Tennis court 24x12m - 300 Lux
Tennis court 24x12m - 300 Lux
Tennis court 24x12m - 300 Lux
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
VIA ACHILLE GRANDI, 32 - 25125 BRESCIA / ITALY<br />
TEL. +39 030 26858.11 r.a. E-MAIL:lanzini @lanzini.it<br />
FAX +39 030 26858.35/79 INTERNET http://www:lanzini.it<br />
Lanzini propose a few lighting solutions for sporting facilities:<br />
<strong>Tennis</strong> <strong>court</strong> - <strong>24x12m</strong> - Level B page 2<br />
Five-a-side Football Field - 34x18m - Level C page 31<br />
Football Field - 100x60m - Level C page 4 1<br />
Football Field - 90x51m - Level C page 51<br />
Football Field - 100x68m - Level B page 61<br />
Football Field - 100x60m - Level A page 7 16<br />
Lighting levels recommended by CONI for outdoor sporting facilities:<br />
A – 500 <strong>Lux</strong> for matches very well attended by the public<br />
B – <strong>300</strong> <strong>Lux</strong> for amateur level matches with reduced public<br />
C – 100 <strong>Lux</strong> for recreational matches, training, without public<br />
As per UEFA recommendations, the lighting results of a football field must be detected in 77<br />
equidistant points at 10 m each other, starting from the middle of the field: the average values<br />
detected represent the average illumination over the horizontal plane (measured at 20cm from<br />
the ground). For TV transmissions, if possible, 1500 <strong>Lux</strong> should be achieved (unevenness 0.7).
Object<br />
Installation<br />
Project number<br />
Date :<br />
1. Project description<br />
1.1 Floor plan<br />
<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date :<br />
: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
:<br />
3. Results artificial light<br />
3.1 Table, Illuminance, Reference plane No. 1<br />
[m]<br />
10<br />
8<br />
6<br />
4<br />
2<br />
0<br />
: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
:<br />
[m]<br />
16<br />
14<br />
12<br />
10<br />
Campo 7<br />
8<br />
6<br />
4<br />
2<br />
0<br />
Ref. plane 1<br />
0 5 10 15 20 25 30 35<br />
[m]<br />
Lanzini & C. S.r.l.<br />
262 322 345 341 320 310 (259) 310 320 341 345 322 262<br />
278 355 397 388 350 335 334 335 350 388 397 355 278<br />
269 360 414 426 380 328 320 328 380 426 414 360 269<br />
263 361 424 [435] 398 325 298 325 398 435 424 361 263<br />
269 360 414 426 380 328 320 328 380 426 414 360 269<br />
278<br />
355<br />
262 322<br />
Height of the reference plane : 0.80 m<br />
Average illuminance Eav : 355 lx<br />
Minimum illuminance Emin : 259 lx<br />
Maximum illuminance Emax : 435 lx<br />
Uniformity g1 Emin/Em : 1 : 1.37 (0.73)<br />
Uniformity g2 Emin/Emax : 1 : 1.68 (0.60)<br />
<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />
397<br />
345<br />
388<br />
341<br />
350<br />
320<br />
335<br />
310<br />
334<br />
259<br />
0 2 4 6 8 10 12 14 16 18 20 22<br />
[m]<br />
Illuminance [lx]<br />
335<br />
310<br />
350<br />
320<br />
388<br />
341<br />
397<br />
345<br />
355<br />
322<br />
278<br />
262<br />
Lanzini & C. S.r.l.<br />
N<br />
Page 1/4<br />
Page 3/4<br />
Object<br />
Installation<br />
Project number<br />
Date :<br />
2. Summary<br />
: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
:<br />
2.1 Result overview, Reference plane No. 1<br />
<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />
[m]<br />
16<br />
0<br />
0 15 35 [m]<br />
200 250 <strong>300</strong> 500 750<br />
Illuminance [lx]<br />
General<br />
Calculation algorithm used Direct part<br />
Maintenance factor 0.80<br />
Height of evaluation area 0.80 m<br />
Light spot height. [m]: 9.00 m<br />
Total luminous flux of all lamps 560000 lm<br />
Total power 6400 W<br />
Total power per area (600.60 m²) 10.66 W/m²<br />
Illuminance<br />
Average illuminance Eav 355 lx<br />
Minimum illuminance Emin 259 lx<br />
Maximum illuminance Emax 435 lx<br />
Uniformity g1 Emin/Em 1:1.37 (0.73)<br />
Uniformity g2<br />
Type No.\Manuf.<br />
Lanzini<br />
Emin/Emax 1:1.68 (0.6)<br />
1 16 Order no. : 26106<br />
Luminaire name : Olympia 2 Diff. Grigio<br />
Equipment : 1 x HIT 400 W / 35000 lm<br />
Object<br />
Installation<br />
Project number<br />
Date :<br />
: Lighting <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
: <strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong><br />
:<br />
3.2 3D luminance distribution, Variable view<br />
Luminance on the room-surrounding surfaces:<br />
Minimum:: 16.5 cd/m²<br />
Maximum:: 80.7 cd/m²<br />
<strong>Tennis</strong> <strong>court</strong> <strong>24x12m</strong> - <strong>300</strong> <strong>Lux</strong><br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
N<br />
Page 2/4<br />
Page 4/4
Object<br />
Installation<br />
Project number<br />
Date : 17.06.2003<br />
1. Project description<br />
1.1 Floor plan<br />
Football field 34x18m- 150 <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date : 17.06.2003<br />
: Lighting football field 34x18m<br />
: Football field 34x18m<br />
:<br />
: Lighting football field 34x18m<br />
: Football field 34x18m<br />
:<br />
3. Results artificial light<br />
3.1 Table, Illuminance, Reference plane No. 1<br />
[m]<br />
18<br />
16<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
0<br />
98 156 144 101 105 117 105 101 144 156<br />
120 [200] 170 163 158 133 158 163 170 [200] 120<br />
98 156<br />
Height of the reference plane : 0.20 m<br />
Average illuminance Eav : 152 lx<br />
Minimum illuminance Emin : 98 lx<br />
Maximum illuminance Emax : 200 lx<br />
Uniformity g1 Emin/Em : 1 : 1.55 (0.65)<br />
Uniformity g2 Emin/Emax : 1 : 2.03 (0.49)<br />
Football field 34x18m- 150 <strong>Lux</strong><br />
144<br />
101 105<br />
117<br />
105<br />
[m]<br />
25.0<br />
2.1 2.2 2.3<br />
4.1 4.2 4.3<br />
20.0<br />
15.0<br />
10.0<br />
Football field 34x18m<br />
Ref. plane 1<br />
5.0<br />
1.1 1.2 1.3<br />
3.1 3.2 3.3<br />
0.0<br />
0 5 10 15 20 25 30 35 40<br />
[m]<br />
101 144<br />
(98)<br />
120 200 170 163 158 133 158 163 170 200 120<br />
110 178 181 179 141 117 141 179 181 178 110<br />
102 160 164 183 131 112 131 183 164 160 102<br />
110 178 181 179 141 117 141 179 181 178 110<br />
156 98<br />
0 5 10 15 20 25 30<br />
[m]<br />
Illuminance [lx]<br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
N<br />
Page 1/4<br />
Page 3/4<br />
Object<br />
Installation<br />
Project number<br />
Date : 17.06.2003<br />
2. Summary<br />
: Lighting football field 34x18m<br />
: Football field 34x18m<br />
:<br />
2.1 Result overview, Reference plane No. 1<br />
Football field 34x18m- 150 <strong>Lux</strong><br />
N<br />
[m]<br />
25.0<br />
2.1 2.2 2.34.1<br />
4.2 4.3<br />
0.0 1.1 1.2 1.33.1<br />
3.2 3.3<br />
0 20<br />
[m]<br />
75 100 150 200 250<br />
Illuminance [lx]<br />
General<br />
Calculation algorithm used Direct part<br />
Maintenance factor 0.80<br />
Height of evaluation area 0.20 m<br />
Light spot height. [m]: 6.00 m<br />
Total luminous flux of all lamps 420000 lm<br />
Total power 4800 W<br />
Total power per area (1232.00 m²) 3.90 W/m²<br />
Illuminance<br />
Average illuminance Eav 152 lx<br />
Minimum illuminance Emin 98 lx<br />
Maximum illuminance Emax 200 lx<br />
Uniformity g1 Emin/Em 1:1.55 (0.65)<br />
Uniformity g2<br />
Type No.\Manuf.<br />
Lanzini<br />
Emin/Emax 1:2.03 (0.49)<br />
1 12 Order no. : 20431<br />
Luminaire name : Raggio 2 Diff. Grigio<br />
Equipment : 1 x HIT 400 W / 35000 lm<br />
Object<br />
Installation<br />
Project number<br />
Date : 17.06.2003<br />
: Lighting football field 34x18m<br />
: Football field 34x18m<br />
:<br />
3.2 3D luminance distribution, Variable view<br />
Luminance on the room-surrounding surfaces:<br />
Minimum:: 1.27 cd/m²<br />
Maximum:: 18.5 cd/m²<br />
Football field 34x18m- 150 <strong>Lux</strong><br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
Page 2/4<br />
Page 4/4
Object<br />
Installation<br />
Project number<br />
Date : 14.04.2003<br />
1. Project description<br />
1.1 Floor plan<br />
Football field 100x60m - 100 <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date : 14.04.2003<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
3. Results artificial light<br />
3.1 Table, Illuminance, Reference plane No. 1<br />
[m]<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
(66)<br />
102<br />
66 76<br />
Football field 100x60m - 100 <strong>Lux</strong><br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
76 114 148 73 91 91 73 148 114 76 66<br />
[m]<br />
70<br />
60<br />
50<br />
2.1 2.2 2.3<br />
4.1 4.2 4.3<br />
40<br />
Football field 100x60m<br />
30<br />
20<br />
10<br />
Ref. plane 1<br />
0<br />
0<br />
1.1 1.2 1.3<br />
3.1 3.2 3.3<br />
10 20 30 40 50 60 70 80 90 100<br />
102 128 125 119 107 123 123 107 119 125 128 102<br />
89 136 133 122 104 102 102 104 122 133 136 89<br />
70 107 127 127 102 75 75 102 127 127 107 70<br />
89 136 133 122 104 102 102 104 122 133 136 89<br />
128<br />
125<br />
114<br />
119<br />
148<br />
107<br />
73<br />
Height of the reference plane : 0.20 m<br />
Average illuminance Eav : 112 lx<br />
Minimum illuminance Emin : 66 lx<br />
Maximum illuminance Emax : 148 lx<br />
Uniformity g1 Emin/Em : 1 : 1.70 (0.59)<br />
Uniformity g2 Emin/Emax : 1 : 2.24 (0.45)<br />
123<br />
91<br />
123<br />
91<br />
107 119<br />
125<br />
73 [148] 114 76<br />
Lanzini & C. S.r.l.<br />
0 10 20 30 40 50 60 70 80 90 100<br />
[m]<br />
Illuminance [lx]<br />
128<br />
102<br />
66<br />
Lanzini & C. S.r.l.<br />
[m]<br />
N<br />
Page 1/4<br />
Page 3/4<br />
Object<br />
Installation<br />
Project number<br />
Date : 14.04.2003<br />
2. Summary<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
2.1 Result overview, Reference plane No. 1<br />
Football field 100x60m - 100 <strong>Lux</strong><br />
N<br />
[m]<br />
60 2.1 2.2 2.34.1<br />
4.2 4.3<br />
0<br />
1.1 1.2 1.33.1<br />
3.2 3.3<br />
0 50<br />
[m]<br />
30 50 75 100 150<br />
Illuminance [lx]<br />
General<br />
Calculation algorithm used Direct part<br />
Maintenance factor 0.80<br />
Height of evaluation area 0.20 m<br />
Light spot height. [m]: 18.00 m<br />
Total luminous flux of all lamps 2160000 lm<br />
Total power 24000 W<br />
Total power per area (7700.00 m²) 3.12 W/m²<br />
Illuminance<br />
Average illuminance Eav 112 lx<br />
Minimum illuminance Emin 66 lx<br />
Maximum illuminance Emax 148 lx<br />
Uniformity g1 Emin/Em 1:1.7 (0.59)<br />
Uniformity g2<br />
Type No.\Manuf.<br />
Lanzini<br />
Emin/Emax 1:2.24 (0.45)<br />
1 12 Order no. : 24738<br />
Luminaire name : Daytona Conc. Grigio 380V<br />
Equipment : 1 x HIT-I 2000 W / 180000 lm<br />
Object<br />
Installation<br />
Project number<br />
Date : 14.04.2003<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
3.2 3D luminance distribution, Variable view<br />
Luminance on the room-surrounding surfaces:<br />
Minimum:: 3.02 cd/m²<br />
Maximum:: 11.3 cd/m²<br />
Football field 100x60m - 100 <strong>Lux</strong><br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
Page 2/4<br />
Page 4/4
Object<br />
Installation<br />
Project number<br />
Date : 18.03.2003<br />
1. Project description<br />
1.1 Floor plan<br />
Football field 90x51m - 200 <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date : 18.03.2003<br />
: Lighting Football field 90x51m<br />
: Football field 90x51m<br />
:<br />
: Lighting Football field 90x51m<br />
: Football field 90x51m<br />
:<br />
3. Results artificial light<br />
3.1 Table, Illuminance, Reference plane No. 1<br />
[m]<br />
50<br />
185 (172) 302 176 225 213 225 176 302 172 185<br />
45<br />
40<br />
204 205 212 209 234 231 234 209 212 205 204<br />
35 176 240 227 234 227 212 227 234 227 240 176<br />
30<br />
25<br />
179 240 258 246 218 198 218 246 258 240 179<br />
20<br />
15<br />
176 240 227 234 227 212 227 234 227 240 176<br />
10 204 205 212 209 234 231 234 209 212 205 204<br />
5<br />
0<br />
185 172 [302] 176 225 213 225 176 302 172 185<br />
0 10 20 30 40 50 60 70 80 90<br />
[m]<br />
Illuminance [lx]<br />
Height of the reference plane : 0.20 m<br />
Average illuminance Eav : 221 lx<br />
Minimum illuminance Emin : 172 lx<br />
Maximum illuminance Emax : 302 lx<br />
Uniformity g1 Emin/Em : 1 : 1.29 (0.78)<br />
Uniformity g2 Emin/Emax : 1 : 1.76 (0.57)<br />
Football field 90x51m - 200 <strong>Lux</strong><br />
N<br />
[m]<br />
60<br />
50<br />
40<br />
2.1 2.2 2.3 2.4 2.5<br />
4.3 4.4 4.5 4.1 4.2<br />
Football field 90x51m<br />
30<br />
20<br />
10<br />
Ref. plane 1<br />
0<br />
0 10<br />
1.1 1.2 1.3 1.4 1.5<br />
20 30 40 50 60<br />
3.3 3.4 3.5 3.1 3.2<br />
70 80 90 100<br />
[m]<br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
Page 1/4<br />
Page 3/4<br />
Object<br />
Installation<br />
Project number<br />
Date : 18.03.2003<br />
2. Summary<br />
: Lighting Football field 90x51m<br />
: Football field 90x51m<br />
:<br />
2.1 Result overview, Reference plane No. 1<br />
Football field 90x51m - 200 <strong>Lux</strong><br />
N<br />
[m]<br />
55<br />
2.2 2.3 2.4 2.5 2.14.1<br />
4.2 4.3 4.4 4.5<br />
0<br />
1.2 1.3 1.4 1.5 1.13.1<br />
3.2 3.3 3.4 3.5<br />
0 40<br />
[m]<br />
100 150 200 250 <strong>300</strong><br />
Illuminance [lx]<br />
General<br />
Calculation algorithm used Direct part<br />
Maintenance factor 0.80<br />
Height of evaluation area 0.20 m<br />
Light spot height. [m]: 18.00 m<br />
Total luminous flux of all lamps 3600000 lm<br />
Total power 40000 W<br />
Total power per area (6100.00 m²) 6.56 W/m²<br />
Illuminance<br />
Average illuminance Eav 221 lx<br />
Minimum illuminance Emin 172 lx<br />
Maximum illuminance Emax 302 lx<br />
Uniformity g1 Emin/Em 1:1.29 (0.78)<br />
Uniformity g2<br />
Type No.\Manuf.<br />
Lanzini<br />
Emin/Emax 1:1.76 (0.57)<br />
1 20 Order no. : 24738<br />
Luminaire name : Daytona Conc. Grigio 380V<br />
Equipment : 1 x HIT-I 2000 W / 180000 lm<br />
Object<br />
Installation<br />
Project number<br />
Date : 18.03.2003<br />
: Lighting Football field 90x51m<br />
: Football field 90x51m<br />
:<br />
3.2 3D luminance distribution, Variable view<br />
Luminance on the room-surrounding surfaces:<br />
Minimum:: 6.54 cd/m²<br />
Maximum:: 16.1 cd/m²<br />
Football field 90x51m - 200 <strong>Lux</strong><br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
Page 2/4<br />
Page 4/4
Object<br />
Installation<br />
Project number<br />
Date : 15.12.2003<br />
1. Project description<br />
1.1 Floor plan<br />
Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date : 15.12.2003<br />
: Lighting Foorball field 100x68m<br />
: Football field 100x68m<br />
:<br />
3. Results artificial light<br />
3.1 Table, Illuminance, Reference plane No. 1<br />
[m]<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
: Lighting Foorball field 100x68m<br />
: Football field 100x68m<br />
:<br />
221 277 338 268 229 239 229 268 338 277 221<br />
275 348 307 <strong>300</strong> 290 274 290 <strong>300</strong> 307 348 275<br />
255 344 349 326 294 259 294 326 [349] 344 255<br />
218 308 340 324 278 249 278 324 340 308<br />
Height of the reference plane : 0.20 m<br />
Average illuminance Eav : <strong>300</strong> lx<br />
Minimum illuminance Emin : 218 lx<br />
Maximum illuminance Emax : 349 lx<br />
Uniformity g1 Emin/Em : 1 : 1.38 (0.73)<br />
Uniformity g2 Emin/Emax : 1 : 1.60 (0.63)<br />
Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />
N<br />
[m]<br />
80<br />
70<br />
60<br />
2.10 2.2 2.3 2.4 2.6 2.7 2.8 2.9 2.1 2.5<br />
4.10 4.2 4.3 4.4 4.6 4.9 4.1 4.5 4.7 4.8<br />
50<br />
Football field 100x68m<br />
40<br />
30<br />
20<br />
10<br />
Ref. plane 1<br />
0<br />
0 10<br />
1.10 1.2 1.3 1.4 1.6 1.7 1.8 1.9 1.1 1.5<br />
30 50 70<br />
3.10 3.2 3.3 3.4 3.6 3.9 3.1 3.5 3.7 3.8<br />
90 110<br />
[m]<br />
(218)<br />
255 344 349 326 294 259 294 326 349 344 255<br />
275<br />
348<br />
221 277<br />
307<br />
338<br />
<strong>300</strong><br />
268<br />
290<br />
229<br />
274<br />
239<br />
290<br />
229<br />
<strong>300</strong><br />
268<br />
307<br />
338<br />
348<br />
277<br />
275<br />
221<br />
0 10 20 30 40 50 60 70 80 90 100<br />
[m]<br />
Illuminance [lx]<br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
Page 1/4<br />
Page 3/4<br />
Object<br />
Installation<br />
Project number<br />
Date : 15.12.2003<br />
2. Summary<br />
: Lighting Foorball field 100x68m<br />
: Football field 100x68m<br />
:<br />
2.1 Result overview, Reference plane No. 1<br />
Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />
N<br />
[m]<br />
80<br />
2.10 2.5 2.1 2.2 2.3 2.4 2.6 2.7 2.8 2.94.10<br />
4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9<br />
0<br />
1.10 1.5 1.1 1.2 1.3 1.4 1.6 1.7 1.8 1.93.10<br />
3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9<br />
0 60<br />
[m]<br />
150 200 250 <strong>300</strong> 500<br />
Illuminance [lx]<br />
General<br />
Calculation algorithm used Direct part<br />
Maintenance factor 0.80<br />
Height of evaluation area 0.20 m<br />
Light spot height. [m]: 23.00 m<br />
Total luminous flux of all lamps 7200000 lm<br />
Total power 80000 W<br />
Total power per area (10560.00 m²) 7.58 W/m²<br />
Illuminance<br />
Average illuminance Eav <strong>300</strong> lx<br />
Minimum illuminance Emin 218 lx<br />
Maximum illuminance Emax 349 lx<br />
Uniformity g1 Emin/Em 1:1.38 (0.73)<br />
Uniformity g2<br />
Type No.\Manuf.<br />
Lanzini<br />
Emin/Emax 1:1.6 (0.63)<br />
1 40 Order no. : 24738<br />
Luminaire name : Daytona Conc. Grigio 380V<br />
Equipment : 1 x HIT-I 2000 W / 180000 lm<br />
Object<br />
Installation<br />
Project number<br />
Date : 15.12.2003<br />
: Lighting Foorball field 100x68m<br />
: Football field 100x68m<br />
:<br />
3.2 3D luminance distribution, Variable view<br />
Luminance on the room-surrounding surfaces:<br />
Minimum:: 4.09 cd/m²<br />
Maximum:: 18.9 cd/m²<br />
Football field 100x68m - <strong>300</strong> <strong>Lux</strong><br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
Page 2/4<br />
Page 4/4
Object<br />
Installation<br />
Project number<br />
Date : 23.05.2001<br />
1. Project description<br />
1.1 Floor plan<br />
Football field 100x60m - 500 <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date : 23.05.2001<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
3. Results artificial light<br />
[m]<br />
60<br />
40<br />
20<br />
0<br />
3.1 Table, Illuminance, Reference plane No. 1<br />
[m]<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
438 423 449 460 456 456 456 460 449 423 438<br />
458 520 592 567 538 525 538 567 592 520 458<br />
483 632 650 639 591 557 591 639 650 632 483<br />
517 631 [676] 666 603 563 603 666 676 631 517<br />
483 632 650 639 591 557 591 639 650 632 483<br />
458<br />
520<br />
438 423<br />
Height of the reference plane : 0.20 m<br />
Average illuminance Eav : 561 lx<br />
Minimum illuminance Emin : 423 lx<br />
Maximum illuminance Emax : 676 lx<br />
Uniformity g1 Emin/Em : 1 : 1.33 (0.75)<br />
Uniformity g2 Emin/Emax : 1 : 1.60 (0.63)<br />
Football field 100x60m - 500 <strong>Lux</strong><br />
592<br />
449<br />
567<br />
460<br />
538<br />
456<br />
525<br />
456<br />
538<br />
456<br />
567<br />
592 520<br />
460 449 (423) 438<br />
Football field 100x68m<br />
Ref. plane 1<br />
0 20 40 60 80 100 120 [m]<br />
1 : 2500<br />
458<br />
0 10 20 30 40 50 60 70 80 90 100<br />
[m]<br />
Illuminance [lx]<br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
N<br />
Page 1/4<br />
Page 3/4<br />
Object<br />
Installation<br />
Project number<br />
Date : 23.05.2001<br />
2. Summary<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
2.1 Result overview, Reference plane No. 1<br />
250 <strong>300</strong> 500 750 1000<br />
Illuminance [lx]<br />
General<br />
Calculation algorithm used Direct part<br />
Maintenance factor 0.80<br />
Height of evaluation area 0.20 m<br />
Light spot height. [m]: 35.00 m<br />
Total luminous flux of all lamps 16000000 lm<br />
Total power 160000 W<br />
Total power per area (9485.32 m²) 16.87 W/m²<br />
Illuminance<br />
Average illuminance Eav 561 lx<br />
Minimum illuminance Emin 423 lx<br />
Maximum illuminance Emax 676 lx<br />
Uniformity g1 Emin/Em 1:1.33 (0.75)<br />
Uniformity g2<br />
Type No.\Manuf.<br />
Lanzini<br />
Emin/Emax 1:1.6 (0.63)<br />
1 80 Order no. : 24741<br />
Luminaire name : Daytona Conc. Grigio 380V<br />
Equipment : 1 x HIT-I 2000 W / 200000 lm<br />
Football field 100x60m - 500 <strong>Lux</strong><br />
Object<br />
Installation<br />
Project number<br />
Date : 23.05.2001<br />
: Lighting Football field 100x60m<br />
: Football field 100x60m<br />
:<br />
3.2 3D luminance distribution, Variable view<br />
Luminance on the room-surrounding surfaces:<br />
Minimum:: 17.2 cd/m²<br />
Maximum:: 71.3 cd/m²<br />
Football field 100x60m - 500 <strong>Lux</strong><br />
[m]<br />
70<br />
0<br />
0 60<br />
[m]<br />
Lanzini & C. S.r.l.<br />
Lanzini & C. S.r.l.<br />
N<br />
Page 2/4<br />
Page 4/4