<strong>Enquiry</strong> <strong>Specification</strong> <strong>for</strong> <strong>Wagon</strong> <strong>Tippler</strong> <strong>with</strong> <strong>Side</strong> <strong>Arm</strong> <strong>Charger</strong> <strong>and</strong> Associated works<br />

NRO/CON/WT/533<br />

5.0 HYDRAULICS<br />

(A) Facilities to be provided in the Hydraulic Power Pack Room.<br />

Hydraulic power pack shall be installed in room where adequate provisions are<br />

made to keep ambient air free from dust, moisture <strong>and</strong> ambient temperature<br />

shall be kept below 35 0 C.<br />

Adequate facility shall be provided <strong>for</strong> h<strong>and</strong>ing of equipments/ components<br />

installed in the power pack room.<br />

Adequate illumination.<br />

Adequate fire alarms, fire protection system <strong>and</strong> fire fighting facilities.<br />

Antiskid title floor shall be provided in the power pack room.<br />

Design of floor shall be such that spilled oil / leakage oil, if any is collected into<br />

drain pit <strong>and</strong> from there, arrangement shall be provided <strong>for</strong> collection <strong>and</strong><br />

disposal of leakage oil into oil barrels <strong>for</strong> reclamation purpose.<br />

Emergency doors <strong>and</strong> Adequate space to carry out maintenance activities.<br />

Hydraulic circuit of the system on anodized plate(s) shall be provided.<br />

(B) Whatever Servo / Proportional Valves are used in the system, supplier shall<br />

supply Servo Valve flushing facility <strong>and</strong> test kits <strong>for</strong> Servo <strong>and</strong> Proportional<br />

Valves.<br />

(C) For hydraulic systems <strong>with</strong> conventional valves, the supply voltage to various<br />

controls shall be 24 DC.<br />

(D) BSP’s approved preferred make in vogue shall be followed.<br />

(E) Mineral oil shall be used in hydraulic systems until otherwise agreed upon by<br />

BSP.<br />

(F) All the pipes <strong>and</strong> fittings used in hydraulic systems of critical production units<br />

shall be stainless steel until otherwise agreed up on by BSP.<br />

(G) Filters shall be provided <strong>for</strong> continuous removal of contaminants from the<br />

hydraulic fluid, which are likely to cause malfunction of pumps, valves <strong>and</strong><br />

actuators <strong>and</strong> maintain desired cleanliness level of hydraulic fluid. Adequate<br />

filtration shall be provided <strong>for</strong> each system considering the ingress rate of<br />

contaminants in each applications.<br />

(H) All the pressure line, return line <strong>and</strong> circulation filters shall be of absolute<br />

filtration design <strong>with</strong> B (x) ratio greater than or equal to 200. Total delta p across<br />

filters shall not exceed 0.5 bar <strong>with</strong> filter element in clean condition. (Total p<br />

means pressure drop across clean filter element plus pressure drop filter<br />

housing).<br />

The micron rating shall be as specified in T.S. <strong>for</strong> individual filters.<br />