NRO/CON/WT/533<br />

iv) Motor body Grey iron casting as per IS:210-1978<br />

v) Casing Feet Integral <strong>with</strong> the motor frame<br />

vi) Body Design Prevent breakage or other failures due to<br />

vibrations normally encountered in heavy<br />

industries<br />

vii)<br />

Protection <strong>for</strong> Motor &<br />

Bearing<br />

IP – 55 as per IS 4691-1985.<br />

viii) Shaft Forged Steel shaft<br />

ix) Bearings (below 1000kW Anti-friction Bearing <strong>with</strong> Regreasing facility<br />

)<br />

& <strong>with</strong> grease quantity controllers<br />

Bearings (1000kW &<br />

above)<br />

x) Vibration monitor<br />

-Pedestal type sleeve bearing <strong>with</strong> <strong>for</strong>ced<br />

oil lubrication. (Arrangements to be<br />

incorporated to prevent lubricating oil from<br />

reaching the windings) -Bearing<br />

temperature, lubricating oil temperature<br />

<strong>and</strong> pressure to be measured <strong>and</strong><br />

monitored .<br />

Shall be provided at the DE end of motor<br />

bearing<br />

xi) Pedestals insulation Against circulating shaft currents<br />

xii)<br />

Hazardous Area safety<br />

design<br />

NA / as specified<br />

xiii) Indication of direction of<br />

rotation<br />

By Arrow blocks on non-driving end<br />

xiv) RTD & BTD ( PT100 type) − All motors shall be provided <strong>with</strong> Bearing<br />

(DE & NDE) temperature detectors <strong>and</strong> 6<br />

nos. stator winding temperature detectors,<br />

RTDs <strong>for</strong> monitoring alarm <strong>and</strong> trip<br />

conditions. RTD's shall be of PT100 type<br />

(duplex). − Analog input cards shall be<br />

provided in PLC <strong>for</strong> online monitoring of<br />

bearing (DE & NDE) <strong>and</strong> winding<br />

temperature of HT motors above 1000 KW .<br />

− For HT motors, temperature of each RTD<br />

(<strong>for</strong> winding / bearing) shall be wired to<br />

PLC system <strong>and</strong> limit value contacts <strong>for</strong><br />

alarm <strong>and</strong> tripping shall be generated in the<br />

PLC along <strong>with</strong> the display of all parameters<br />

of the motor including the winding <strong>and</strong><br />

bearing temperature.<br />

xv) Vibration monitoring − Vibration monitoring (online) shall be<br />

provided at the DE end of motor bearing <strong>for</strong><br />

motors of ratings 1000 kW <strong>and</strong> above <strong>and</strong><br />

it should be connected to PLC <strong>for</strong> online<br />

monitoring .<br />

xvi) Paint shade − Light grey , shade no. 631 as per IS 5<br />

3.0 Terminal box<br />

i) Protection IP -55<br />

ii) Type Phase segregated<br />

EPI – New Delhi Volume-2B, Rev.0 Page 42 of 63