SAFETY DATA SHEET BERMODOL PUR 2102 - AkzoNobel

SAFETY DATA SHEET BERMODOL PUR 2102 - AkzoNobel SAFETY DATA SHEET BERMODOL PUR 2102 - AkzoNobel

akzonobel.com
from akzonobel.com More from this publisher
03.04.2013 Views

BERMODOL PUR 2102 Version 1 Revision Date 28.12.2010 Print Date 28.12.2010 GB / EN 4.3 Indication of immediate medical attention and special treatment needed Treatment : No information available. 5. FIRE-FIGHTING MEASURES 5.1 Extinguishing media Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. 5.2 Special hazards arising from the substance or mixture Specific hazards during fire fighting / Specific hazards arising from the chemical 5.3 Advice for firefighters Special protective equipment for fire-fighters : Do not allow run-off from fire fighting to enter drains or water courses. : In the event of fire, wear self-contained breathing apparatus. Further information : Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. 6. ACCIDENTAL RELEASE MEASURES 6.1 Personal precautions, protective equipment and emergency procedures Personal precautions : No conditions to be specially mentioned. 6.2 Environmental precautions Environmental precautions : Do not flush into surface water or sanitary sewer system. 6.3 Methods and materials for containment and cleaning up Methods for cleaning up / Methods for containment : Wipe up with absorbent material (e.g. cloth, fleece). Keep in suitable, closed containers for disposal. 6.4 Reference to other sections Additional advice : For personal protection see section 8. 7. HANDLING AND STORAGE 7.1 Precautions for safe handling Advice on safe handling : For personal protection see section 8. Dispose of rinse water in accordance with local and national regulations. No special handling advice required. Advice on protection against : Normal measures for preventive fire protection. fire and explosion 7.2 Conditions for safe storage, including any incompatibilities Requirements for storage : Keep container tightly closed in a dry and well-ventilated 4 / 11

BERMODOL PUR 2102 Version 1 Revision Date 28.12.2010 Print Date 28.12.2010 GB / EN areas and containers place. Advice on common storage : No special restrictions on storage with other products. Other data : No decomposition if stored and applied as directed. 7.3 Specific end uses Specific use(s) : No information available. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION 8.1 Control parameters Components with workplace control parameters Components CAS-No. Value Control parameters Diethylene glycol butylether 112-34-5 TWA Further information Further information : Indicative STEL : Indicative TWA STEL STEL: Short term exposure limit TWA: Time Weighted Average (TWA) 8.2 Exposure controls Engineering Controls Effective exhaust ventilation system 10 ppm 67.5 mg/m3 15 ppm 101.2 mg/m3 10 ppm 67.5 mg/m3 15 ppm 101.2 mg/m3 5 / 11 Update Basis Form of exposure 2006-02-09 2006-02-09 2007-08-01 2007-08-01 2006/15/EC 2006/15/EC GB EH40 GB EH40 Personal protective equipment Respiratory protection : No personal respiratory protective equipment normally required. Hand protection : For prolonged or repeated contact use protective gloves. Eye protection : Safety glasses Protective gloves complying with EN 374. Hygiene measures : General industrial hygiene practice. Environmental exposure controls

<strong>BERMODOL</strong> <strong>PUR</strong> <strong>2102</strong><br />

Version 1 Revision Date 28.12.2010 Print Date 28.12.2010 GB / EN<br />

4.3 Indication of immediate medical attention and special treatment needed<br />

Treatment : No information available.<br />

5. FIRE-FIGHTING MEASURES<br />

5.1 Extinguishing media<br />

Suitable extinguishing media : Use extinguishing measures that are appropriate to local<br />

circumstances and the surrounding environment.<br />

5.2 Special hazards arising from the substance or mixture<br />

Specific hazards during fire<br />

fighting / Specific hazards<br />

arising from the chemical<br />

5.3 Advice for firefighters<br />

Special protective equipment<br />

for fire-fighters<br />

: Do not allow run-off from fire fighting to enter drains or water<br />

courses.<br />

: In the event of fire, wear self-contained breathing apparatus.<br />

Further information : Collect contaminated fire extinguishing water separately. This<br />

must not be discharged into drains.<br />

Fire residues and contaminated fire extinguishing water must<br />

be disposed of in accordance with local regulations.<br />

6. ACCIDENTAL RELEASE MEASURES<br />

6.1 Personal precautions, protective equipment and emergency procedures<br />

Personal precautions : No conditions to be specially mentioned.<br />

6.2 Environmental precautions<br />

Environmental precautions : Do not flush into surface water or sanitary sewer system.<br />

6.3 Methods and materials for containment and cleaning up<br />

Methods for cleaning up /<br />

Methods for containment<br />

: Wipe up with absorbent material (e.g. cloth, fleece).<br />

Keep in suitable, closed containers for disposal.<br />

6.4 Reference to other sections<br />

Additional advice : For personal protection see section 8.<br />

7. HANDLING AND STORAGE<br />

7.1 Precautions for safe handling<br />

Advice on safe handling : For personal protection see section 8.<br />

Dispose of rinse water in accordance with local and national<br />

regulations.<br />

No special handling advice required.<br />

Advice on protection against : Normal measures for preventive fire protection.<br />

fire and explosion<br />

7.2 Conditions for safe storage, including any incompatibilities<br />

Requirements for storage : Keep container tightly closed in a dry and well-ventilated<br />

4 / 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!