03.04.2013 Views

NEXIO® Ingest Control Manager - Harris Broadcast

NEXIO® Ingest Control Manager - Harris Broadcast

NEXIO® Ingest Control Manager - Harris Broadcast

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ServerS // Specialty ServerS<br />

NEXIO ® <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong><br />

<strong>Ingest</strong> Workflow and Device <strong>Control</strong> System<br />

<strong>Broadcast</strong> operations are under growing pressure to increase workflow speed and<br />

more efficiently handle the increasing volume of content. That pressure translates<br />

into one important necessity — productivity. With NEXIO ® <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong>,<br />

(ICM) <strong>Harris</strong> delivers an ingest solution for NEXIO storage area networks that achieves<br />

broadcasters’ requirements for workflow speed, capacity and productivity.<br />

Providing scheduled recording of line feeds and news services, ICM controls server<br />

channels, tape decks, routers and frame synchronizers. Device control is via Ethernet<br />

or RS-422. The application includes auto-increment of IDs, which is extremely<br />

useful in crash-record situations or when recording periodic events. Loop record,<br />

batch digitizing and sub-clipping provide additional operational benefits. ICM v2<br />

adds support for multiple NEXIO server domains, including scheduled protection<br />

records on different domains. Fast Cue and Timecode Restripe functions add speed<br />

and flexibility to your operational workflow.<br />

ICM consists of a hardware device controller and a software client application. The<br />

client can run on the device controller or on a networked PC. The system is highly<br />

versatile — it communicates as a device server via Ethernet to IP-ready hardware<br />

(such as NEXIO AMP ® servers and <strong>Harris</strong> ® X75 or X85 synchronizers), and via<br />

serial ports to other devices such as routers and VTRs. The following equipment<br />

can be controlled and monitored simultaneously from one ICM:<br />

• Up to 24 NEXIO server channels over LAN<br />

• Eight serial tape decks (VTRs) via RS-422 protocol<br />

• 16 <strong>Harris</strong> X75 or X85 synchronizers<br />

• Eight routers (up to 1024x1024)<br />

With the power of ICM, one operator can manage the ingest of multiple content<br />

feeds. Server-centric features include automated or manual recording, looping records,<br />

automatic switching, subclip creation, trims, audio input and output control,<br />

clip renaming and crash recording for fast-breaking news stories. The ability to<br />

simplify complex tasks, such as simultaneously controlling eight batch-digitizing<br />

sessions from tape, underscores the ICM solution’s power to efficiently streamline<br />

a broadcast station’s workflow.<br />

Features<br />

• Allows a single operator to control up to 24 NEXIO server channels over four<br />

separate domains<br />

• Simplifies resource management and scheduling<br />

• Enables fast and efficient ingest from tape<br />

• Automates daily, weekly and monthly feeds<br />

• Offers powerful program segmentation tools<br />

• Manages multistation ingest requirements<br />

• Includes external controller support with user-definable keys<br />

• Supports full system control via remote client software<br />

Product details<br />

eventBase Power<br />

One of the major advantages of ICM is its ability to automate the ingest of content from<br />

many sources, without human intervention. Using NEXIO ® EventBase , automated<br />

events of varying requirements (and varying sets of hardware) can be scheduled with<br />

ease. EventBase features date-driven 24/7 scheduling, with up to 1,000 events per<br />

day locked to station time for efficient, unattended operation. Every automated event<br />

can control two server channels, two VTRs, four routers, one alarm, one GPI and two<br />

proc amps (synchronizers).<br />

Additionally, audio input level controls and proc amp settings are stored within each<br />

event to ensure a quality recording every time.<br />

video Proc Amp <strong>Control</strong><br />

ICM ensures the quality of ingested content by taking full advantage of the powerful<br />

features of <strong>Harris</strong> synchronizers. In addition to automated control of up to 17 parameters,<br />

ICM provides full control of 16 X75 or X85 synchronizers. This means that virtually<br />

every function that can be performed on the synchronizer’s front panel can also be<br />

performed from the ICM user interface — with an identical front-panel view for operator<br />

familiarity. To guarantee repeatability, unlimited user settings can be saved.<br />

Program Segmentation<br />

Long server events, such as full-length programs, often need to be segmented into<br />

subclips, allowing each segment to stand alone. These subclips can then be used in the<br />

station run logs to simplify the insertion of commercials, or to simplify the editing process.<br />

ICM places powerful program segmentation tools at your command, including:<br />

• Virtual Subclips — allows users to quickly review and edit content before creating<br />

the actual subclips; also automatically segments clips into preset time intervals for<br />

faster editing<br />

• Hot Keys for Review — speeds segmenting with Auto Steps based on time blocks<br />

• Auto ID Incrementing — enables quick crash recording or repeating of an event<br />

without overwriting the previous recordings<br />

• Loop Recording — allows automated loop recordings without increasing storage<br />

To facilitate multistation ingest requirements, time-zone segmenting is also offered.<br />

This powerful feature is designed for organizations with more than one server — either<br />

locally or in different facilities. A virtual subclip text file can be distributed to other locations,<br />

where it is then imported and used to create identical subclips on other servers.<br />

ICM also applies offsets as needed, when the servers reside in different time zones.<br />

NA +1 800 231 9673 • CALA +1 786 437 1960 • EA +44 118 964 8200 • MESA +971 4 433 8250 • APAC +852 2776 0628<br />

www.broadcast.harris.com


ServerS // Specialty ServerS<br />

NEXIO ® <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong><br />

<strong>Ingest</strong> Workflow and Device <strong>Control</strong> System<br />

sPeciFications<br />

Specifications are subject to change without notice.<br />

System Configuration . . . . . Intel ® P4 3.4 GHz CPU<br />

PCI-X platform<br />

Dual mirrored 2.5-in boot drives<br />

16 RS-422 serial ports<br />

(9-pin, D-sub, female via 2 breakout panels)<br />

2 x 10/100/1000Base-T Ethernet ports<br />

4 USB 2.0 ports (2 front, 2 rear)<br />

PS/2 keyboard and mouse<br />

Windows ® XP Professional x64 Edition<br />

NEXIO <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong> software<br />

application<br />

Device <strong>Control</strong><br />

NEXIO Server Channel <strong>Control</strong> . . . Up to 24 channels total in up to 4 domains<br />

Serial <strong>Control</strong>led Devices . . . . . . . Up to 16 devices, including VTRs and router<br />

controllers<br />

Frame Synchronizers . . . . . . . . . . Up to 16 devices, including the X75 or X85,<br />

controlled via Ethernet connection<br />

Physical Characteristics<br />

1RU (H x W x D) . . . . . . . . . . . . . . 1.75 x 19 x 26.5 in. (4.4 x 48.3 x 67.3 cm)<br />

Weight . . . . . . . . . . . . . . . . . . . . 27 lbs (12.3 kg)<br />

Power<br />

Power Supply. . . . . . . . . . . . . . . . Dual hot-swappable, dual load-sharing<br />

Voltage . . . . . . . . . . . . . . . . . . . . AC 100 to 120, 200 to 240 V, auto-select<br />

Frequency . . . . . . . . . . . . . . . . . . 60/50 Hz, 8/5 A<br />

Consumption . . . . . . . . . . . . . . . . 400 W<br />

ordering inFormation<br />

NX1000ICM . . . . . . . . . . . . . . . . . <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong> includes 1 device<br />

controller and 1-seat local client license<br />

NXA1000ICM-CL . . . . . . . . . . . . . Client license for remote control of ICM server<br />

NXEC400 . . . . . . . . . . . . . . . . . . External controller<br />

NA +1 800 231 9673 • CALA +1 786 437 1960 • EA +44 118 964 8200 • MESA +971 4 433 8250 • APAC +852 2776 0628<br />

www.broadcast.harris.com<br />

©2011 <strong>Harris</strong> Corporation<br />

0311

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!