A=2⋅(T+0,5⋅t+d)+S<br />
A - stud bolt length exclusive of negative length<br />
tolerance, m<br />
T – flange thickness, m<br />
t – plus tolerance for flange thickness, m<br />
d – nut thickness (equals nominal bolt<br />
diameter), m<br />
S – flange face standoff (for BX<br />
assemblies it is zero), m<br />
n – negative tolerance on bolt length :<br />
1,5875 mm (1/16") for lengths up to 304,8<br />
mm (12"); 3,175 mm (1/8") for lengths over<br />
304,8 mm (12") to 457,2 mm<br />
(18"); 6,35 mm (1/4") for lengths over<br />
457,2 mm (18"), m