<strong>Affirma</strong> <strong>Spectre</strong> <strong>DC</strong> <strong>Device</strong> <strong>Matching</strong> <strong>Analysis</strong> <strong>Tutorial</strong><br />

Annotation parameters<br />

25 annotate=sweep<br />

Degree of annotation. Possible values are no, title, sweep, status, or steps.<br />

26 stats=no<br />

<strong>Analysis</strong> statistics. Possible values are no or yes.<br />

27 title<br />

<strong>Analysis</strong> title.<br />

The dcmatch analysis will find a dc operating point first. If the dc analysis fails,<br />

then the dcmatch analysis will fail also. The parameter mth is a threshold value<br />

relative to the maximum contribution. Any device contribution less than (mth *<br />

maximum) will not be reported. Where maximum is the maximum contribution<br />

among all the devices of a given type.<br />