27.03.2013 Views

Scana Skarpenord AS Complete set of datasheets - Net

Scana Skarpenord AS Complete set of datasheets - Net

Scana Skarpenord AS Complete set of datasheets - Net

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Control Circuit d36<br />

Indirect Volumetric indication<br />

CONTROL CIRCUIT D36<br />

INDIRECT VOLUMETRIC INDICATION<br />

Temperature and pressure independent<br />

P<br />

T<br />

T<br />

A B<br />

T0<br />

CL OP<br />

TEMPERATURE AND PRESSURE INDEPENDENT<br />

P<br />

T<br />

PRESSURE LINE lINE<br />

RETURN LINElINE<br />

ISOlATEd ISOLATED VOLUME VOlUmE<br />

ElECTRIC ELECTRIC SIGNAL SIgNAl<br />

ClOSINg CLOSING<br />

LOCKED lOCkEd OPENING OPENINg<br />

Throttle control, fail to <strong>set</strong>. Indirect indication. Pressure and temperature independent.<br />

Control via spring loaded directional valve, 6/3 type, activated by two solenoids operated by electric signals.<br />

Upon release <strong>of</strong> electric signal to the solenoid, the pressure in the lines from the actuators is drained to tank.<br />

T P<br />

A hydrolock with built in relief valves is mounted on the actuator, and maintains the position <strong>of</strong> the valve when the control<br />

lines are drained. The relief valve prevents accumulation <strong>of</strong> high pressure in the actuator lines due to temperature<br />

changes.<br />

Continuous indication <strong>of</strong> the valve position is achieved by a potentiometer connected to a piston type volumetric indicator<br />

mounted in the solenoid valve cabinet. The volumetric indicator has a visual indicator in front for local indication <strong>of</strong> the<br />

valve position.<br />

The volumetric indicator is connected to the return line from actuator, and not exposed to variations in pressure. When<br />

the circuit is not activated, the indicator is isolated from the lines, and not influenced by volume variations due to pressure<br />

changes. If the volumetric indicator for some reason is not synchronised with the actuator, the indicator will automatically<br />

be synchronised with the actuator each time the valve is operated from one end position to the other.<br />

<strong>Scana</strong> <strong>Skarpenord</strong> <strong>AS</strong> • Såheimsveien 2, P.O. Box 3 • N-3661 Rjukan, Norway<br />

Tel: +47 35 09 32 00 • Fax: +47 35 09 18 01 E-mail: ssr@scana.no • www.scana.no<br />

A<br />

B<br />

T0<br />

CL OP<br />

P<br />

T<br />

T<br />

A B<br />

T0<br />

CL OP

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!