 308 340 324 278 249 278 324 340 308<br />

Height of the reference plane : 0.20 m<br />

Average illuminance Eav : <strong>300</strong> lx<br />

Minimum illuminance Emin : 218 lx<br />

Maximum illuminance Emax : 349 lx<br />

Uniformity g1 Emin/Em : 1 : 1.38 (0.73)<br />

Uniformity g2 Emin/Emax : 1 : 1.60 (0.63)<br />

Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />

N<br />

[m]<br />

80<br />

70<br />

60<br />

2.10 2.2 2.3 2.4 2.6 2.7 2.8 2.9 2.1 2.5<br />

4.10 4.2 4.3 4.4 4.6 4.9 4.1 4.5 4.7 4.8<br />

50<br />

Football field 100x68m<br />

40<br />

30<br />

20<br />

10<br />

Ref. plane 1<br />

0<br />

0 10<br />

1.10 1.2 1.3 1.4 1.6 1.7 1.8 1.9 1.1 1.5<br />

30 50 70<br />

3.10 3.2 3.3 3.4 3.6 3.9 3.1 3.5 3.7 3.8<br />

90 110<br />

[m]<br />

(218)<br />

255 344 349 326 294 259 294 326 349 344 255<br />

275<br />

348<br />

221 277<br />

307<br />

338<br />

<strong>300</strong><br />

268<br />

290<br />

229<br />

274<br />

239<br />

290<br />

229<br />

<strong>300</strong><br />

268<br />

307<br />

338<br />

348<br />

277<br />

275<br />

221<br />

0 10 20 30 40 50 60 70 80 90 100<br />

[m]<br />

Illuminance [lx]<br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

Page 1/4<br />

Page 3/4<br />

Object<br />

Installation<br />

Project number<br />

Date : 15.12.2003<br />

2. Summary<br />

: Lighting Foorball field 100x68m<br />

: Football field 100x68m<br />

:<br />

2.1 Result overview, Reference plane No. 1<br />

Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />

N<br />

[m]<br />

80<br />

2.10 2.5 2.1 2.2 2.3 2.4 2.6 2.7 2.8 2.94.10<br />

4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9<br />

0<br />

1.10 1.5 1.1 1.2 1.3 1.4 1.6 1.7 1.8 1.93.10<br />

3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9<br />

0 60<br />

[m]<br />

150 200 250 <strong>300</strong> 500<br />

Illuminance [lx]<br />

General<br />

Calculation algorithm used Direct part<br />

Maintenance factor 0.80<br />

Height of evaluation area 0.20 m<br />

Light spot height. [m]: 23.00 m<br />

Total luminous flux of all lamps 7200000 lm<br />

Total power 80000 W<br />

Total power per area (10560.00 m²) 7.58 W/m²<br />

Illuminance<br />

Average illuminance Eav <strong>300</strong> lx<br />

Minimum illuminance Emin 218 lx<br />

Maximum illuminance Emax 349 lx<br />

Uniformity g1 Emin/Em 1:1.38 (0.73)<br />

Uniformity g2<br />

Type No.\Manuf.<br />

Lanzini<br />

Emin/Emax 1:1.6 (0.63)<br />

1 40 Order no. : 24738<br />

Luminaire name : Daytona Conc. Grigio 380V<br />

Equipment : 1 x HIT-I 2000 W / 180000 lm<br />

Object<br />

Installation<br />

Project number<br />

Date : 15.12.2003<br />

: Lighting Foorball field 100x68m<br />

: Football field 100x68m<br />

:<br />

3.2 3D luminance distribution, Variable view<br />

Luminance on the room-surrounding surfaces:<br />

Minimum:: 4.09 cd/m²<br />

Maximum:: 18.9 cd/m²<br />

Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

Page 2/4<br />

Page 4/4


Object<br />

Installation<br />

Project number<br />

Date : 23.05.2001<br />

1. Project description<br />

1.1 Floor plan<br />

Football field 100x60m - 500 <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date : 23.05.2001<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

3. Results artificial light<br />

[m]<br />

60<br />

40<br />

20<br />

0<br />

3.1 Table, Illuminance, Reference plane No. 1<br />

[m]<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

438 423 449 460 456 456 456 460 449 423 438<br />

458 520 592 567 538 525 538 567 592 520 458<br />

483 632 650 639 591 557 591 639 650 632 483<br />

517 631 [676] 666 603 563 603 666 676 631 517<br />

483 632 650 639 591 557 591 639 650 632 483<br />

458<br />

520<br />

438 423<br />

Height of the reference plane : 0.20 m<br />

Average illuminance Eav : 561 lx<br />

Minimum illuminance Emin : 423 lx<br />

Maximum illuminance Emax : 676 lx<br />

Uniformity g1 Emin/Em : 1 : 1.33 (0.75)<br />

Uniformity g2 Emin/Emax : 1 : 1.60 (0.63)<br />

Football field 100x60m - 500 <strong>Lux</strong><br />

592<br />

449<br />

567<br />

460<br />

538<br />

456<br />

525<br />

456<br />

538<br />

456<br />

567<br />

592 520<br />

460 449 (423) 438<br />

Football field 100x68m<br />

Ref. plane 1<br />

0 20 40 60 80 100 120 [m]<br />

1 : 2500<br />

458<br />

0 10 20 30 40 50 60 70 80 90 100<br />

[m]<br />

Illuminance [lx]<br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

N<br />

Page 1/4<br />

Page 3/4<br />

Object<br />

Installation<br />

Project number<br />

Date : 23.05.2001<br />

2. Summary<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

2.1 Result overview, Reference plane No. 1<br />

250 <strong>300</strong> 500 750 1000<br />

Illuminance [lx]<br />

General<br />

Calculation algorithm used Direct part<br />

Maintenance factor 0.80<br />

Height of evaluation area 0.20 m<br />

Light spot height. [m]: 35.00 m<br />

Total luminous flux of all lamps 16000000 lm<br />

Total power 160000 W<br />

Total power per area (9485.32 m²) 16.87 W/m²<br />

Illuminance<br />

Average illuminance Eav 561 lx<br />

Minimum illuminance Emin 423 lx<br />

Maximum illuminance Emax 676 lx<br />

Uniformity g1 Emin/Em 1:1.33 (0.75)<br />

Uniformity g2<br />

Type No.\Manuf.<br />

Lanzini<br />

Emin/Emax 1:1.6 (0.63)<br />

1 80 Order no. : 24741<br />

Luminaire name : Daytona Conc. Grigio 380V<br />

Equipment : 1 x HIT-I 2000 W / 200000 lm<br />

Football field 100x60m - 500 <strong>Lux</strong><br />

Object<br />

Installation<br />

Project number<br />

Date : 23.05.2001<br />

: Lighting Football field 100x60m<br />

: Football field 100x60m<br />

:<br />

3.2 3D luminance distribution, Variable view<br />

Luminance on the room-surrounding surfaces:<br />

Minimum:: 17.2 cd/m²<br />

Maximum:: 71.3 cd/m²<br />

Football field 100x60m - 500 <strong>Lux</strong><br />

[m]<br />

70<br />

0<br />

0 60<br />

[m]<br />

Lanzini & C. S.r.l.<br />

Lanzini & C. S.r.l.<br />

N<br />

Page 2/4<br />

Page 4/4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!