27.03.2013 Views

SPSS® 12.0 Command Syntax Reference

SPSS® 12.0 Command Syntax Reference

SPSS® 12.0 Command Syntax Reference

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

322 CROSSTABS<br />

ALL All cell information. This includes cell counts; row, column, and total percentages;<br />

expected counts; residuals; standardized residuals; and adjusted standardized<br />

residuals.<br />

NONE No cell information. Use NONE when you want to write tables to a procedure<br />

output file without displaying them (see the WRITE subcommand on p. 325).<br />

This is the same as specifying NOTABLES on FORMAT.<br />

STATISTICS Subcommand<br />

STATISTICS requests measures of association and related statistics. By default, CROSSTABS<br />

does not display any additional statistics.<br />

• STATISTICS without keywords displays the chi-square test.<br />

• If STATISTICS is specified with keywords, CROSSTABS calculates only the requested<br />

statistics.<br />

• In integer mode, values that are not included in the specified range are not used in the<br />

calculation of the statistics, even if these values exist in the data.<br />

• If user-missing values are included with MISSING, cases with user-missing values are<br />

included in the calculation of statistics as well as in the tables.<br />

CHISQ Display the Chi-Square Test table. Chi-square statistics include Pearson chisquare,<br />

likelihood-ratio chi-square, and Mantel-Haenszel chi-square (linearby-linear<br />

association). Mantel-Haenszel is valid only if both variables are<br />

numeric. Fisher’s exact test and Yates’ corrected chi-square are computed for<br />

all 2 × 2 tables. This is the default if STATISTICS is specified with no<br />

keywords.<br />

PHI Display phi and Cramér’s V in the Symmetric Measures table.<br />

CC Display contingency coefficient in the Symmetric Measures table.<br />

LAMBDA Display lambda (symmetric and asymmetric) and Goodman and Kruskal’s<br />

tau in the Directional Measures table.<br />

UC Display uncertainty coefficient (symmetric and asymmetric) in the Directional<br />

Measures table.<br />

BTAU Display Kendall’s tau-b in the Symmetric Measures table.<br />

CTAU Display Kendall’s tau-c in the Symmetric Measures table.<br />

GAMMA Display gamma in the Symmetric Measures table or Zero-Order and Partial<br />

Gammas table. The Zero-Order and Partial Gammas table is produced only<br />

for tables with more than two variable dimensions in integer mode.<br />

D Display Somers’ d (symmetric and asymmetric) in the Directional Measures<br />

table.<br />

ETA Display eta in the Directional Measures table. Available for numeric data<br />

only.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!