NRO/CON/WT/533<br />

2) Pumps speed shall be 1500 rpm. Electrical motor pump shall have<br />

25% reserve power over <strong>and</strong> above required <strong>for</strong> operating the<br />

pump at working pressure <strong>and</strong> flow.<br />

3) The number of st<strong>and</strong>by pumps shall be as follows:<br />

Up to 3 nos. working pumps : 1 no.<br />

st<strong>and</strong>by<br />

For 4 to 6 nos. working pumps : 2 nos.<br />

st<strong>and</strong>by<br />

4) The following cleanliness level of oil shall be maintained <strong>for</strong><br />

hydraulic systems:-<br />

Systems <strong>with</strong>out servo valves/ proportional valves:<br />

NAS.7.<br />

Systems <strong>with</strong> proportional valves: NAS.5.<br />

Systems <strong>with</strong> servo valves: NAS.4.<br />

5) All filters shall have ß ratio ≥ 200. the fineness of various filters<br />

shall be as follows:<br />

Hydraulic systems <strong>with</strong>out | Pressure line filters : 10micron<br />

proportional <strong>and</strong> servo valves | Circulat ion f ilters : 10 micron<br />

Return line filters : 10 micron<br />

6) The capacity of pressure line, circulation filters, return line filters<br />

shall be as follows:-<br />

a. Return line filters : 3 times of maximum return flow or<br />

3 times of maximum pump flow<br />

whichever is greater at ∆ p= 0.5 bar<br />

(total) in clean condition.<br />

b. Circulation filters : pump flow at ∆ p= 0.5 bar in<br />

clean condition.<br />

c. Pressure line : 2 to 2.5 times pump flow at ∆ p= 0.8<br />

filters<br />

bar in clean condition.<br />

All the filters shall be of absolute filtration design.<br />

7) Solenoid coil voltage shall be 24 VDC<br />

8) First fill of oil shall be in the bidder scope of supply.<br />

The specification of hydraulics as indicated above shall be applicable <strong>for</strong><br />

hydraulic drives of wagon tippler, side arm charger, stacker <strong>and</strong> bucket<br />

wheel reclaimer.<br />