NEXIO® Ingest Control Manager - Harris Broadcast
NEXIO® Ingest Control Manager - Harris Broadcast
NEXIO® Ingest Control Manager - Harris Broadcast
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ServerS // Specialty ServerS<br />
NEXIO ® <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong><br />
<strong>Ingest</strong> Workflow and Device <strong>Control</strong> System<br />
<strong>Broadcast</strong> operations are under growing pressure to increase workflow speed and<br />
more efficiently handle the increasing volume of content. That pressure translates<br />
into one important necessity — productivity. With NEXIO ® <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong>,<br />
(ICM) <strong>Harris</strong> delivers an ingest solution for NEXIO storage area networks that achieves<br />
broadcasters’ requirements for workflow speed, capacity and productivity.<br />
Providing scheduled recording of line feeds and news services, ICM controls server<br />
channels, tape decks, routers and frame synchronizers. Device control is via Ethernet<br />
or RS-422. The application includes auto-increment of IDs, which is extremely<br />
useful in crash-record situations or when recording periodic events. Loop record,<br />
batch digitizing and sub-clipping provide additional operational benefits. ICM v2<br />
adds support for multiple NEXIO server domains, including scheduled protection<br />
records on different domains. Fast Cue and Timecode Restripe functions add speed<br />
and flexibility to your operational workflow.<br />
ICM consists of a hardware device controller and a software client application. The<br />
client can run on the device controller or on a networked PC. The system is highly<br />
versatile — it communicates as a device server via Ethernet to IP-ready hardware<br />
(such as NEXIO AMP ® servers and <strong>Harris</strong> ® X75 or X85 synchronizers), and via<br />
serial ports to other devices such as routers and VTRs. The following equipment<br />
can be controlled and monitored simultaneously from one ICM:<br />
• Up to 24 NEXIO server channels over LAN<br />
• Eight serial tape decks (VTRs) via RS-422 protocol<br />
• 16 <strong>Harris</strong> X75 or X85 synchronizers<br />
• Eight routers (up to 1024x1024)<br />
With the power of ICM, one operator can manage the ingest of multiple content<br />
feeds. Server-centric features include automated or manual recording, looping records,<br />
automatic switching, subclip creation, trims, audio input and output control,<br />
clip renaming and crash recording for fast-breaking news stories. The ability to<br />
simplify complex tasks, such as simultaneously controlling eight batch-digitizing<br />
sessions from tape, underscores the ICM solution’s power to efficiently streamline<br />
a broadcast station’s workflow.<br />
Features<br />
• Allows a single operator to control up to 24 NEXIO server channels over four<br />
separate domains<br />
• Simplifies resource management and scheduling<br />
• Enables fast and efficient ingest from tape<br />
• Automates daily, weekly and monthly feeds<br />
• Offers powerful program segmentation tools<br />
• Manages multistation ingest requirements<br />
• Includes external controller support with user-definable keys<br />
• Supports full system control via remote client software<br />
Product details<br />
eventBase Power<br />
One of the major advantages of ICM is its ability to automate the ingest of content from<br />
many sources, without human intervention. Using NEXIO ® EventBase , automated<br />
events of varying requirements (and varying sets of hardware) can be scheduled with<br />
ease. EventBase features date-driven 24/7 scheduling, with up to 1,000 events per<br />
day locked to station time for efficient, unattended operation. Every automated event<br />
can control two server channels, two VTRs, four routers, one alarm, one GPI and two<br />
proc amps (synchronizers).<br />
Additionally, audio input level controls and proc amp settings are stored within each<br />
event to ensure a quality recording every time.<br />
video Proc Amp <strong>Control</strong><br />
ICM ensures the quality of ingested content by taking full advantage of the powerful<br />
features of <strong>Harris</strong> synchronizers. In addition to automated control of up to 17 parameters,<br />
ICM provides full control of 16 X75 or X85 synchronizers. This means that virtually<br />
every function that can be performed on the synchronizer’s front panel can also be<br />
performed from the ICM user interface — with an identical front-panel view for operator<br />
familiarity. To guarantee repeatability, unlimited user settings can be saved.<br />
Program Segmentation<br />
Long server events, such as full-length programs, often need to be segmented into<br />
subclips, allowing each segment to stand alone. These subclips can then be used in the<br />
station run logs to simplify the insertion of commercials, or to simplify the editing process.<br />
ICM places powerful program segmentation tools at your command, including:<br />
• Virtual Subclips — allows users to quickly review and edit content before creating<br />
the actual subclips; also automatically segments clips into preset time intervals for<br />
faster editing<br />
• Hot Keys for Review — speeds segmenting with Auto Steps based on time blocks<br />
• Auto ID Incrementing — enables quick crash recording or repeating of an event<br />
without overwriting the previous recordings<br />
• Loop Recording — allows automated loop recordings without increasing storage<br />
To facilitate multistation ingest requirements, time-zone segmenting is also offered.<br />
This powerful feature is designed for organizations with more than one server — either<br />
locally or in different facilities. A virtual subclip text file can be distributed to other locations,<br />
where it is then imported and used to create identical subclips on other servers.<br />
ICM also applies offsets as needed, when the servers reside in different time zones.<br />
NA +1 800 231 9673 • CALA +1 786 437 1960 • EA +44 118 964 8200 • MESA +971 4 433 8250 • APAC +852 2776 0628<br />
www.broadcast.harris.com
ServerS // Specialty ServerS<br />
NEXIO ® <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong><br />
<strong>Ingest</strong> Workflow and Device <strong>Control</strong> System<br />
sPeciFications<br />
Specifications are subject to change without notice.<br />
System Configuration . . . . . Intel ® P4 3.4 GHz CPU<br />
PCI-X platform<br />
Dual mirrored 2.5-in boot drives<br />
16 RS-422 serial ports<br />
(9-pin, D-sub, female via 2 breakout panels)<br />
2 x 10/100/1000Base-T Ethernet ports<br />
4 USB 2.0 ports (2 front, 2 rear)<br />
PS/2 keyboard and mouse<br />
Windows ® XP Professional x64 Edition<br />
NEXIO <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong> software<br />
application<br />
Device <strong>Control</strong><br />
NEXIO Server Channel <strong>Control</strong> . . . Up to 24 channels total in up to 4 domains<br />
Serial <strong>Control</strong>led Devices . . . . . . . Up to 16 devices, including VTRs and router<br />
controllers<br />
Frame Synchronizers . . . . . . . . . . Up to 16 devices, including the X75 or X85,<br />
controlled via Ethernet connection<br />
Physical Characteristics<br />
1RU (H x W x D) . . . . . . . . . . . . . . 1.75 x 19 x 26.5 in. (4.4 x 48.3 x 67.3 cm)<br />
Weight . . . . . . . . . . . . . . . . . . . . 27 lbs (12.3 kg)<br />
Power<br />
Power Supply. . . . . . . . . . . . . . . . Dual hot-swappable, dual load-sharing<br />
Voltage . . . . . . . . . . . . . . . . . . . . AC 100 to 120, 200 to 240 V, auto-select<br />
Frequency . . . . . . . . . . . . . . . . . . 60/50 Hz, 8/5 A<br />
Consumption . . . . . . . . . . . . . . . . 400 W<br />
ordering inFormation<br />
NX1000ICM . . . . . . . . . . . . . . . . . <strong>Ingest</strong> <strong>Control</strong> <strong>Manager</strong> includes 1 device<br />
controller and 1-seat local client license<br />
NXA1000ICM-CL . . . . . . . . . . . . . Client license for remote control of ICM server<br />
NXEC400 . . . . . . . . . . . . . . . . . . External controller<br />
NA +1 800 231 9673 • CALA +1 786 437 1960 • EA +44 118 964 8200 • MESA +971 4 433 8250 • APAC +852 2776 0628<br />
www.broadcast.harris.com<br />
©2011 <strong>Harris</strong> Corporation<br />
0311