RTC <strong>for</strong> Draft LL1-4 <strong>Remedial</strong> <strong>Action</strong> <strong>Completion</strong> <strong>Report</strong><br />

Cmt.#<br />

Page #<br />

Line #<br />

Comment<br />

Verify that future trips do not have<br />

bubbles. If <strong>the</strong>se came from <strong>the</strong> lab – ask<br />

<strong>the</strong>m to QA <strong>the</strong>ir trips better.<br />

A-84 Appendices (specific) App F (A7130241) pg 4 of case narrative.<br />

The text indicates that <strong>the</strong> temperature of<br />

<strong>the</strong> cooler (upon receipt) was 12.7 degrees<br />

C. Page 16 of <strong>the</strong> report indicates that <strong>the</strong><br />

samples were not in contact with <strong>the</strong><br />

coolant. It appears that this sample was<br />

also sent via courier and may not have<br />

had time to reach <strong>the</strong> target range of 2-6<br />

degrees C. In future ef<strong>for</strong>ts, please be<br />

aware of packaging, i.e; using bubble wrap<br />

or some o<strong>the</strong>r material to prevent bottles<br />

from breaking, but also using enough ice<br />

to get <strong>the</strong> samples down to <strong>the</strong> proper<br />

temperature.<br />

A-85 Appendices (specific) In future projects, please ensure that <strong>the</strong><br />

COCs are completely filled out – ex. page<br />

775 of L0710422. Chains should have <strong>the</strong><br />

full name of <strong>the</strong> person relinquishing <strong>the</strong><br />

samples, not just initials.<br />

A-86 Appendices (specific) In future projects please ensure that <strong>the</strong><br />

proper protocol <strong>for</strong> making corrections is<br />

used, i.e. one line strikeout and initialed<br />

(ex. page 882 of L0710423).<br />

A-87 Appendices (specific) L0710819, pgs 18 and 20 indicate that <strong>the</strong><br />

surrogate or spike compound is out of<br />

range. It appears to be in range looking at<br />

<strong>the</strong> presented data.<br />

A-88 Appendices (specific) L0711004 – pg 719 indicates that <strong>the</strong><br />

samples were received out of hold time.<br />

However, <strong>the</strong> COC on pg 718 indicates<br />

that <strong>the</strong>y were received within <strong>the</strong> correct<br />

holding time.<br />

Recommendation<br />

No response required – please<br />

note <strong>for</strong> future work.<br />

No response required – please<br />

note <strong>for</strong> future work.<br />

No response required – please<br />

note <strong>for</strong> future work.<br />

No response required – please<br />

note <strong>for</strong> future work.<br />

No response required – please<br />

note <strong>for</strong> future work.<br />

Response<br />

over sampling procedure<br />

requirements <strong>for</strong> all samples with<br />

field personnel.<br />

Comment noted – we will revisit this<br />

with field crews and go over<br />

sampling procedure requirements <strong>for</strong><br />

all samples <strong>for</strong> future work. IN<br />

addition, we will ask <strong>the</strong>m lab to<br />

notify us verbally of any incident<br />

such as this so that <strong>the</strong> option of<br />

resampling is still available.<br />

Comment noted – we will revisit this<br />

with <strong>the</strong> lab <strong>for</strong> future reports and go<br />

over sampling procedure<br />

requirements <strong>for</strong> all samples with<br />

field personnel.<br />

Comment noted – we will revisit this<br />

with <strong>the</strong> lab <strong>for</strong> future reports and go<br />

over sampling procedure<br />

requirements <strong>for</strong> all samples with<br />

field personnel.<br />

Comment noted – we will revisit this<br />

with <strong>the</strong> lab <strong>for</strong> future reports and<br />

ask <strong>the</strong>m to be more diligent with<br />

<strong>the</strong>ir reporting criteria.<br />

Comment noted – we will revisit this<br />

with <strong>the</strong> lab <strong>for</strong> future reports and<br />

ask <strong>the</strong>m to be more diligent with<br />

<strong>the</strong>ir reporting criteria.<br />

A-89 Appendices (specific) In Appendix G, <strong>the</strong>re is a notation on a No response required – please Comment noted – we will revisit this<br />

Shaw Environmental, Inc. 9 of 13 June 20, 2008