Summary<br />

• Full-size <strong>pellicle</strong>s fabricated with membrane thickness of<br />

70%. Expected <strong>transmission</strong> is 61% double pass<br />

• New process developed to achieve near-best <strong>transmission</strong> of<br />

67% on small-size samples with tensile membrane stress.<br />

• Thermal model completed & shows that CTE compatible mesh<br />

+ Si membrane is necessary to avoid differential thermal<br />

expansion related issues.<br />

• Scan test with in-house scanner shows <strong>pellicle</strong> robustness at<br />

repeated 6G acceleration with peak velocities of 2m/s.<br />

Future work<br />

• Vibration test to satisfy zero-particle adder criteria<br />

• Full-scale <strong>pellicle</strong> for 70% double-pass txm<br />

"<strong>EUVL</strong> Pellicle Development", Yashesh Shroff, Pei-Yang Yan, F. Salamassi, Eric Gullickson<br />

<strong>EUVL</strong> Symposium 2008, Lake Tahoe 22