Power Cables<br />

Appendix Tables<br />

The latest editions <strong>of</strong> the following st<strong>and</strong>ards should be considered where<br />

appropriate along with other relevant international or national st<strong>and</strong>ards as<br />

consistent with good UK engineering practices:<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

IEC 60228 – Conductors <strong>of</strong> insulated cables;<br />

IEC502 – Extruded solid dielectric insulated power cables for rated voltages<br />

from 1kV up to 30kV;<br />

IEC60840 Tests for power cables with extruded insulation for rated voltages<br />

above 30kV (Um = 36kV) up to 150kV (Um = 170kV);<br />

IEC 60885-3 – Partial discharge tests;<br />

IEC 287 – Calculation <strong>of</strong> continuous current rating <strong>of</strong> power cables<br />

(100% load factor);<br />

IEC 853 – Calculation <strong>of</strong> cyclic <strong>and</strong> emergency current rating <strong>of</strong> cables;<br />

BS 1441 – Galvanised steel wire for submarine cables;<br />

ENATS 09-16 – Tests on power cables with XLPE insulation <strong>and</strong> metallic<br />

sheath <strong>and</strong> their accessories, for rated voltages <strong>of</strong> 66kV (Um = 72.5kV), 110kV<br />

(Um = 123kV) <strong>and</strong> 132kV (Um = 145kV);<br />

CEGB – TDM 99/45 <strong>and</strong> 99/56;<br />

ICEA S68 516 – Ethylene propylene rubber insulated wire <strong>and</strong> cable for the<br />

transmission <strong>and</strong> distribution <strong>of</strong> electrical energy;<br />

AEIC CS6-87 or 96 – Specifications for ethylene propylene rubber insulated<br />

shielded power cables rated 5kV through 69kV;<br />

BS 6469 – Insulating <strong>and</strong> sheath materials <strong>of</strong> electric cables;<br />

ER 55/4 – Bonding systems; <strong>and</strong><br />

ERA Report F/T 186 – Power cable ratings.<br />

Optical Fibre Cables<br />

The latest editions <strong>of</strong> the following st<strong>and</strong>ards should be considered where<br />

appropriate along with other relevant international or national st<strong>and</strong>ards as<br />

consistent with good UK engineering practices:<br />

●<br />

●<br />

●<br />

●<br />

●<br />

IEC 793-1 Optical fibres part 1: Generic specification;<br />

IEC 793-2 Optical fibres part 2: Product specification;<br />

IEC 794-1 Optical fibre cables part 1: Generic specification, measurements<br />

<strong>and</strong> tests;<br />

IEC 794-2 Optical fibre cables part 2: Product specification;<br />

IEC 1073 -1 Splices for optical fibres <strong>and</strong> cables part 1: Generic specification;<br />