NRO/CON/WT/533<br />

7.0 Excitation method Brushless excitation system (Integral<br />

exciter <strong>and</strong> rotating rectifier assembly to<br />

eliminate the need <strong>for</strong> brushes <strong>and</strong> slip<br />

rings both on exciter <strong>and</strong> motor<br />

respectively) .<br />

8.0 Automatic system power<br />

factor correction.<br />

9.0 Motor synchronism<br />

protection<br />

Motor field to have micro processor based<br />

thyristor controlled static excitation system<br />

(<strong>for</strong> automatic system power factor<br />

correction).<br />

Field monitor relay to be provided <strong>for</strong><br />

monitoring the power factor of the system<br />

which in turn trips the motor <strong>and</strong> the<br />

exciter field off if synchronism is not<br />

achieved <strong>with</strong>in a specific length of time or<br />

if the motor pulls out of step .<br />

10.0 Insulation class Class F insulation <strong>for</strong> field windings as well<br />

as <strong>for</strong> stator <strong>with</strong> temperature rise limited<br />

to 70 deg. C (as measured by resistance<br />

method) over an ambient of 50 deg. C.<br />

11.0 Locked rotor <strong>with</strong>st<strong>and</strong><br />

time<br />

Motors shall be capable of <strong>with</strong>st<strong>and</strong>ing<br />

locked rotor current <strong>for</strong> atleast 5 second<br />

longer than starting time under rated load<br />

condition.<br />

12.0 Starting method DOL / Auto trans<strong>for</strong>mer starting method /<br />

Load commutated inverter (LCI)<br />

13.0 Space Heater Space heater to be provided.<br />

EPI – New Delhi Volume-2B, Rev.0 Page 44 of 63