CSPLAN 351<br />

• A PLAN subcommand is required that specifies a file whose specifications are to be displayed.<br />

Operations<br />

• If a sample design is created the procedure automatically writes a suitable analysis design<br />

to the plan file. The default analysis design specifies stratification variables and cluster<br />

variables for each stage as well as an estimation method appropriate for the chosen extraction<br />

method.<br />

• CSPLAN writes design specifications in XML format.<br />

• By default CSPLAN displays output that summarizes the sample or analysis design.<br />

<strong>Syntax</strong> Rules<br />

General<br />

• PLAN, PLANVARS, and PRINT are global. Only a single instance of each global subcommand<br />

is allowed.<br />

• Within a subcommand an error occurs if a keyword or attribute is specified more than<br />

once.<br />

• Equals signs shown in the syntax chart are required.<br />

• Subcommand names and keywords (e.g., PPS_WR) must be spelled in full.<br />

• In general empty subcommands (i.e., those that have no specifications) generate an error.<br />

DESIGN is the only subcommand that can be empty.<br />

• Any variable names that are specified must be valid SPSS variable names.<br />

Creating a Plan<br />

• Stages are specified in design blocks. The DESIGN subcommand signals the start of a<br />

block. The first block corresponds to stage 1, the second to stage 2, and the third to stage<br />

3. One DESIGN subcommand must be specified per stage.<br />

• The following subcommands are local and apply to the immediately preceding DESIGN<br />

subcommand: METHOD, MOS, SIZE, RATE, STAGEVARS, ESTIMATOR, POPSIZE, IN-<br />

CLPROB. An error occurs if any of these subcommands appears more than once within a<br />

block.<br />

• Available METHOD and ESTIMATOR options depend on the stage.<br />

• The following subcommands are honored only if a sample design is requested: METHOD,<br />

MOS, SIZE, RATE, and STAGEVARS. An error occurs if any of these subcommands is specified<br />

for an analysis design.<br />

• MOS can be specified in stage one only.