Cmt.#<br />
A-7<br />
A-8<br />
A-9<br />
A-10<br />
Page #<br />
Line #<br />
Appendix<br />
C and F,<br />
Pg 1-3<br />
Appendix<br />
C and F,<br />
Pg 1-6<br />
Appendix<br />
C and F,<br />
General<br />
Appendix<br />
C and F,<br />
New Page<br />
or Sheet<br />
App C,<br />
Section<br />
Comment<br />
“Adherence to <strong>the</strong> LCG<br />
QC/MRL requirements was not<br />
required <strong>for</strong> this<br />
project……<strong>the</strong>re<strong>for</strong>e; corrective<br />
action was not required <strong>for</strong><br />
QC/MRL results outside <strong>the</strong><br />
LCG control limits.<br />
The last sentence should<br />
probably say “…each test panel<br />
in each sample delivery group or<br />
data package” ra<strong>the</strong>r than “in<br />
each sample”.<br />
Apparently, data qualifications<br />
were not per<strong>for</strong>med in<br />
accordance with <strong>the</strong> LCG.<br />
Tables 1 through 10 in <strong>the</strong> LCG<br />
provide explicit instruction on<br />
how <strong>the</strong> data should be qualified<br />
based upon QC outliers.<br />
Please also include <strong>the</strong> sample<br />
preparation methods, where<br />
Shaw Environmental, Inc. 8 of 39<br />
Recommendation<br />
MRLs would be required if <strong>the</strong> work<br />
was contracted to follow <strong>the</strong> LCG<br />
unless specifically stated o<strong>the</strong>rwise.<br />
Response<br />
blank and in LCS, no<br />
qualification was assigned.<br />
(i) PCBs: As shown in Table 2-<br />
2 recoveries of<br />
decafluorobiphenyl were<br />
outside <strong>the</strong> allowable limits<br />
of 50-150% <strong>for</strong> samples<br />
LL2ss-062, LL3ss-085,<br />
LL3ss-092, LL1ss-017, and<br />
LL3ss-073. Thus, <strong>the</strong><br />
results will be qualified “J”<br />
<strong>for</strong> <strong>the</strong>se samples.<br />
(j) Explosives: Samples LL3ss-<br />
088 and LL3ss-098 were<br />
extracted outside <strong>the</strong> holding<br />
time. The results of <strong>the</strong>se<br />
samples will be qualified<br />
“J”.<br />
This sentence was introduced<br />
unintentionally. The statement will<br />
be removed.<br />
Correct if applicable. For both Appendix C and F, this<br />
sentence in Section 1.3 has been<br />
revised to state: “..each test panel in<br />
each sample delivery group or data<br />
Review <strong>the</strong> LCG guidelines <strong>for</strong> <strong>the</strong><br />
qualification of analytical data.<br />
package..”<br />
The LCG guidelines <strong>for</strong> data<br />
qualification will be reviewed and a<br />
section summarizing data<br />
qualifications will be included in<br />
Appendix C and F. For text to be<br />
included in <strong>the</strong>se appendices, please<br />
see response to Comment A-6.<br />
Include. The report will be revised to include<br />
sample preparation method when